ML20137F388

From kanterella
Jump to navigation Jump to search
Forwards Final Rept on Insp Issue 82-05, Rept on Braidwood Safety-Related Mechanical Equipment Retrofit Program, Re Installation of Certain safety-related Equipment by Phillips Getschow Co.Related Correspondence
ML20137F388
Person / Time
Site: Braidwood  Constellation icon.png
Issue date: 01/13/1986
From: Gallo J
COMMONWEALTH EDISON CO., ISHAM, LINCOLN & BEALE
To: Callihan A, Cole R, Grossman H
Atomic Safety and Licensing Board Panel
References
CON-#186-764 OL, NUDOCS 8601170504
Download: ML20137F388 (34)


Text

mo D

T\\

ISHAM,k.lNCGLN & BEALE DOUCE:

COUNSELORS AT LAW

' SZ

'86 JAN 15 A10:51 TMm FIRST pTOML MA CHICAGO. lLUNOI560602

'"u LFFICi 0F SECHt fan -

^

00CKETING & SENVlCi WA$HINGTON. D C 20036 BRANCH 202 822 =

January 13, 1986 Herbert Grossman, Esq.,

Dr. Richard F. Cole Chairman Administrative Law Judge Administrative Law Judge Atomic Safety and Licensing Atomic Safety and Licensing Board Board U.S. Nuclear Regulatory U.S. Nuclear Regulatory Commission Commission Washington, D.C.

20555 Washington, D.C.

20555 Dr. A.

Dixon Callihan Administrative Law Judge 102 Oak Lane Oak Ridge, Tennessee 37830 Re:

In the Mat ter of Commonwealth Edison Company (Braidwood Station, Units 1 and 2'L' Docket Nos. 50-456 and 50-457)

O Gentlemen:

I am enclosing Commonwealth Edison's final report on the 82-05 issue.

This report, entitled " Report on Braid-wood Safety-Related Mechanical Equipment Retrofit Program" addresses concerns raised by the NRC Staff in I&E inspection report 82-05 with respect to the installation of certain safety-related equipment by Phillips Getschow Company.

The report is relevant to several items of Interventors Rorem, et al. quality assurance contention.

Copies of the report were furnished today to Mr.

Guild and counsel for the NRC Staff.

8601170504 860113' Sincerely, PDR ADOCK05000p4

/G JG:hmw Joseph Gallo Enclosure One of the Attorneys for Commonwealth Edison Company cc:

Service List

/7

r

)

1 Commonwealth Edisin Co.

Br:-idwood StItion j

RR 1. Box 81 Braceville. IL 60407 6

Telephone 815/458-2801 January 13, 1986 Mr. James G. Keppler Regional Administrator U.S. Nuclear Regulatory Commission 199 Roosevelt Road Glen Ellyn, IL 60137

Subject:

Braidwood Generating Station, Units 1 and 2 Safety-Related Mechanical Equipment Retrofit Program - Final Report 10 CFR 50.55(e) No. 82-07 Final Report i

NRC Docket Nos. 50-456 and 50-457 1

Dear Mr. Keppler:

The purpose of this letter is to transmit the Report on Braidwood Safety-Related Mechanical Equipment Retrofit Program. That program was undertaken to resolve the concerns documented by your Staff in Reference (a) with respect to the adequacy of the installation before September, 1982 of safety-related mechanical equipment at Braidwood Station. Tne attached report documents the results of that program which is now complete. Accordingly, it is judged that a review of this report and the supporting documentation justifies closure of your inspection report on this matter (82-05-04) as well as Braidwood 55(e) Report 82-07.

One signed original and 19 copies of this letter and 20 copies of the Report are submitted for your use.

If there are any questions on the Report or the Retrofit Program, please direct them to this office.

Very truly yours, Louis O. DelGeorge Assistant Vice-President LOD /pav Attachments cc: Resident Inspector - Braidwood 12061

a

.c t

(

F.

REPORT ON BRAIDWOOD SAFETY-RELATED MECHANICAL EQUIPMENT RETROFIT PROGRAM

(

Docket Nos. 50-456 and 50-457 January 1986 11931 k

4.

'4.

REPORT ON BRAIDWOOD SAFETY-RELATED MECHANICAL EQUIPMENT RETROFIT PROGRAM TABLE OF CONTENTS PAGE I.

INTRODUCTION 1

II.

METHODOLOGY 4

III. RESULTS 6

IV. ' CONCLUSIONS 12 V.

REFERENCES 13 APPENDIXES A.

REIROFIT PROGRAM INSPECTION ATTRIBUTES 14 k'~

B.

DETAILED RESULTS OF THE RETROFIT PROGRAM 16 C.

STEAM GENERATOR BOLTING 26 11931

(

c

(

N'

,I.

