Application for Renewal of QA Program for Radioactive Matl package:0392.QA Program & Shipping Papers Which Will Accompany Packages Encl.Fee Paid
ML20137T804
Person / Time
Site: 07100392
Issue date: 01/02/1986
From: Baker K
BAKER TESTING SERVICES, INC.
To: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
Shared Package
ML20137T810 List:
References
26247, NUDOCS 8602180437
Download: ML20137T804 (2)


Text

-

y

%. RETURN < *~

a~.ucw^

fo8 u

p373 A"

BAKER TESTING SERVICES. INC.

1193R thth Bein SLmet

~os oe,i r<in. i ivi. i x A s IN A TIO<.

Ibrrbl;h, MA 02368 (617)986-40 I MI tat t.UllGY AND t All UNC AN At i as January 2, 1986 Mr. Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS United States Nuclear Regulatory Commission Washington, D.C. 20555

Dear Sirs:

In order to meet the requirements of le,J R_Part 71.51 for transportation of radioactive materials we are enclosing our Quality Assurance Program and a copy of the Shipping Papers which will accompany such packages. This program is for transportation of radioactive materials to be used by us and returned by our own vehicle.

4 Very ruly yours

,9.a bli - f l'

/

~

& emf.

/

Kenneth F. Baker

]>9cV f....... ]

j.us wP

[C,tL d....

KFB/ndb i....; a mQ. 1. ?/..@t <

Enc.

.r...

GL ~.a..

u Of RECENED 6:

JAN 71986 > 7!

o 3

U 0, S. NUCt F4? RECUtATOW

'l O

CC:t's Il

/ g) 9 r ;

9 vm."m a 4

Cocang

.y us.g 6

m C

JAN L

g 1986 s.

-9

?vtr

\\o am x

V ;p rpg

' ^ '

8602180437 860102 PDR ADOCK 07100392 C

PDR 34M7 Sa w ~

e DOCKET NO._

l~ h$b

,2'.RM7l'.

conract no._-

DATE OF DOC,

/)/ / ) k b, DATE RCVD.__ M/[O 7(([o FCUF PDR FCAF LPDR k?!

ISE REF, k'MUR SAFECUARDS FCTC OTHER DESCRI. PRION:

Mu s M

mukui Nadt

/ M o u a kA n E t

_ / 6 INITIAI, h/b(,

/

/

w a dW o//om/b%

0CFR71 OA PROGRAM FOR BAKER TESTING SERVICES INC.

D 4s W v

ab2V7 ni

.monoen anons as.romnus. wec.

601 EEassG8s0 Rv0. SELLadAmm. snJ c0031

. _ _ _...... _ ~.......

DELIVERY RECEIPT DELIVERY RECElPT rec,

BAKER TESTING SERVICES INC.

G

[c 1193R North Main Street Randolph, MA 02388 s

(417) 908-4030 VIA Radioactive Materiao.l Special Form n.p.s..

a.=

vou ou.

N TO i

l l

l l

Curies Model 6

QUANTITY MO.

DESCRIPTION Iridium 192 Pro.iector l

i Radioactive Yellow II Labels l

Transport Index USA /9033/B Type B i

This is to certify that the above named materials l

l are properly classifj ed, described, packaged, marked, I

l l

l labeled ard are in pr oper condition for transportation according to the applicable regulations of the Department of Transpc rtation.

1 l

l SEDPACEASES WE DGef?

I*

meceivso ies eooo onoss e, p

p I

BAKER TESTING SERVICES, INC.

1193R ftrth Mdn Stet wwmum unm^m-h@, PA 02368 (617)986 40 I utin; uac v nw, a., u n an4< 4 m 10CF97' OA PROGRAM FOR BAKE 9 TESTING SE9 VICES INC.

1.

Organization The final responsibility for the Quality Assurance Program for Part 717equirements rests with Baker Testing Services Inc.

Design and fabrication of radioactive material shipping packages shall not be conducted under this Quality Assurance Program.

T he Quality Assurance Program is implemented using the following organization (see Appendix 1).

The Radiation Safety Officer is responsibile for overall administration of the program, training and certification, document control, and auditing.

The Radiographers are responsible for handling, storing, shipping, inspection test, operating status and record keeping.

