Application for Amend to License NPF-4,changing Tech Specs to Authorize Operation at 2,775 Mwt W/Steam Generator Tube Plugging of Up to 7%.Fee Paid
ML20137K383
Person / Time
Site: North Anna 
Issue date: 01/17/1986
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, Rubenstein L
Office of Nuclear Reactor Regulation
Shared Package
ML20137K386 List:
References
85-890, NUDOCS 8601240048
Download: ML20137K383 (3)


Text

V VINGIN1A ELucrxIC AND POWER COMI*ANY HICHMOND, VIHOINIA 2 OuG1 W.L.SrnWART Vaca P=asionur wo ci.=* = o r = =irio==

January 17, 1986 Mr. Harold R. Denton, Director Serial No.85-890 Office of Nuclear Reactor Regulation E&C/NPW/acm Attn: Mr. Lester S. Rubenstein, Director Docket No. 50-338 PWR Project Directorate #2 License No. NPF-4 Division of PWR Licensing-A U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT NO. 1 PROPOSED TECHNICAL SPECIFICATIONS CHANGE R

Pursuant to 10CFR50.90, tne Virginia Electric and Power Company requests an amendment, in the form of changes to the Technical Specifications, to Operating License No. NPF-4 for North Anna Power Station Unit No.1.

Current steam generator tube plugging levels in both North Anna units remain below the value of 5 percent assumed in the currently docketed LOCA-ECCS analysis (W.

L.

Stewart to H.

R.

Denton, Serial No. 726, December 30, 1982). Since it is possible that future steam generator tube plugging may exceed the current analysis limit, a LOCA-ECCS re-analysis is being submitted to support operation of North Anna Unit 1 at 2775 MWt with steam generator tube plugging levels of up to 7 percent. The re-analysis was performed for uprated power conditions. Operation at the current licensed power level will be bounded by the results of the uprated analysis when operating at an FQ limit of 2.15. provides an evaluation justifying the use of the LOCA-ECCS analysis performed at uprated power conditions to support operation at the currently licensed reactor power level of 2775 MWt. The results of the re-analysis are provided in Attachment 2 while the proposed changes to the Technical Specifications are provided in Attachment 3.

In addition, as required by Specification 6.9.1.4, a revised Core Surveillance Report for North Anna 1 Cycle 6 operation in a manner consistent with the lower FQ limit is provided in Attachment 4.

This request has been reviewed by the Station Nuclear Safety and Operating Committee and the Safety Evaluation and Control staff.

It has been determined that this request does not involve any unreviewed safety questions as defined in 10CFR50.59 or a significant hazards consideration as defined in 10CFR50.92.

eAel eOAe e m a,.

SI

@g 1

PDR ADOCK O PDR P

SG

T Vanotw A ELecraIC AND Powna Couraxy to Mr. Harold R. Denton We have evaluated this request in accordance with the criteria in 10CFR170.12.

A voucher check in the amount of $150 is enclosed as an application fee.

Very truly yours, W. L. Stewart Attachments 1.

Safety Evaluation for 7% Steam Generator Plugging Level in North Anna Unit No. 1 2.

LOCA-ECCS Safety Evaluation for North Anna Unit No. 1 3.

Proposed Technical Specification Changes 4.

Revised Core Surveillance Report for North Anna 1 Cycle 6 cc:

Dr. J. Nelson Grace Regional Administrator NRC Region II Mr. Morris W. Branch NRC Resident Inspector North Anna Power Station Mr. Charles Price Department of Health 109 Governor Street Richmond, Virginia 23219 Mr. Leon B. Engle NRC North Anna Project Manager PWR Project Directorate #2 Division of PWR Licensing-A L

. - =

J l

4

)

i i

COMMONWEALTH OF VIRGINIA )

)

CITY OF RICHMOND

)

The foregoing document was acknowledged before me, in and for the City and Commonwealth aforesaid, today by W.

L.

Stewart who is Vice President Nuclear Operations, of Virginia Electric and Power Company.

He. i's duly authorized to execute and file the foregoir.g document ' in behalf of that Company, 'and the statements in the document are true to the best of his l

knowledge and belief.

Acknowledged before me this D

day o D L oc.~.

19 b My Commission expires:

ke-

  • -v a u,

\\o 19 D i

\\

4 I

\\

lko %_

Oh_

i NotapyPublic i

i I

i I

(SEAL) l i

s/001 1

u-

.m

,_,__.,,,,.,_y.

.y

-g.7_.,

e,.-..

_