INTRODUCTION

~

This report documents the results of reviews conducted by Commonwealth Edison Company-(CECO) of the installation of safety-related mechanical equipment at Braidwood Station. The equipment reviewed was installed by the Phillips Getschow Company (PGCo). The installation of mecnanical equipment, as stated in the Braidwood FSAR, was to be in accordance with the provis2cns

(

of ANSI N45.2.8-1975 " Supplementary Quality Assurance Requirementr,for s

Installation, Inspection and Testing of Mechanical Equipment and Systems for '

the Construction Phase of Nuclear Power Plants". This commitment is contained in the Braidwood FSAR, Appendix A, reference to US NRC Regulatory Guide 1.116 dated May 1977 which endorses the provisions of ANSI N45.2.8-1975.~

Although a total of 388 safety-related equipment items are included within the scope of PGCo's installation responsibility, this report will discuss only those 216 items for which installation began prior to September 2, 1982. On that date, PGCO implemented Procedure QCP-B22 governing i.

installation of safety-related mechanical equipment, which was approved by CECO. Although various controls and procedures for installation of safety-related mechanical equipment had been utilized to some ertent prior to September 2,1982, neither CECO nor the NRC was satisfied with the adequacy of the installation program because of inadequacies both in the scope and implementation of those controls and procedures.

A historical discussion of the PGCo safety-related mechanical equipment installation procedures was provided by CECO in Reference 1 (55(e) Report 82-07), which documented the deficiencies in the PGCo program pursuant to the requirements of 10 CFR 50.55(e). That chronology will not be repeated herein. In addition, the NRC Staff documented its review of the controls originally imposed by PGCo on safety-related mechanical equipment in IE Report 1

11931

l 50-456/82-05 and 50-457/82-05 (Reference 2)" at which time the deficiencies

.noted were characterized by the Staff as evidencing a breakdown in the Ceco Quality Assurance (QA) program as it relates to the installation and installation inspection of mechanical safety-related equipment.

In its response to that' inspection report (Reference 3), CECO denied that these

' deficiencies in fact constituted a' breakdown in QA as applied to the subject equipment installation. CECO had undertaken an extensive review of the PGCo equipment installation program, and work on that activity had been stopped prior to the NRC Staff inspection. That review was adjusted, as necessary, to address issues raised-by the NRC Staff. The review of the PGCo equipment installation program included both an assesment of the adequacy of procedures

.for prospective implementation and a retrofit review of all previously installed equipment within the PGCo scope of work to verify the adequacy of those installations. It is the results of the retrofit effort (hereafter

( '

referred to as the' Safety-Related Mechanical Equipment Retrofit Program, or Retrofit Program) that are documented in this report.

Although the focus of the CECO response to the NRC Staff IE Report 82-05 was on the effective resolution of the identified deficiencies limited to the PGCO equipment installation program, a broader review of the entire PGCo safety-related work scope as well as the safety-related work then being conducted by other contractors in the area of electrical, structural and HVAC was also made by CECO to assess the generic implications of PGCo deficiencies to other activity areas. The results of those reviews have previously been discussed with the NRC Staff and documented (Reference 4) and will not, therefore be further discussed in this report except to observe that although limited deficiencies in certain procedures were identified and corrected, a lack of procedural control of the type determined to exist with respect to safety-related mechanical equipment installation was not identified.

(

2 11931

F i'.

Installation of certain safety-related equipment items, specifically the steam generators, are a part of the nuclear steam supply system (NSSS).

Y Certain installation activities did not fall within the PGCo work scope defined in the mechanical equipment installation specification. The NSSS equipment was erected and installed by other contractors and appropriate installation and installation inspection procedures were in place at the time. ' However, PGCo had the responsibility of. installing the cap screws which attach the steam generators to their supports, and asserted deficiencies in cap screw installation and traceability were also set forth in Inspection Report 82-05.

Actions taken to resolve those deficiencies are discussed in Appendix C of this report.

(

0 l

l

(

l i

11931

u i

II, METHODOLOGY

. {C As has previously been documented in Reference 3, CECO implemented a verification review of all safety-related mechanical equipment installed prior

to September,.1982. That review satisfied the procedural requirements of PGCo Procedure QCP-B22 Rev. O and was completed in December, 1982.

The scope of the program incl'ded all installation activities performed on safety-related mechanical equipment prior to September 1,1982.

216 piecea of' mechanical equipment were identified as being in various stages of f.e installation from initial rough set to final set, aligned, grouted and piped as of that date. For each piece of equipment, PGCo engineering personnel reviewed applicable architect / engineer specifications and drawings and equipment vendor drawings, manuals, and instructions to determine all applicable equipment installation requirements. These requirements were documented on the Equipment Installation Record (EIR) form, QCP-B22-1.

