ML20137G897

From kanterella
Jump to navigation Jump to search
PNO-IIT-86-001B:on 851228,Incident Investigation Team Began Investigation Into 851226 Loss of Power to Integrated Control Sys Reactor Trip on High Pressure & Rapid Cooldown Following Reactor Trip
ML20137G897
Person / Time
Site: Rancho Seco
Issue date: 01/09/1986
From: Hebdon F
NRC - INCIDENT INVESTIGATION TEAM
To:
References
PNO-IIT-86-001B, PNO-IIT-86-1B, NUDOCS 8601210323
Download: ML20137G897 (1)


Text

_ _.

PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-IIT-86-01B Date:'1/9/86 Thia preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public 12tsrest significance.

FACILITY: Sacramento Municipal Utility District Emergency Classification Rancho Seco Notification of Unusual Event Docket No. 50-312 Alert Site Area Emergency General Emergency

_X_Not Applicable

SUBJECT:

STATUS REPORT FROM THE NRC INCIDENT INVESTIGATION TEAM l

On December 28, 1985, an Incident Investigation Team (IIT) began an inv;stigation of an incident that occurred at Rancho Seco on 12/26/85. The cv:nt includedsa loss of power to the Integrated Control System (ICS), a rmetor trip on high pressure, and a rapid cooldown following the reactor trip. The team completed'its on-site investigation on January 8, 1986,

.cnd is returning to Bethesda,-Md., to continue'its investigation.

Th7 team interviewed all operators directly involved with the event, developed a c;quence of events, developed an equipment quarantine list of failed cquipment, reviewed the trouble-shooting plans for components on the quarantine lict, and conducted extensive technical. discussions of issues directly related to the event.,All interviews and technical discussions have been transcribed in crder to provide a complete record,of'the investigation.

Tha trouble-shooting will be conducted by the' licensee and monitored by personnel from Region V.

The results of the trouble-shooting will be reviewed by the IIT baftre any repair work on the components is initiated. A report of the rn ults of the investigation will be prepared by the team and issued in cid-February 1986.

Thio information is current as of January 8, 1986.

CONTACT:

Frederick J. Hebdon, X24484 DISTRIBUTION

%Ib A

dar M lInf AM ll.'If M H St. \\b. dWN MNBBih6MPhillips"# riE/W Willste Air Rights Mail:

Ch irman Palladino EDO NRR IE NMSS ADM:DMB Comm. Zech PA OIA RES DOT:Trans Only Comm. Bernthal MPA AEOD Comm. Roberts ELD Comm. Asselstine Regions:

SECY INFO NSAC ACRS Licensee:

CA (Reactor Licensees)

REGION V: FORM 211 PDR Resident Inspector _

(Revised 3/14/83) 8601210323 860109 g/['-

18E PDR PNO-III-85-001 PDR g