_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ -
i GPU Nuclear g
gf 100 Interpace Parkway h
Parsippany New Jersey 07054
(
201 263-6500 TELEX 13&482 Writer's Direct Dial Number:
201-263-6797
)
February 12, 1986
$211-86-2222 l
Mr. James M. Taylor, Director i
Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C. 20555
Dear Mr. Taylor:
~
l l
In the Matter of GPU Nuclear Corporation Three Mile Island Nuclear Station. Unit No. 1 Docket No. 50-289, EA 8b-12 i
Response to Notice of Violation This is in reference to your letter of January 29, 198b, which forwarded a Notice of Violation arising from investigations of leak rate testing at TMI-l in 1978 and 1979.
That letter stated that, given the circumstances there identified, the 'NRC had concluded that no civil penalty should be proposed and that no response to the Notice was required.
i I have previously provided to you, by letter of July 20, 1984, the report of an investigation I had made of this matter.
I have no I
additional information to provide.
However, there is one error of fact in your letter.
Specifically, the statement on page two, that
" Criminal action has already been taken against GPU Nuclear for f alsifying leak rate tests at TMI-2" is not correct. The indictment and pleadings on the TMI-2 leak rate testing involved Metropolitan Edison Company, not GPU Nuclear.
Sincerely, 0'
P.R. Clark
/mak cc: F.J. Smith, President Metropolitan Edison 8602180296 860212 PDR ALOCK 0S000289 G
PDR GPU Nuclear is a part of the General Public Utilities System
[b Ol to