2.

Quality Assurance Program The management of Baker Testing Services Inc. establishes and implements this Quality Assurance Program.

Training for all QA functions, prior to engagement in these functions, is required according to written procedures.

QA Program revisions will be nade according to written procedures with management approval.

The QA Program will ensure that all i

defined QC procedures, engineering procedures and specific provisions of the package design approval are satisfied.

The QA Program will emphasize control of the characteristics of the package which are critical to safety.

The Radiation Safety Officer shall assure that all radioactive material shipping packages are designed and manufactured under a Quality Assurance Program approved by the Nuclear Regulatory Commission for all packages designed or fabricated after 1 January 1979 This requirement can be satisfied by receiving a certification to this effect from the manufacturer.

o

3 Document Cont-ol All documents related to a specific chipping package will be cont"clied througa the use of written p*ocedures.

All document chant;es will be pe" formed according to written procedureu approved by nanagenent.

The Radiation Safety Officer shall insure that all QA functions are conducted in acco-dance with the latest applicable changes to these documents.

4 Handling Storage and Shipping Written safety procedures concerning the handling, storage and shipping of packages for certain special form radioactive mate"ial will be followed.

Shipments will not be made unless all tests, certifications, acceptances, and final inspections have been completed.

Work instructions will be provided for handling, storage and shipping operations.

Radiography personnel shall perform the critical handling, storage and shipping operations.

5 Inspection Test and operating Status Inspection, test and operating status of packages for certain special form radioactive material will be indicated and con-trolled by written procedures.

Status will be indicated by tag, label, marking or log entry.

Status of nonconforming parts or packages will be positively maintained by written procedures.

Radiography personnel chall perform the regulatory required inspections and tests in accordance with written procedures.

The Radiation Safety Officer shall ensure that these functions are performed.

1 6.

Quality Asaurance Records Records of package approvals (inclucing references and drawings), irspections, tests, operating logs, audit results, personnel tr aining and qualifications and records of shipr.ents will be maintained.

Descriptions of equipment and written procedures will also be maintained.

These records will be maintained in accordance with written procedures.

The records will be identifiable and retrievable.

A list of these records, with their storage locations, will be maintained by the Radiation Safety Officer.

7 Auditu Established schedules of audits of the Quality Assurance Program will be performed using written checklists.

Results of audits will be maintained and reported to managt.nent.

Audit reports will be evaluated and deficient areas corrected.

The audits will be dependent on the safety significance of the activity being audited, but each activity will be audited at least once per year.

Audit reports will be maintained as part of tne quality assurance records.

Members of the audit team shall have no responsibility in the activity being audited.

O summm mmmm i mi e i

i

APPENDIX 1 l

r t

. ' ;l U _ :a u: - Recponcible for all day

  • i day 3.L.E AdminLctrator of all exam-inat unc

,n'.h reJard to radiation cafety of competence for radiographer Radiation Sa'.ty Officer f an.a levele d ace'.ctant radiographerc. Responcible I

far adminict.'itlon of calibrations and

,,enne t n, _

Ba,r.e r l

n u.imenance ur all radiation monitoring a

equipe.en t, ran.r.a ray projectora, and all e qu ip a.e nt pertaining to and used for non-doctructive uxamination with regard to uealed courcoc.

Acciatant to Radiation Safety Officer in 7

Acciatan' i

all matterc portaining to radiation safety, I

calibration and maintenance of radiation Radiation

,,al. ty Officer monitoring equipment, gamma ray projectors e

e Donald Palmer and all equipn.ent pertaining to and used for nondectructive examination with regard

_I.

to acaled courcec.

l Snall report directly to Radiation Safety Officer and/or Acciutant Radiation Safety Officer.

Shall be recconcible for imple-Radiographer m.entation of company NRC Rulec and Regula-

^

tion; and policyc with regard to gamma ray projectors uced for nondectructive examina-tien.

1 The acciatan t radiographer chall report y

directly to the radiographer.

He chall Acuictant l

act in an acciatant capac:.ty only.

He chall bo under the d.reet cupervicion of l

Radiographer he radiographer in all r,a t terc per taining i

to radiation monitoring equipmen;, gamma ray projectors, and any and all equipment with regard to sealed courceu.

m.=-