ML20137Z144
| ML20137Z144 | |
| Person / Time | |
|---|---|
| Site: | Maine Yankee |
| Issue date: | 10/03/1985 |
| From: | Whittier G Maine Yankee |
| To: | Butcher E Office of Nuclear Reactor Regulation |
| References | |
| 6483L-SDE, GDW-85-251, MN-85-171, NUDOCS 8510080179 | |
| Download: ML20137Z144 (1) | |
Text
EDISON DRIVE MAIRE HARHEE 'ATOMICPOWERCOMPARUe avausra. uaunE o< ass
{ap,,
(207) 623-3521 g
October 3, 1985 MN-85-171 GDW-85-251 Director of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, D. C.
20555 Attention:
Mr. Edward J. Butcher, Jr.
Acting Branch Chief Operating Reactors Branch No. 3 Division of Licensing
Reference:
(a) License No. OPR-36 (Docket No. 50-309)
Subject:
Steam Generator Tube Surveillance Gentlemen:
Maine Yankee's Technical Specification 4.10.E.1 requires that, following each inservice inspection of steam generator tubes, the number of tubes plugged in each steam generator shall be reported to the Commission within 15 days.
Please be advised that between September 20-24, 1985, the number of tubes that were plugged per steam generator were as follows:
Steam Generator Nunber of Tubes Plugged E-1-1 3
E-1-2 22 E-1-3 11 Additional information related to the inspection of the steam generators will be included in our Inservice Inspection Report which is scheduled to be submitted in January,1986.
Please contact us if you have any questions.
Very truly yours, MAINE YANKEE ATOMIC POWER COWANY 8510080179 851003 PDR ADOCK 05000309 Q
. D. Whittler, Manager Nuclear Engineering & Licensing GDW/bjp cc: Dr. Thomas E. Murley
- 00i Mr. Cornelius F. Holden l
6483L-SDE