April 15, 1997

Mr. Charles H. Cruse

Vice President - Nuclear Energy

Baltimore Gas and Electric Company

Calvert Cliffs Nuclear Power Plant

1650 Calvert Cliffs Parkway

Lusby, MD 20657-4702

SUBJECT:

NRC REGION I INTEGRATED INSPECTION REPORT NOS. 50-317/97-01

AND 50-318/97 01

Dear Mr. Cruse:

A safety inspection was conducted by N'lC inspectors at the Calvert Cliffs Nuclear Power

Plant from January 19,1997 to March 1,1997. The enclosed report presents the results

of that inspection. At the conclusion of the inspection, these findings were discussed with

Mr. Katz and other members of your staff.

Overall, the NRC concluded that your facility was operated in a safe manner. Durir.g the

period, a reactor downpower was conducted to investigate and isolate a small valve

packing leak on Unit 1. Also, a fire occurred in a circulating water pump exciter which

required immediate response by both operations and fire brigade personnel. Both activities

were accomplished in an well coordinated manner, without complication.

However, during this inspection period, there were two events that revealed weaknesses in

the conduct of some plant operations. Specifically, to support on-line maintenance on the

]

Unit 1 service water heat exchangers, plant operators briefly exited the technical

specification action statement to reset the action statement time clock. The maintenance

activity was planned and implemented such that a challenge to the action statement time

period would be necessary. Also, poor work practice by an auxiliary plant operator

resulted in a salt water system gate being safety tagged shut when the gate was required

to be open for safety train operability.

We believe that these events, combined with other recent events such as the inadequate

verification of the ventilation system aligr.: mnt during spent fuel handling and the poor

control of a venting evolution as discussed in NRC Inspection Report 50-317&318/96-10,

indicate a decline in performance. We also believe that management attention is needed to

address this adverse trend.

I

'

II!!}Ib!k!!lhi!.!i.!i

kbDO

17

PDR

1

g

0FFICIAL RECORD COPY

IE:01

i

_ _ _ _ _ .

t

Charles H. Cruse

2

'

Since the event regarding the resetting technical specification action statement time clock

demonstrated a poor regard for the technical specification requirement, we request you

respond to this letter within 30 days, describing your assessment of the event and any

corrective actions you have taken or planned.

We appreciate your cooperation.

Sincerely,

Original Signed by:

Lawrence T. Doerflein, Chief

Projects Branch 1

Division of Reactor Projects

Docket / License Nos:

50-317/DPR-53

50-318/DPR-69

Enclosure:

NRC Region Iintegrated Inspection Report Nos. 50-317/97-01

and 50-318/97-01

cc w/ encl.

i

T. Pritchett, Director, Nuclear Regulatory Matters (CCNPP)

'

R. McLean, Administrator, Nuclear Evaluations

J. Walter, Engineering Division, Public Service Commission of Maryland

K. Burger, Esquire, Maryland People's Counsel

R. Ochs, Maryland Safe Energy Coalition

State of Maryland (2)

1

1

-

.

.

Charles H. Cruse

3

Distribution w/ encl:

W. Axelson, DRA

D. Screnci, PAO

Nuclear Safety Information Center (NSIC)

PUBLIC

NRC Resident inspector

Region i Docket Room (with concurrences)

R. Correia, NRR

D. R. Taylor, NRR

L. Cunningham, NRR

D. Barss, NRR

L. Doerflein, DRP

T. Moslak, DRP

R. Junod, DRP

Distribution w/ encl: (VIA E-MAIL)

,

W. Dean, OEDO (WMD)

S. Stewart - Calvert Cliffs

S. Bajwa, NRR

A. Dromerick, NRR

G. Vissing, NRR

M. Campion, RI

)

Inspection Program Branch, NRR (IPAS)

'

DOCUMENT NAME: G:\\ BRANCH 1\\CCIR9701. FIN

Ta rrctive a copy of this document, indicate in the boa:

"C" = Copy without attachment / enclosure

"E" = Copy with attachment / enclosure

  • N" = No copy

OFFICE

Rl/DRP

Rl/DRP

g

NAME

SStewart 4 y& LDoerflein g7/J

DATE

04/, .;/97

h

04K /97

OFFICIAL RECORD COPY