Georgij Power Company Rout) 2. Box 299A W:ynesboro, Georgia 30830 Telephone 404 554 9961 404 724-8114 Soutnern Company Services, Inc.

Post Office Box 2625 m

Birmingham, Alabama 35202 Telephone 205 8704011 Vogtle Proj.ect November 26, 1985 Director of Nuclear Reactor Regulacica File: X7BC35 i

Attention:

Mr. B. J. Youngblood Log:

GN-750

)

Licensing Branch #4 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C.

20555 REF: LETTER FROM E. G. ADENSAM (NRC) TO D. O. FOSTER (GPC) DATED 9/6/85 NRC DOCKET NUMBERS 50-424 AND 50-425 CONSTRUCTION PERMIT NUMBERS CPPR-108 AND CPPR-109 V0GTLE ELECTRIC GENERATING PLANT - UNITS 1 AND 2 SER OPEN ITEM 4 - T0XIC GAS EVALUATION

Dear Mr. Denton:

In the referenc' d letter you requested that Georgia Power Company (GPC) e provide an analysis to estimate the chlorine concentration at the VEGP control building air intake, due to the rupture of a one-ton chlorine cylinder, using three atmospheric dispersion models and related equations identified by your staff. The attached evaluation is provided in response to that request.

Based on our evaluation of the three models, we have concluded that the Regulatory Guide 1.95 model is appropriate for use in evaluating the VEGP control room habitability. Consequently, chlorine concentrations predicted by this model for 5 percentile dispersion conditions will be used in a subsequent evaluation of chlorine concentrations that could occur inside the VEGP ontrol room. The results of this control room habitability evaluation will be provided by February 1986.

If you have any questions, please contact us.

Sincerely, 8512030200 851126 PDR ADOCK 05000424 E

PDR J. A. Bailey Project Licensing Manager JAB /sm xc: List attached.

t i

Director of nuclear Reactor Regulation File: X7BC35 November 26, 1985 Log:

GN-750 Page 2 xc:

R. E. Conway M. A. Miller B. A. Jones G. Dockhold, Jr.

B.. W. Churchill, Esquire L. T. Gucwa J. E. Joiner, Esquire R. A. Thomas W. C.:Ramsey L. Fowler T. Johnson D. C. Teper Vogtle Project File 0246V