Requests Meeting to Discuss Concerns Re Accelerated Schedule of Facility Power Ascension Program.Proposed Program Represents Radical & Safety Significant Departure from NRC Practices & Util FSAR Commitments
ML20137N262
Person / Time
Site: Hope Creek 
Issue date: 11/04/1985
From: Shapiro R
NEW JERSEY, STATE OF
To: Harold Denton, Fraley H
Advisory Committee on Reactor Safeguards, Office of Nuclear Reactor Regulation
References
NUDOCS 8512040092
Download: ML20137N262 (2)


Text

%

a j

43, Q.t etate of Netu !Ierscu DEPARTMENT OF THE PUBLIC ADVOCATE DIVISION OF PUBLIC INTEREST ADVOCACY Alfred A. Slocum TRENTON, NEW J RSEY 04625 November 4,1985 oYnEcton N

COMuiSSIONER TEL 609-292-1693 Mr. Harold Denton Director Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, MD 20014 e

Mr. Harold Fraley Executive Director Advisory Committee on Reactor Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Re: Hope Creek Generating Station Power Ascension Program

Dear Messers. Denton and Fralcy:

The New Jersey Department of the Public Advocate is an independent cabinet-level agency of New Jersey state government which is authorized by statute to represent the public interest of New Jersey citizens.

Our review of the enclosed proposal by Public Service Electric and Gas Com-pany of New Jersey (PSE&G) to accelerate the Hope Creek power ascension schedule has compelled us to write you, since the proposed program appears to represent a radical and safety significant departure from current and past NRC practices and from PSE&G's operating license commitments in its FSAR.

The Department of the Public Advocate of the State of New Jersey is extremely concerned that this truncated testing program will be implemented without sufficient review and evaluation and will result in a substantial risk to the health and safety of New Jersey residents.

While the precise details of the PSE&G power ascension testing pro-posal have apparently not yet been formulated, PSE&G will seemingly rely on risk based assertions, deferral of plant modifications, and other factors such as QA/QC to request relief or exemptions from current Technical Specification and other normal licensing requirements.

Moreover, it appears that the NRC will be requested to review PSE&G's specific proposals regarding its power ascension testing program on a very e,,s,,1204oon 8s,g,k,4

@\\

AoOcs 0

i.,,, r.v...i o,,..,,......, e..,ci.....,

,o A

J

L

.y 4

Mr. Harold Denton Mr. Harold Fraley November 4,1985 G

expedited basis.

Finally, PSE&G appears to be proposing to expand its authority under Section 50.59 of 10 C.F.R. Part. 50 to unilaterally make changes, while reducing the NRC's authority under Sections 50.95 and 50.12(a) to regulate licensing amendments and regulatory exemptions.

PSE&G's power ascension testing program thus raises serious concerns relating to the public interest of all New Jersey citizens.

Specifically, the Public Advocate is very concerned that the power ascension program con-templated by PSEhG represents both a significant new practice by an applicant and a substantial departure from staff licensing procedures.

Since this accelerated process could compromise the health and safety of New Jersey residents, the Department of the Public Advocate of the State of New Jersey requests that you take whatever actions are necessary to ensure that such changes in NRC practices and standards are developed in a reasoned manner with appropriate time for review and comment by all interested parties.

We also would like to meet in the near future with appropriate NRC officials to discuss our concerns in more detail.

Please advise us of whom we should contact for such a meeting.

Thank you for your consideration and assistance.

Sincerely yours, l j*g' g, *in

/ g R1 HARD E.+SHAPIRO Director RES:id Enclosure cc: Walter R. Butler Stewart D. Ebneter Harry B. Kister A.R. Blough S.K. Chaudhary Lee Scott Dewey, Esq.

. David Wagner Peter Hess, Esq.

Richard F. Engel, Esq.

Ken Koschek R. Edwin Selover, Esq.

_