ML20137Y282

From kanterella
Jump to navigation Jump to search
Application for Amend to License DPR-34,allowing Replacement of Mechanical Snubbers W/Hydraulic Snubbers & Vice Versa
ML20137Y282
Person / Time
Site: Fort Saint Vrain 
Issue date: 12/06/1985
From: Walker R
PUBLIC SERVICE CO. OF COLORADO
To:
Shared Package
ML20137Y276 List:
References
NUDOCS 8512110008
Download: ML20137Y282 (3)


Text

'

BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION

'In the Matter of the Facility Operating License)

)

of

)

Docket No. 50-267

)

PUBLIC SERVICE COMPANY OF' COLORADO

)

Application for Amendment to Appendix A of Facility Operating License License No. DPR-34 0F THE PUBLIC SERVICE COMPANY OF COLORADO FOR THE FORT ST. VRAIN NUCLEAR GENERATING STATION This application for Amendment to Appendix A of Facility Operating License, License No. DPR-34, is submitted for NRC review and approval.

Respectfully submitted, PUBLIC SERVICE COMPANY OF COLORADO By R. F. Walker Chainnan, President and CEO KELLY, STANSFIELD & 0'DONNELL Bryant O'Donnell Robert E. Thompson Public Service Company Building Denver, Colorado 80202 Attorneys for Applicant

~

8512110000 851206 PDR ADOCK 05000267 P

PDR

s k

4

)

)

t ATTACHMENT 1 Summary of Proposed Changes 4

i

\\

f L

w

_y..

SUMMARY

OF PROPOSED CHANGES Section Description of Change LC0 4.3.10

1) Page 4.3 Deleted references to hydraulic and mechanical snubbers, and to Table 4.3.10-2.
2) Page 4.3 Deleted references to Table 4.3.10-2.
3) Pages 4.3-9 thru 4.3 Changed Table 4.3.10-1 heading from " Class I Hydraulic Snubbers" to " Class I Shock Suppressors".
4) Page 4.3 Changed Table 4.3.10-2 to be a continuation of Table 4.3.10-1.

SR 5.3.8

1) Page 5.3-9

- Substituted the words shock suppressors, for the word hydraulic, and deleted reference to Amendment 39.

2) Page 5.3. Deleted the reference to Table 4.3.10-2.
3) Page 5.3. Deleted a footnote referencing implementation of sample plans approved by Amendment 39.
4) Page 5.3 Deleted references to Table 4.3.10-2.
5) Page 5.3 Updated the basis to be consistent with the SR.

+

Em