ML20137Z459

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp of License IRO62-09
ML20137Z459
Person / Time
Issue date: 04/18/1997
From: Caniano R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Barnes S
DESERT INDUSTRIAL X-RAY, INC.
References
NUDOCS 9704240178
Download: ML20137Z459 (1)


Text

,

Dcb April 18,1997 Stephen L. Barnes President Desert Industrial X-Ray, Inc.

7408 Andrews Highway Odessa, TX 79765

SUBJECT:

NOTICE OF VIOLATION DATED FEBRUARY 7,1997

Dear Mr. Barnes:

This acknowledges receipt of your letter dated April 4,1997, in response to our letter dated February 7,1997, transmitting a Notice of Violation.

We have reviewed your corrective actions, which appear to be adequate, and have no further questions at this time. These corrective actions will be examined during a future inspection.

Sincerely, 4

driginal Signtfd by Roy 1 Caulano 4

Roy J. Caniano, Acting Director Division of Nuclear Materials Safety License No.: New Mexico IR062-09 Docket No.: 150-00030 bec w/Itr dtd 04/04/97: PUBLIC i

DOCUMENT NAME: G :\\LTRS 2 LIC\\MTL S\\030\\ 97100030. LO 1 Ta receive a copy of this document. Indicate in the box.

"C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy OFFICE DNMS/Rlli c.

DNMS/Riil

,W DNMS/Rll!

l NAME HAYS / jaw 6@

l@J4jgEfPS 1_CANIANO g,Vu R

DATE 04h/97 (T4/f8/97 04///97

(/

OFFICIAL RECORD COPY 1

9704240178 970418 PDR STPRO ESGNN

(

l I.ll1.1 I.l I.ll.l,Illi, I.li

=

l gq

..=.

re 4

DESERT INDUSTRIAL X-RAY, INC.

7408 ANDREWS HIGHWAY ODESSA, TX 79765 (915) 363-0669 FAX--(915) 363-0929 April 4, 1997 Mr. Monte P. Phillips, Chief Nuclear Materials Inspection Branch 2 Division of Nuclear Materials Safety U. S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C.

20555 Re: Reply to Notice of Violation

Dear Mr. Phillips:

At the time the violation occurred, the records pertaining to the rate meter calibrations were being moved to our office in Arkansas.

This made it difficult to monitor the expiration date of the rate meters being used by our out of state radiographers.

When I

was notified that the radiographers rate meter was out of calibration, I immediately over-night Fed-Exed a

properly calibrated rate meter to the radiographer.

The radiographer was also reprimanded for not more closely monitoring his rate meter calibration due date since our survey reports contain a space for recording that date.

As of July, 1996, I vacated my New Mexico license and all my records have been moved to our Odessa, Texas office.

All the records are maintained in one office, and are overseen by one person; the Radiation Safety Officer for my Texas license.

]

Full compliance to 10 CFR 2.201 was achieved in July, 1996 by centrally locating all of the company records.

This should insure that this violation never re-occurs.

Sincerely, Ste en L. Barnes President' New Mexico License No.

IR062-09 Texas License No. LO4590 UWkS

,