Text

_

m Public Service Electric and Gas Company Cctbin A. McNeill, Jr.

Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge. NJ 08038 609 339-4800 Vice Presiaent-Nuclear January 20, 1986 Director of Nuclear Reactor Regulation United States Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, Maryland 20814 Attention:

Ms. Elinor Adensam, Director Project Directorate 3 Division of BWR Licensing

Dear Ms. Adensam:

PRESERVICE INSPECTION PROGRAM RELIEF REQUESTS HOPE CREEK GENERATING STATION DOCKET NO. 50-354 Enclosed for your review are the Public Service Electric and Gas Company (PSE&G) Relief Requests for the Hope Creek Generating Station (HCGS) Preservice Inspection (PSI) Program.

This transmittal supersedes the letter from Mr.

R.L. Mittl (PSE&G) to Mr.

W.

Butler (Nuclear Regulatory Commission

- NRC) dated November 18, 1985 and reflects discussions i

between the NRC staff and PSE&G on December 9, 1985 and January 10, 1986.

This transmittal provides all PSI Relief Requests with the appropriate technical justifications from any impractical ASME Code Requirements.

This resolves Safety Evaluation Report (SER) Open Item 3, currently identified as " confirmatory" in SER Supple-ment 4.

Should you have any questions on the subject filing, do not hesitate to contact us.

Sincerely, I

8601240215 860120 PDR ADOCK OS000354-V t

s\\

E PM l

i

,, - -. - -. ~, -

Director of Nuclear 2

1-20-86 Reactor Regulation Attachment C

D.H. Wagner USNRC Licensing Project Manager R.W.

Borchardt USNRC Senior Resident Inspector