This

~

form provided detailed ' steps necessary for the installation and inspection of a piece of equipment. Those steps which had been previously completed for th -

equipment, which were those requiring retrofit inspection, were highlighted on the form. These forms were sent to PGCo QC and CECO Site QA for the assignment of' inspection hold points..The forms were then sent to the field to provide control, instruction, and to assure appropriate documentation of E

retrofit inspections. These inspections were performed by PGCo QC personnel and, as requireds PGCo production personnel for each attribute required by the EIR. Findings of deviations from installation requirements (including inadequate documentation) and an identification of those installation attributes which were not recreatable at the time of the retrofit inspection were documented. For attributes which were partially reinspectable, such an foundation checks with the equipment set, reinspections were performed to the 4

11931

'9 extent possible. For attributes previously inspected and documented, reference to the previous documentation was provided. The attributes inspected are described in Appendix A.

The equipment installation verification program completed in December 1982 provided documented evidence of the quality of mechanical equipment

-installations completed prior to S'eptember 1982. Thereafter, installation-activities continued with respect to some of the 216 pieces of equipment and PGCo Procedure QCP-B22 was revised. The data form which listed the inspection attributes for each piece of equipment became more detailed and it was decided to reinspect, as necessary, the 216 pieces of equipment in order to conform the installation inspection documentation to the applicable revision of QCP-B22 (i.e. Rev. 5).

In addition, an inspection attribute, internal cleanliness, which had earlier been waived in the retrofit inspections based on dystem flushing, was re-established as a retrofit inspection attribute.

Further, a n. ore detailed retrofit inspection of grouting activities was initiated after December, 1982. A limited further number of discrepant installation attributes and incomplete documentation were identified and dispositioned by PGCo. This activity began on an expedited basis in July, 1985 and is now complete.

(

5 11931

'III. RESULTS The implementation of the mechanical equipment retrofit program provides the basis for demonstrating that the erection of the 216 pieces of mechanical equipment installed prior to September 2,1982 is in conformance with the requirements of ANSI N45.2.8-1975. This documented assurance of conformance with this ANSI standard is the primary result of the program. Evidence of this conformance is contained in documentation generated in accordance with PGCo procedure QCP-B22. This documentation is contained in " equipment packages" which are organized by equipment number and are currently located in the PGCo QA vault.

The program also provides for the identification and subsequent disposition, and corrective action, as appropriate, of deficiencies in the existing equipment erection status and associated documentation identified during the course of this retrofit inspection program. The documentation of 1'

these deficiencies is also contained or referenced in the previously identified equipment packages. It should be observed that some of the deficiencies identified were dispositioned on the basis of an NCR which dealt with the discrepancy programmatically, while others were identified on individual pieces of equipment. A tabulation of the individually identified deficiencies by equipment and deficiency type is provided in Appendix B.

The following provides a summary of these discrepancies.

Anchor Bolts Anchor bolts are used to secure equipment to the concrete equipment pad.

These bolts are typically embedded in the concrete structure. Anchor bolting was inspected for bolt angularity, size, thread condition, hole size, nut engagement, nut torquing, and for sliding connections, location of the bolt relative to the slotted hole.

l 6

11931

I' l

L h

Out of the 216 pieces of-equipment, only ten were identified in which

{:

anchor bolt nut thread engagement did not meet the requirement of the nut being_at least fully engaged and flush with the end.of the bolt. For four pieces, each had one of their 8, 12, 16 and 27 respective anchor bolt nuts

. ith engagement one half thread less than flush. For another four pieces, w

each had one of their 10, 12, 16 and 27 respective nuts one thread less than flush. One piece had one of ten bolt nuts two threads below flush. One piece had hold down bolts of 1 1/2 inches in diameter which were engaged between l'1/16" and 1 3/16" where 1 1/2 inches was required. All of these conditions were accepted-as-is,-except in two cases in which washers were removed to increase thread engagement.

Damaged or out-of-tolerance bolts were identified for 12 of the 216 pieces of equipment. Four of these pieces of equipment had a total of 6 of 70 L<

bolts with damaged threads. -One piece of equipment had one bolt of 18 sheared while another piece had two of 12 bolts broken. One piece had one bolt of 18 with angularity greater than three degrees. Three pieces of equipment had bolt projections which were out of tolerance. Two of these pieces had 3 3/4 inch bolts which were up to 1/2 inch short. For the. remaining piece, the projection was slightly greater than required. Two pieces of equipment utilized standard nuts on one bolt out of 8 and 12 respectively in lieu of the required heavy hex nuts. All of these discrepancies were accepted-as-is j~

except for one piece of equipment in which the standard nut was replaced with the required heavy hex nut.

