ML20137Z669

From kanterella
Jump to navigation Jump to search
Suppls 790202 Response to IE Bulletin 78-14 & Response to IE Bulletin 80-14.Preventive Maint Program Includes Monitoring of Scram Pilot Valves,Backup Scram Pilot Valves, Discharge Vol Solenoid Valves & Discharge Vol Test Valves
ML20137Z669
Person / Time
Site: Monticello 
Issue date: 02/25/1986
From: Larson C
NORTHERN STATES POWER CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
IEB-78-14, IEB-80-14, NUDOCS 8603130091
Download: ML20137Z669 (2)


Text

'

o Northern States Power Company 414 Nicollet Mall Minneapohs, Minnesota 55401 Telephone (612) 330 5500 February 25, 1986 Mr James G Keppler Director - Region III Office of Inspection and Enforcement U S Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 MONTICELLO NUCLEAR GENERATING PLANT Docket No. 50-263 License No. DPR-22 Supplemental Response to IE Bulletin 78-14 The following information concerning the Monticello Nuclear Generating Plant is reported as an update to our February 2, 1979 letter in accordance with Item 4 of IE Bulletin 78-14.

Paragraph 2 of the February 2, 1979 letter references two tables which describe the projected preventive maintenance periods as of February 2, 1979.

Because of plant modifications required in IEB 80-14, Degradation of BWR Scram Discharge Volume Capability, and additional preventive maintenance conducted in parallel with the 1984 Recirculation Piping Replacement Project, the previously submitted schedules are obsolete.

The preventive maintenance activities associated with the following valves shown in the referenced tables will be monitored and controlled in the future using the plant's preventive maintenance program:

1.

Scram Pilot Valves 2.

Back-up Scram Pilot Valves 3.

Discharge Volume Solenoid Valves 4.

Discharge Volume Test Valve As before, this program will assure that all critical parts are replaced at frequencies consistent with General Electric reco mnendations and plant scram valve operational and maintenance history. This will be a five-year replacement frequency for all elastomeric valve parts. Our preventive maintenance program will assure that the combined shelf and in-service life is no longer than seven years. We believe that our preventive maintenance program provides adequate control of scram valve maintenance and we do not believe it is necessary to maintain the referenced tables current.

( (\\

8603130091 g6022 ADOCK 0 % 263 l

PDR g

/0 a

MAR 7 1986

Y, T

. yo

.e c.

J q K ppl r

' February 25, 1986 Page 2 Northem States Power Company Please contact us if you have any questions related to the supplemental information we have provided.

m C E Larson Vice President Nuclear Support Services c: Document Control Desk, NRC NSS Project Manager, NRC i

G Charnoff l

l i

l l

l l

1 i

j

-