_

brJ March 14, 1986 EN 86-13 N

OFFICE OF INSPECTION AND ENFORCEMENT

~

NOTIFICATION OF SIGNIFICANT ENFORCEMENT ACTI_0_N F

Licensee: Comonwealth Edison Company (LaSalle County riuclear Power Station)

Docket No. 50-374

Subject:

PROPOSED IMPOSITION OF CIVIL PENALTY - $50,000 This is to inform the Commission that a Notice of Violation and Proposed Imposition of Civil Penalty in the amount of Fifty Thwsand Dollars ($50,000) i will be issued on or about March 19, 1986 to Commonwealth Edison Company. The l

action involves the failure by the licensee to properly evaluate emergency core cooling system (ECCS) Divisicn 1 operability after closing the low pressore coolant injection minimum flow valve to perform maintenance. Since Division 3, which consists of the high pressure core spray system, hcd already been declared inoperable-by the licensee, this resulted in two ECCS divisions being inoperable at the same time.

By the time that one of the divisions was restored to operable status, two divisions of ECCs had been inoperable for more than 13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br /> without action being initiated to restore one of the inoperable divisions to operable status or to meet the requirements of the applicable Technical Specification action statement.

It should be noted that the licensee has not been specifically informed of the enforcement action. The Regional Administrator has been authorized by the i

Director, Office of Inspection and Enforcement, to sign this action. The J

schedule of issuance and notification is:

Mailing of Notice March 19, 1986 Telephone Notification of Licensee March 19, 1986,

i A news release has been prepared and will be issued about the time the i

licensee receives the Notice. The State of Illinois will be notified.

The licensee has thirty days from the date of the Notice in which to respond.

l Following NRC evaluation of the response, the civil penalty may be remitted, mitigated, or imposed by Order.

j Contact T. Poindexter, IE 29635 J. Axelrad, lE 24909 Distribution:

f5' 3

G2 o H Street L// b MNBB8 W J Phillips k /.

Willste f!

//

Chairman Palladino EDO NRR IE NMSS Comm. Roberts D[D/ROGR OIA RES Comm. Asselstine P6 01 Comm. Bernthal ELD AE0D Comm. Zech RM g/

Air Rights b k7/7 ACRS SECY Regi9nal Offices MAIL CA SP RI /#.00 RIV V 5 0 0 ADM: Doc. Mgt. Br.

PE RII y5otRV U f oo POR I

III 450o PRELIMINARY INFORMATION - NOT FOR PUBLIC DISCLOSURE UNTIL MA.RCH 19, 1986 8603200028 8603:4

/6;3.3 PDR I&E EN-86-013 PDR

, _ -.