ML20137L665
| ML20137L665 | |
| Person / Time | |
|---|---|
| Site: | Davis Besse |
| Issue date: | 01/20/1986 |
| From: | Williams J TOLEDO EDISON CO. |
| To: | Harold Denton Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML20137L669 | List: |
| References | |
| REF-GTECI-A-49, REF-GTECI-RV, TASK-A-49, TASK-OR 1236, TAC-59950, NUDOCS 8601280051 | |
| Download: ML20137L665 (1) | |
Text
}-
J TOLEDO I!E3l!I(IF$
Docket No. 50-346 JOE VVLUAMS, Ja License No. NPF-3 Seur We Proww=t -Nudra (4191243 2300 Serial No. 1236 (4191249 3223 January 20, 1986 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, D.C.
20555
Dear Mr. Denton:
In accordance with the requirements of-10 CFR 50.61, Fracture Toughness Requirements for Protection Against Pressurized Thermal Shock Events, Toledo Edison's assessment of the Davis-Besse Unit No. 1 (DB-1) reactor vessel has been submitted in the Babcock & Wilcox (B&W) report, BAW-1895, l
" Pressurized Thermal Shock Evaluations in Accordance with 10 CFR 50.61 for Babcock & Wilcox Owners Group Reactor Pressure Vessels". This report was transmitted to the NRC (Mr. H. N. Berkow) from the B&W Owners Group by letter dated January 20, 1986.
Toledo Edison has determined, through the prescribed methods of 10 CFR 50.61, that the DB-1 reactor vessel will not exceed the established RTPTS screening criteria prior to the expiration date of the DB-1 Operating License. Additionally, the RT values calculated for DB-1 as of January 23, 1986 areasprovidedonAt$I!hment I to this letter. The values listed on Attachment I are supplemental information to Table 4-8 of the B&W Owners Group report, BAW-1895.
Toledo Edison considers the immediate. action required by 10 CFR 50.61 to be complete. The NRC will-be notified whenever changes in core loadings, surveillance measures or other information indicate a significant change in the projected RTPTS ""
"*8*
Very truly yours, AD = D. CRUTCHF1 ELD (Ltr only)
Z e
I
, Rss S
' 6' 8'cS* (rda"8 W:RJG:DJS:lah
'" i" 85'*)
attachment f
cc: DB-1 NRC Resident' Inspector 00 t
i 8601280051 860120 DR ADOCK 05000346 p
.THE TOLEDO EDISON COMP 4'NY EDISON PLAZA 300 MADISON AVENUE TOLEDO. OHIO 43652
.