Dm6 Colt Industries F;irbanka Morse Engine Division 701 Lawton Avenue Beloit. Wisconsin 535115492 Telephone: 608/364-4411 Telecopier: 608/364-0382 November 26, 1985 Office of Inspection & Enforcement U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyt4, Ill. 60137 Attention:

Mr. James G. Keppler, Director, Region III Subj ect:

Colt Industries-Fairbanks Morse Engine Division Model 38TD8-1/8 Emergency Generators Connecting Rod Nuts (Bolts)

Part 21 Report Gentlemen:

During Colts factory assembly of connecting rod and rod bearing caps on a Model 38TD8-1/8 engine it was observed that the fit up of the nut to the mating surface of the connecting rod cap was not parallel. Further inspection led to the determination on November 25, 1985 that some nuts in stock have faces that are not perpendicular to the thread pitch line within the specified tolerance. This can result in a bending load being imposed on the bolt, inducing stresses beyond the design limit.

The suspect nuts are from vendor shipments received from April 9, 1984 thru the present. Nuts produced before this date were manufactured by Colt within the specified tolerance.

Utilities that could have defective parts are:

1)

Baltimore Gas & Electric Co.; Calvert Cliffs, On Site Spare Engine only.

2)

Virginia Electric & Power Co.; North Anna, On Site Spares.

3)

Philadelphia Electric Co.; Limerick Station, On Site Spares.

4)

Detroit Edison Co.; Fermi #2, On Site Spares.

To our knowledge, no operating engine, has potentially defective nuts installed, ytU Zboo 8512060241 851126 PDR ADOCK 05000317 S

PDR A deseon of the Colt industnes operstm Corp b

1l0 j

w-Offics of Insp:ction & Enforcement

,o U.S. Nuclear R:gulatory Commission November 26, 1985 Our course of action on this potential defect is to:

A)

Replace all nuts and bolts in the assembled Calvert Cliffs On Site Spare Engine.

B)

Eetermine which nuts (bolts) shipped as on site spares have been assembled (Torqued Up) and replace both nuts and bolts.

C)

Determine which nuts have not been assembled (Torqued Up) and replace these nuts.

A copy of this report is being forwarded te the Utilities involved.

We will keep you informed of our progress in this matter.

Very truly yours, e

o anager, Utili M es JMM/jl ec:

U.S. Nuclear Regulatory Commission c/o Document Management Branch Washington, D.C.

20555 Baltimore Gas & Electric Co.

Calvert Cliffs Nuclear Power Plant Routes 2 and 4, Lusby, Md. 20657 Attention:

L.B. Russell, Plant Superintendent Virginia Electric & Power Co.

North Anna Nuclear Station Mineral, Virginia 23117 Attention:

E.W. Harrell, Station Manager Detroit Edison Co.

Fermi Unit #2 6400 North Dixie Hwy.

Newport, Michigan 48166 Attention:

R.S. Lenart, Plant Surt.

Philadelphia Electric Co.

2301 Market St.

Philadelphia, Pa.

19101 Attention:

Mr. V.S. Boyer Senior V.P., Nuclear Power