Responds to NRC Re Violations Noted in Insp on 850715-17.Corrective Actions:Changing of Reactor Ventilation Sys Absolute Filter Added to Planned Maint Schedule & Charter for Reactor Safeguards Committee Modified
ML20138A173
Person / Time
Site: Washington State University
Issue date: 09/19/1985
From: Wilson W
WASHINGTON STATE UNIV., PULLMAN, WA
To: Scarano R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
Shared Package
ML20138A153 List:
References
NUDOCS 8510080475
Download: ML20138A173 (6)


Text

-

WASHINGTON STATE UNIVERSITY Meavto PULLMAN, WASHINGTON 99 n i3oo UC NUCLEAR RADIATION CENTER 5 SFP 23 a p,

September 19, 1985 E L,';v;;c Ross A. Sarno, Director Division of Radiological Safety and Safeguards Programs U.S. Nuclear Regulatory Commission, Region V 1450 Maria Lane, Suite 210 Walnut Creek, California 94596

Dear Mr. Sarno:

In response to the Notice of Violation resulting from the inspection conducted by Mr. M. Cillis on July 15-17, 1985, the following responses are provided to the three identified violations labeled A, B, and C in your letter.

A.

Ventilation System Absolute Filter. The changing of the reactor ventilation system absolute filter has been added to the facility planned maintenance schedule and will automatically be changed at the scheduled time.

In addition, a sticker system is being initiated to indicate when this and all obsolete filters in the Radiation Center are changed.

A filter change procedure is in the process of being written in cooperation with the Radiation Safety Office for changing obsolete filters.

This procedure will be completed by October 31, 1985.

The above-mentioned steps will preclude this violation from occurring again.

Full compliance will be achieved upon final approval of the obsolete filter change procedure which will occur by October 31, 1985.

B.

Standard Procedure Review.

The charter for the Reactor Safeguards Committee has been modified to clearly indicate the requirement for the committee's biennial review of all standard procedures, the facility emergency plan, and the facility security plan. The Reactor Safeguards Committee is scheduled to meet on September 26, 1985 for the purpose of reviewing the above-mentioned procedures and plans.

The above-mentioned change to the Committee's charter should preclude the reoccurrence of this violation.

Full compliance will be achieved by October 1,1985 on this matter.

C.

Operator Requalification Program. The existing SR0 activity record system did not make a distinction between direct and indirect supervision.

The facility operating procedure has been modified as indicated in the attached information to distinguish between direct and indirect supervision in the operating log.

0510080475 051004 PDR ADOCK 05000027 G

PDR

Ross A. Sarno, Director September 19, 1985

'Page Two The above-mentioned procedure should preclude the reoccurrence of this violation.

F_ull compliance will be achieved after the new activity logging procedure will have been in effect for one calendar quarter which will occur on January 1, 1986.

Sincerely, W.9V4 W.E. Wilson Associate Director -

WEW:mb

' WASHINGTON STATE UNIVERSITY PULLMAN, WASHINGTON 99168-1300 NUCLEAR RADIATION CENTER MEMORANDUM TO

John Sheppard, Chairman RSC FROM : W.E. Wilson, Associate Director, NRC N. [ k DATE : July 17,1985 RE
Reactor Safeguards Committee Charter Enclosed is a draft revision of the charter for the Reactor Safe-guards Committee, including the new requirements established by the new facility license of August 11, 1982. The major change is the requirement for the biennial review of all standard procedures, the facility emergency plan, and the facility security plan.

WEW:mb

4/ A G 111 N G T O N GTATC

t. y N 1 v n yt n y T 9,'

PULLMAN, b/ A S H I N G T O M 99164-1300 NUCLEAR R ADI ATION CENTER MEMORANDUM V. E. VILSON, ASSOCI ATC DIRECTOR TO FROM

- JERRY A. NEIDICER, REACTOR SUPERVISOF DATE

SEPT. 17, 1985 SUBJECT : N.R.C. VIOLATIONS The following corrective action will be taken for items given below to insure there will be no future conflict with our Technical Specifications:

Ventilation System Filters:

The changing of the Reactor Ventilation System absolute filters will be incorporated into our Planned Maint enance Schedule, to be completed at a specific time and interval. In addition,. n sticker system will be initiated which will be attached to the filter housing, indicatinD change due date.

Rector Senior Operator Supervision:

To indicate when the acting S.R.O. is directly supervising the Rer.ctor Operator, a suall block next to the SRO column on the Reactor Log sheet, marked ' D ',

w!!! be checked when the SRO is directly supervisina.

Rector Check-outs, when directly supc-rvised by the SRO, will be noted no in the comments section.

Presently, I am consulting with the Radiation f',nfety Officer on a procedure for changing the Ventilation System Absolute Filt ers VEV:jn 1

(New section added to SUP #4 - Standard Startup and Operating Procedure)

E.

Logging of SR0 Direct Supervision Each entry line in the Operations Log Sheet in the SR0 column shall indicate if the SR0 was present in the control room or pool room during the period covered by the entry. The format of the entry shall be SR0/D if the SR0 is present to indicate direct supervision and where SR0 is the initials of the supervisor.

If the supervisor is not present, only the initials of the SR0 will be recorded.

NRC Form No. 36 9/85 QUARTERLY REACTOR OPERATOR / SUPERVISOR ACTIVITY REPORT E

TO

W.E. bilson FROM
JERRY A. NEIDIGER.

Quarter Year SUBJECT : Quarterly Reactor' 0peration/ Supervision Activity Report for:

I During the past quarter, the above-named individual has actively engaged j

in the operation and/or supervision of the W.S.U. TRIGA reactor facility to j

the extent listed below.

Required SR0 R0 4

1.

Number of checkouts performed 1

1 or 2.

Number of checkouts supervised 1

i 3.

Hours of reactor operation 20 10 or 4.

Hours of direct operations supervision 20 i

5.

Number of pulses performed 1

1 or 6.

Number of pulses directly supervised 1

Based on the licensed activity of the above-named individual, it is

).

deemed that he/she has/has not fulfilled the quarterly reactor operation requirements stipulated in the requalification program.

W.E. Wilson, Associate Director a