Anchor alt-holes or bolt-to-hole clearances out of tolerance were i-observed for six of the 216 pieces of equipment. Two of these involved l

deviations in the clearance of the bolt-to-hole for sliding connections. In each case, one of eight bolts was out of tolerance; one by 0.02 inches, and k

l

[

7 11931 l

i j

m_

r

^*

.i

(

one by 0.075 inches. Four involved bolt holes the dimensions of which were different from those shown on the drawing. In one case, 1 out of 18 1 1/8 inch diameter holes was elongated by 1/4 inch. In the three other cases, equipment as-supplied by the vendor slightly deviated from the vendors' drawings. All were accepted-as-is except one bolt-to-hole clearance which was reworked by PCCo.

One' additional discrepancy was identified in which two bolts on crie piece aof equipment lacked washers. This discrepancy was accepted-as-is.

Cleanliness During the. course of the retrofit inspection program, internal cleanliness inspections of equipment piping connection internals could not be

_ performed for those pieces of equipment for which piping connections were completed. These cleanliness inspections were waived by CECO in September 1982 based on planned system flushing activities. In some cases, these bypassed inspection hold points were documented on NCR's and other deficiency

. documents.

In February 1984, the NRC questioned the acceptability of waiving cleanliness hold points based on flushing alone. The NRC initiated open items 50-456/84-06-05 and 50-457/84-06-05 (Reference 5) to document their concern.

The NRC later raised this open item to an item of noncompliance as documented in Inspection Reports 50-456/84-21 and 50-457/84-20 (Reference 6).

As a result of the NRC inspection in February 1984, CECO initiated NCR 614 dated April 4, 1984 to document that the waivers of internal cleanliness by CECO project Construction Department lacked appropriate engineering concurrence. Engineering review of this NCR resulted in a disposition which recommended that additional visual inspections for equipment internal k

8 11931

cleanliness be performed. These reinspections were facilitated by the use of I'

remote visual inspection devices (e.g. boroscopes), selected disassembly of pumps and piping flanges, and creating access holes in' piping. However, for twenty-one pieces of equipment, the use of flow verification in conjunction with flushing for the verification of internal cleanliness of one or more equipment connections was specifically approved by engineering. Successful flushing and system flow has confirmed internal cleanliness for seven of these twenty-one pieces of equipment. The flushing and flow verification of the remaining 14 pieces is being tracked by individual CECO deficiency documents.

The pieces of equipment for which flushing and flow verification was employed for verification of equipment cleanliness in lieu of visual inspections are documented in the disposition of NCR 614.

Grouting

' Grout is used to provide for the uniform transfer of loads f rom the equipment base to the structure. It is placed between the equipment base and the concrete pad. Prior to the equipment retrofit inspection, procedures required a " grout release" form to be generated to indicate that equipment erection activities had progressed to the stage where equipment base plate grouting could proceed. Thirty-three findings were written for equipment grouted without evidence of a grout release.

Under-the retrofit program, these pieces of equipment and all other previously grouted pieces of equipment were inspected for grouting to the extent possible.

As a result of questions raised by PGCo's grout retrofit inspections, G.K. Newberg, the contractor responsible for performing grout placement and

-inspections, performed a review of completed grouting of all equipment bases

'l 9

11931

h L. w:

L;;

for the presence of possible voids under base plates and grouting cracks.

These-inspections, performed between January and July 1983, resulted in CECO NCR 560 dated July 13, 1983. This NCR documented the presence of cracked or chipped grout and indicated that.certain rotating equipment bases sounded hollow which suggested the possible presence of grout voids.

NCR 560 Rev. I was dispositioned to rework all of these grouting discrepancies. This rework consists of pumping grout into holes drilled in equipment bases where bases sound hollow and chipping and repair of grout cracks wider than 1/64 inch.

Other Findings Six additional discrepancies related to equipment hardware were identified and appropriately dispositioned. An equipment pad for a heat exchanger was 3 inches too small, causing shims to be exposed through grouting. An arc strike was identified on a pedestal and leg for a strainer.

L(

~

Two identical heat exchangers were switched in their respective locations. A tank and a pump were 1/16 and 3-3/8 inches off design location, respectively.

A gap of up to 7/32" existed between one leg of a heat exchanger and one portion of the embed upon which the heat exchanger was supported. One vendor weld'on a heat exchanger support leg was oversized such that it created an interference with an anchor bolt washer.

During the equipment retrofit inspection program, deviations from programmatic and documentation requirements were also documented. There were 18 findings that components were released for piping without completing the installation inspection record showing release for piping sign-offs. In each case, initial installation documentation has been reviewed to determine the adequacy of the preparation for piping or the finally connected condition of the piping has been examined to waive the required piping release approval.

f 10 11931 l

b

=...-

k Six pump nozzle welds were completed without preweld QC verification of

-}-.

