Georgia institute of Technology

['

Neely Nuclear Research Center Atlanta, Georgia 30332 (404) 894-3600 GronG1ATECH 18451945 orscwn touommowtour November 15, 1985 Director Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Sir:

In accordance with the recent U.S.N.R.C. order to the Georgia Institute of Technology to move to a secure facility all unirradiated high enriched uranium fuel presently on-site, except for that needed to replace one failed element for each different type element in the core, and in accordance with 10CFR 71.12 subpart C, I hereby apply on behalf of the Georgia Institute of Technology to use NRC approved package, identifi-cation number USA /9134/B()F to ship the unirradiated fuel to Oak Ridge National Laboratory.

A copy of the certificate is enclosed.

Due to the delay in transmittance of the NRC order (November 14, 1985) your assistance in expediting this matter will be appreciated.

Sincerely,

,/,

l\\

,% ~~

R.A. Karam Director RAK:jlr 851205o066 Oj[h2j60 0

ADOCK g PDR PDR P

2 An Equal Education and Errpioyment Opportunity institution A Unit of the University System of Georgia

rars22 n:I.usra2As*srswsrsszvarammnfraur.msw:=.mzrexr:2.msmwn C FCRM 61s U.S. NUCLEAR REGULATORY COMMISSION a3, CERTIFICATE OF COMPLIANCE

, o csa r*

FOR RADIOACTIVE MATERIALS PACKAGES

- t a Cf,atipeC Us %VSER D A& tl3;CN P.w'A3ER c P ACm AGE iCENTi8.CAfiCN NLUDE A 3 8 AGE NLVSER e T0f AL bVSE4 F A A' 9134 4

USA /9134/B( )F 1

2

PotavsLE a
  • Ta.s : ' cate is.ss.e 3 to ce*Pf, *Jt tme pa;maging an 3 conteats cescritedin item 5 ce cw. meets me apphcare sa'e'y stancarcs set'Ocn n T tie 'O Coce of Fe: ras as gw'a! ces Part 7 r := aging of Aacicact ve Vateriais for Transacrt and Transportation of Rad cacNo Va'eriaf Un er Carta.n Conc <t cas e

a o Tnes : %ca e cces not rei.e., tne ::asignce from c:mor.ance

.tn any recuirement of ene reyations of the U S Ceca'tment of Tra's:criation or atae, a:: c :; e re;etatarf ageac es.a:..in; tre go.ernment cf any ca ntry threugn or into wn cn tre cackage..si ce t anspar co 3 ras CE8*'8iCA'E is SSwED CN NE 345 5 CF A SAFETv ANA$v5'S AEpCRT OF THE PACN AGE CES;GN CA APPLIC ATION a 88E2a AE3 8' ma+e s'a Aes ess e flTLE ANO ' CENT.FICAr CN OF AEFCAf CR APPtsCAf'CN Exxon Nuclear Idaho Company EG&G Idaho, Inc., Report No. PR-T-79-012, P.O. Box 2800 Rev.1, ETR Fuel Element Shiopino Container, l Idaho Falls, ID 83401 December 2,1982 (Addendum to PR-T-79-Oll (TR-4661))

71-9134 c eCC.ET ~uvoca b CCP.CF ONS l This :.anf.cate s coracit:enal wcom *w.f.l.r g tr*e requ.rements cf 10 CFR Part 71. as acclican'e and the cor'd.tions sceof.ec ceiow i

(a)

Packaging (1) Model ido.:

Elk (2)

Description The inner container is a right parallelepiped 56-3/4 inches x 16-1/2 inches x 10-13/16 inches, constructed of 3/4-inch thick plywood, covered with 16-gauge steel.

The top and bottom are lined with 1/4 inch of high density polyethylene with 0.020-inch thick cadmium plate.

The spacer separating the two layers of three fuel assemblies each consists of 1-inch high density polyethylene,1-inch of latex foam rubber, and 0.040-inch cadmium plate.

Positive closure is provided by a continuous hinge and two wire sealed hinge pins provide access.

The inner container is enclosed within an overpack, 71 inches x 21-1/4 inches a 15-3/8 inches, constructed of 1-inch thick plywood, framed by steel angle members and covered with 18-gauge steel.

Aluminum impact limiters (3-1/2 inches) are fixed to the ends of the overpack.

Positive closure of the overpack is provided by four hinge pins which are secured in place using 1/16-inch diameter cotter pins.

The package weight is approximately 690 pounds.

(3)

Drawing The packaging is fabricated in accordance with Idaho Nuclear Corporation ETR Drawing No. E-1012, Rev. E (532-0642-47-400-021712).

. JV Rbl m_______

~.,

-m.u C t.NL-

ontanusdp y

i g

Page 2 - Certificate No. 9134 - Revision No. 4 - Docket No. 71-9134 h

E i

1 5.

(b) Contents 4

1 (1) Type and Fonn of Material y

Solid unirradiated aluminum plate type fuel element or control rod 3

follower piece provided it contains no more than 520 grams (maximum of f

300 grams / foot) of U-235 per element or follower piece.

l (2) Maximum quanity of material per package

[

Six (6) fuel elements or control rod follower pieces (one in each compa rtment).

Total U-235 content not to exceed 3,120 grams per package.

l (c) Fissile Class I

6.

The contents must be maintained within the respective element compartments and the active fuel lengths nust be completely within the regions of the cadmium covered spacers. Wood spacers may be used to accomplish this.

7.

Chemical composition of the contents must not have a hydrogen atom density, when averaged over the volume of the contents, greater than that of water at one gram per cubic centimeter.

8.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 971.12.

9.

Expiration date:

October 31, 1989.,

REFERENCES EG&G Idaho, Inc., Report No. PR-T-79-012, Rev.1, Decenber 2,1982.

Aero. jet Nuclear Company, Report No. TR-466, June 30,1975 (Docket No. 71-9099); or, EG&G Idaho, Inc., Report No. PR-T-79-011 (TR-466 re-issued).

FOR THE U.S. NUCLEAR REGULATORY COMMISSION

    • ^ L p Charles E. MacDonald, Chief Transportation Certification Branch' Division of Fuel Cycle anc' Material Safety, NMSS OCT 0 91984 Date:

l 1EEEY

[g%

WMX Ws T T WYMM TYY7EM*_V MEETg k

_kE117 Y. [

R. A. Karam CORRESPONDENCE CONTROL TICKET

\\

SECY NUPEER:

85-1005 LOGGING DATE 11/22/85 0FFICE OF THE SECRETARY Davis, NMss for approp. action cys: Denton ACTION 0FFICE:

ED0 Taylor Grace AUTHOR:

R. A. Karam GCunningham/ Burns LPDR AFFILIATION:

Georgia Institute of Technology PAnderson LETTER DATE:

11/20/85 FILE CODE ADDRESSEE:

Hoyle Reg extension period in compliance to 9/27/85 show cause order SU8 JECT:

re unirradiated fuel in non res reactors ACTION:

Appropriate DISTRIBUTION:

Don C&rlson SPECIAL HANDLING:

None SIGNATURE DATE:

FOR THE COPNISSION cha73 Date.....U.T.9. N' T g' P ee'd off. EDO Time.....6%Eh.....,

I