RETURN TO 396-SS F#
M--EO THE PE N NSYLVA NI A STATE UNIVERSITY VICE PRESIDENT FOR RESEARCil AND DEAN OF THE GRADUATE SCHOOL 114 KERN GRADUATE BUILDING (D
UNIVERSITY PARK, PA 16802 4
C. L. Hosler November 8,1985 Telerhae:
k yh 6 814-865-2516 Vice President and Dean 2-814-865-6331 N0",2 g 1985 > R Mr. Charles E. Mcdonald
('
O. S. NUCLD R W,UtATORY i, Chief, Transportation Certification Branch C'
Division of Fuel Cycle and Material Safety v.,
m Washington, D.C.
20555
. w --
Dear Mr. Mcdonald:
The Pennsylvania State University Breazeale Reactor (PSBR) is committed by our response to the NRC, "Show Cause Letter," to ship off-site, 5 partial and 2 control fuel elements possessed under NRC license No. R-2.
These elements are of the 10 plate design with the uranium enriched to 93% in U-235.
The 5 partial elements have unfueled aluminum plated in some of the positions which would hold fueled plates in a full element. The 2 control elements have only 7 plates, thus providing space in the center of the element for insertion of a control rod. These two control elements are also fitted with a boss on the top end to facilitate attaching a control rod guide tube. The maximum U-235 contained in any one of the 7 elements is 133.47 grams. The seven elements contain a total of less than 700 grams of U-235.
A quality assurance program has been prepared by the PSBR staff to ensure compliance with 10CFR71, paragraph 71.12.
A copy of that quality assurance program is contained herewith.
The PSBR proposes to use 2 Model ETR, Identification number USA /9134/B( )F packages to ship the referenced fuel. These packages are certified by NRC Certificate of Compliance number 9134. The fuel will be shipped to a DOE secure facility.
By this letter, supported by the enclosed material, The Pennsylvania State University hereby requests to be named a registered user of the above described shipping containers for the purpose outlined herein.
5 Respectfully, t
00C5De hb N
4 Charles L. Hosler Z
NGV 2 01985 > ;
Vice President for Researc CLH/ IBM /pka and Dean of the Graduate S 1 e m s w.on 8
enclosures touu i ttu
.b cc:
S.H. Levine W.F. Witzig y ',
I.B. McMaster G.J. McMurtry R.W. Granlund E.C. Augustine
- ~ ~ ~'
ka
-j j L B512090536 851100 PDR ADOCK 07109134
}