< nozzle dimensions. Two steam. generator nozzle weld preparations were not non-destructively examined prior to welding. In each case, acceptable measurements or examinations were.ade after welding. Welding was performed

~

on two tanks without appropriate ASME code authorization. Documentation associated with'six pieces of equipment were incomplete or incorrectly altered for which corrections were made. In one case, the vendor's requirement that a i-vendor representative be present during pump unpacking was not met.

A change in plate dimensions for two tank supports was not approved prior to installation. All of the above items were appropriately dispositioned.

Additional discrepancies were identified for lack of documentation for release of equipment for system testing and for lack of documented use of a special lift procedure during heavy equipment setting. The reinspection of equipment under the retrofit program provided a resolution to these discrepancies. No hardware discrepancies resulted from these document deficiencies.

Additional inspections related to mechanical equipment, but not specifically a result of the mechanical equipment retrofit program, were controlled administrative 1y by Procedure QCP-B22 and were performed in conjunction with the retrofit program. These inspections include the shim thickness verification of vendor equipment-to-skid connections; the resolution to CECO NCR 6103 regarding the verification of panel welding, mounting, and concrete expansion anchor details; and equipment maintenance and housekeeping activities relating to NCR 777. Any deficiencies identified during the course of these inspections are not within the scope of the retrofit program and as such are not discussed herein.

.(

11 11931 l

I s

(

IV.

CONCLUSIONS Prior to 1982, PGCo did not effectively implement a program that provided documented evidence of the acceptability of the installation of mechanical equipment. As a result, a procedure PGCo QCP-E22 was developed to control the

-installation of mechanical equipment and to generate appropriate Q.C.

documentation attesting to the acceptability of the installation process.

In order to demonstrate the acceptability of mechanical equipment installed prior to September 1982, this procedure was used to retroinspect as required all previous installations. The results of this retrofit program indicated that most' previous installations were acceptable, notwithstanding the previous lack of documentation.

As a result of these actions, both previously completed mechanical equipment installations and ongoing equipment installation activities can be demonstrated to be in conformance with the requirements of ANSI N45.2.8-1975.

.C The succes'sful implementation of this retrofit program has provided CECO a sound basis for confidence in the acceptability of both the installation of mechanical equipment and the associated documentation genercted to demonstrat e acceptable installation quality. Accordingly, CDCo activities deemed necessary to close IE Report Item 82-05-04 and 55(e) Report 82-07 have been completed and the supporting documentation is available at the plant site for NRC Staff review.

{

12 11931

REFERENCES 1.

W.L. Stiede letter to James G. Keppler; dated September 1, 1982.

2.

IE Report 50-456/82-05 and 50-457/82-05; James G. Keppler letter to James J. O'Connor; dated February 2, 1983.

3.

Cordell Reed letter to James C.* Keppler; dated April 4,1983.

4.

L.O. DelGeorge letter to James G. Keppler; dated July 6, 1984.

5.

IE Report 50-456/84-06 and 50-457/84-06; R.F. Warnick letter to Cordell Reed; dated April 27, 1984.

6.

IE Report 50-456/84-21 and 50-457/84-20; R.F. Warnick letter to Cordell Reed; dated November 20, 1984.

7.

IE Report 50-456/85052 and 50-457/85050; W.S. Little letter to Cordell Reed; dated December 5, 1985.

(

(

13 11931

L; 4-

'ri E

v V

L g

APPENDIX A f-1(

i RETROFIT PROGRAM INSPECTION ATTRIBUTES The inspections'specified for the retrofit program are' documented in procedure QCP-822. The eighteen standard inspection attributes are:

1.

Foundation ' check conce,ete pads, supports, etc. for general condition.

2.

Bolt angularity - check angularity of anchor bolts for perpendicularity with equipment surface. Acceptance allows 3*

angularity or up to 10' angularity using beveled washer.o

. achieve uniform bolting contact.

3.

Concrete expansion anchor documentation - check completion of CEA documentation as specified by PGCo procedures.

4.

. Rough Set - check that equipment has been set in place, properly supported with packaging removed as necessary to permit installation, and aligned with the elevations and coordinate indicated on the location drawing. This check is not required if final set is completed or in process.

4 5.

Final Set - check that equipment is bolted or welded down,

. (.

level, on elevation, and its major openings or axes are located at the proper coordinate as indicated on the location drawing.

Grout complete, torque thread engagement and welding complete and acceptable, must all be checked before final set can be signed off.

6 Torque - anchor bolt torque is checked for either " snug-tight" or other torque values required by the manufacturer or S&L.

7..

Thread engagement - thread engagement is checked that the nut shall be at a minimum, flush with the end of the anchor bolt.

8.

Weld procedure - check for Class I, II, and III equipment requiring welding of component supports that a weld map drawing containing all welding information required by PGCo procedures has been completed.

9.

Grout release - check tnat the superintendent has requested the grout release.

10. Grout complete - check that equipment has been grouted and that

. grout is undamaged.

I 14 11931

(

11.

Release for piping - equipment nozzle designation as shown on a manufacturer's drawing of the equipment shall be listed for release sign-of f.

Those conditions which affect alignment shall be signed-off upon completion of alignment requirements.

12.

Internal cleanliness - internal cleanliness check for foreign material and debris in the equipment is performed at each piping connection to the equipment prior to final connection.

13. 'Driveline cleanliness - che'ck that all areas containing lubricants are clean.

14.

Lubrication complete - check that proper lubricant has been obtained and that all lubrication required by the manufacturer has been completed.

15.

Alignment complete - check that equipment has been properly cold aligned.

16.

Lube cooling Sub-piping complete - check that all sub-piping joints are tight for piping supplied by the manufacturer with the subject equipment.

17.

Equipment 1.D. - check that serial number found on the equipment matches the serial number determined from the MRR and manufacturer's Data Reports.

18.

Externally mounted hardware - check that required externally mounted hardware is in place, free from damage, and properly.

tightened.

In addition to the above standard installation inspection attributes, the Field Engineer may cpecify additional inspection attributes by aseessing equipment manufacturer's installation instructions, project design drawings, project requirements and other applicable pGCo procedures.

Special lifting procedures may also be specified for installation.

QCp-B22 has been revised since 1982 to improve the clarity and documentation of specified inspections. Rev. 8 of that procedure is currently in place for installation of safety related mechanical equipment.

15 11931

+.

?

APPENDIX B DETAILED RESULTS OF THE RETROFIT PROGRAM The attached tables present the detailed documented findings of the Retrofit Program.

These findings are contained in various nonconformance reports (NCRs), field problem reports,(FPRs), information requests (irs), and discrepancy reports (DRs), issued during the-retrofit inspection of the 216 components identified as being in various stages of installation prior to September 1,1982. The retro-fit inspection findings are the result of inspections conducted from September through December 1982 and

' supplemented with additional inspection and documentation review from July to December 1985.

A number of different reporting forms were used e.g. NCR, FPR, IR, or DR, depending on the type of deviation encountered and the type of effort required to achieve conformance with requirements.

Because the program was to establish conformity with FSAR and program regulatory requirements, only the end result has been documented,

-i.e. acceptable equipment installation. This retrofit inspection program is therefore to be distinguished from other reinspection programs, where the focus of the program is to evaluate prior activities. Thus, specific findings have not been recorded in instances where the process of retrofit inspection and re-installation resulted in conformance, regardless of the initially found condition.

i k

16 11931-l 1 --

. Table 1 presents the. type of findings reported and the symbols used 1to represent the classes of findings. Other findings outside these categories are specifically described in words. Table 2 provides the

. complete list of finding for all 216 components inspected and Table 3 shows the distribution of findings by type of finding.

4 9

(

e 17 11931

5.'

TABLE 1 L(-

Symbols Used In Reporting Type of Findings SYMBOL' Description at Finding GR

'No Grout' Release or Grout Release hold point bypassed IC Internal Cleanliness bypassed PR Piping Release bypassed or no piping release sign-off AB Anchor Belt damage or out of tolerance or projection TE Thread engagement PWM No preweld measurement, or not QC verified DOC Documentation filed improperly, or missing initial or dates or wrong data

('

NW Nut and washer concerns, loose nut, wrong nut, missing washer, washer obstruction EL Equip, off location, or wrong component on location TR No test release sign-off HS Anchor bolt hole size tolerances not met HE Anchor bolt hole elongation Sect XI Work not done under ASME Section XI where required MRR Work prior to MRR Approval MT Nozzle end prep not MT examined SLP No Special lifting procedure QC QC hold point bypassed l

18 11931

v -.

TABLE 2

'k Distribution of Installation Inspection Findings For All 216 Components Inspected Component I.D.

  1. Findings Type of Findings OAB01PA OAB01PB~

OAB02DA 3

AB(2), QC OAB02DB 4

AB(2), IC, QC OAB02FB 1AF01PA 1AF01PB 2

HE, bowed piping 2AF01PA 2AF01PB 1

AB 1BR01A 2

IC, DOC.

2BR01A 2

PR, NW 1BR03A 2BR03A OCC01A' 2

GR, grout damage OCC01P 2

PR, IC, 7

1CC01A 4

GR, NW, Grout defect, found. pad not

.\\

completely supporting equipment ICC01PA 1CC01PB 2CC01A 2CC01PA 2CC01PB ICC01T 6

HS, GR, Sect. XI, DOC., Procedure conflict, A/E approv. missing 2CC01T 2

Plate thick. incorrect, Sect. XI ICS01PA 3

GR, PR, PWM 1CS01PB 3

GR, PR, PWM 1CS01T 2CS01PA 1

PWM 2CS01PB 1

PWM 2CS01T ICV 01AA ICV 01AB s

2CV01AA 2CV01AB ICV 01DA ICV 01DB I

ICV 01FA

('

ICV 01FB 19 11931

Distribution of Installation Inspection Findings For All 216 Components Inspejted (Con't)

Component I.D.

  1. Findings Type of Findings ICV 01PA 2

GR, Mnfr. inspection of install not performed ICV 01PB 1

GR 2CV01PA 2

TE, EL 2CV01PB -

1 TE 1CV01T 1

PR 2CV01T ICV 02A 2CV02A ICV 02D 1

IC ICV 02F ICV 02P 2

GR, TE 2CV02P 2

TE (2) 1CV03AA 1

AB ICV 03AB 1

AB 2CV03AA 1

Shim for contact 2CV03AB ICV 03F 2CV03F

-(

ICV 04AA 3

HS, NW, HE 1CV04AB 1

HS 2CV04AA 2CV04AB ICV 05A 1

IC 2CV05A 1

IC 1DG01XA 2

MRR, AB IDG01KB 1

MRR 1DG01SA 20001SA 1DG01SA-C 2DG01SA-C 1DG01SA-D 2DG01SA-D 1D001S8 2DG01SB 1DG01SB-C 2DG01SB-C 1DG01SB-D 2DG01SB-D l

20 11931

'9-s Distribution of Installation Inspection

,[-

Findings For All 216 Components Inspected (Con't)

Q_omponent_I.D.

  1. Findings _

Type of Findings.

ID00lPA 1D00lPB 1D001PC-1D001PD 1D002TA

- 20002TA 1D002TB 2D002TB 1D010T 20010T IFC01A 1

HS 2 K01A 2

IC, AB IFC01P 2FC01P OGWOISA 1

IC OGW0lSB 1

IC OGW0lTA 1

GR OGW0lTB 1

GR

(

OGWOITC 1

GR OGW0lTD 1

GR OGWOITE 1

GR OGWOITF 3

EL, GR, TE 1PL50J' IPL52J OPL53JA OPL53JB IPL53J IPL54J IPL55J IPL56J IPL57J OPL60JA OPL60JB IPL60JD IPL61JC IPL61JD IPL66J IPL67J IPL69J IPL70J IPL71J IPL72J

(>

21 11931

t

k..;.

Distribution of Installation Inspection

- {-

Findings For All 216 Components Inspected (Con't)

Component I.D.

  • Findings._

Type of Findings IPL74J IPL75J IPL76J-'

'IPL81JA 2PL81JA IPL81JB

'2PL81JB IPL82JA 2

PR, IC

-1PL82JB~

2PL82JB IPL84JA 2PL84JA 1PL84JB 2PL84JB 2PL85JB 1PL92J 1RC01BA 1

PR 2RC01BA 1

PR 1RC01BB 3

DOC., MT, PR

.2RC01BB 1

PR IRC01BC 2

MT, PR

(

2RC01BC 1

PR 1RC01BD 1

PR 2TC01BD 1

PR 1RC0lPA 2RC01PA 1RC0lPB 2RC0lPB 1RC0lPC 2RC0lPC 1RC0lPD 2RC01PD 1RH0lPA 2

GR, PWM 2RH01PA' 1

PWM 1RH01PB 1

GR 2RH0lPB 1RH0lSA 2RH0lSA 1RH0lSB 1

PR 2RH0lSB 2

PR, IC

'1RH02AA 4

EL, SLP, IC, PR 2RH02AA 1RH02AB 5

EL, SLP, IC(2), PR 2RH02AB 2

AB, Grt. thick

(

l 22 11931

y.

r

  • 4 -

- 9

(

Distribution of Installation Inspection Findings For All 216 Components Inspected (Con't)

Component I.D.

  1. Findings Type of Findings 1R701S 3

DOC (2), TE 2RYO15 ISIO1PA 3

IC, IC, TE 2SIO1PA-

' 1SIO1PB 2

IC(2)-

2SIO1PB 1

TE ISIO4TA 2SIO4TA ISIO4TB 2SIO4TB 1SIO4TC 2SIO4TC 1SIO4TD 2SIO4TD ISX01FA 2

GR, TR 2SX01FA 2

GR, Arc strike

- ISX01FB 2

GR, TR h

2SX01FB 1

GR ISX01PA 3

GR, TR, AB 2SX01PA ISX01PB 3

GR, TR, work w/o doc.

2SX01PB IVA01SA 3

TE, GR, IC 2VA01SA 2

GR, IC IVA01SB 2

GR, AB 2VA01SB 2

GR, IC IVA02SA 2

GR, IC 2VA02SB IVA02SB 2

GR, AB 2VA02SB 1

GR IVA03SA 1

GR 2VA03SA 1

W IVA03SB 1

GR 2VA03SB 1

GR

- IVA04SA 2

HE, IC 2VA04SA IVA04SB 2

GR, IC 2VA04SB IVA05S 3

TE, IC, W 2VA05S IVA06SA 1

IC

(

2VA06SA 23 11931 L.

'e Distribution of Installation Inspection Findings For All 216 Components Inspected (Con't)

Component I.D.

4 Findings _

Type of Findings IVA07S 2VA07S IVA08S 1

IC 2VA085 IVP01AA IVP01AB-

'IVP01AC IVP01AD OWOO1CA OWOOICB OWOO1PA' OWC 01PB

.OWX05T 1

AB TOTAL 216 Component 156 FINDINGS *

(',

The findings presented in this table do not include findings reported under progransnatic NCRs that wete written to adomss a broad class of related issues such as storage and maintenance ((NCR 777),

cleanliness (NCR 614), panel installation (NCR 6103), and grout inspection (NCR 560).

k 24 11931

{,

=:.

TABLE 3

[:

...(=

DISTRIBUTION OF FINDINGS BY TYPE OF FINDING TorAL FINDINGS = 156

  • TYPE
  1. FINDINGS GR 33 IC 27 PR 18 AB 14 TE 11 PWM 6

DOC.

5

'NW 5

EL 4

TR 4

HS 4

HE 3

SECT XI 2

MRR 2

MT 2

SLP 2

QC 2

(.

OTHERS-Work w/o doc.

1 Arc Strike 1

Bowed piping 1

Proc. conflict, A/E apprv.

Mnfg. inspection 3

Found pad, plate thick, shim for contact, Get defect, Get thick.

5

.t.

The findings presented in this table do not include findings reported under programmatic NCRs that were written to address a broad class of related issues such as storage and maintenance ((NCR 777),

cleanliness (NCR 614), panel installation (NCR 6103), and grout inspection (NCR 560).

k 25 11931

f.

7 APPENDIX C STEAM GENERATOR BOLTING CECO has implemented certain corrective actions specifically addressing the steam generator bolting issue raised by the NRC Staff in IE Report 82-05.

These corrective' actions are described herein.

'The first shipment of steam generator bolts (cap screws) was received at Braidwood on March 10, 1978. These cap screws were supplied by Teledyne Brown as part of the NSSS support package. Byron also l received the same type of cap screws from Teledyne Brown, which was the common supplier of that portion of the NSSS support package for both sites. Between June 24, 1978 and June 14, 1979, a number of these cap screws were shipped between Byron and Braidwood, as current construction needs dictated.

.At Byron some problems were encountered with the installation of the cap screws. As a result, a field change request (FCR 591) was initiated at Byron on November 13, 1978 to resolve those installation difficulties by allowing shortening of the cap screws. To take account of the problem encountered at Byron, the Sargent & Lundy structural drawing that specifies these cap screws at Braidwood (Rev. K of S1112) was modified to incorporate FCR 591, allowing shortening of the cap screws, as necessary, to facilitate installation.

Phillips, Getschow Co. Quality Control personnel inspected all the cap screws in stock at Braidwood and on February 9, 1979 initiated PGCo NCR 334, which required cleaning and special inspections prescribed by i

Westinghouse for the cap screws. Purchase Orders 722186 and 727837 were

(

l 26 i

11931 b

1

'*g m

- issued to Rockwell Engineering Co. on March 27, 1979 and June 14, 1979.

kJ respectively, for the cleaning, special inspection, and shortening of all cap screws on site, both those originally received from Teledyne Brown and those shipped from Byron. These actions were similar to those taken at Byron. The last shipment of cap screws from Rockwell after cleaning, inspection, and shortening was received on site on June 27, 1979. Bolts k

that were considered unacceptable by Rockwell af ter inspection were scrapped and new bo.ts were ordered from Teledyne Brown to take their place. The last shipment of cap screws used for replacements at Braidwood was received on January 1,1982 from Teledyne Brown.

Between May of 1979 and January of 1981 the cap screws were completely trial fit in the Unit 1 and partially trial fit in the Unit 2 steam generators prior to the setting of the steam generators.

Subsequently, it was determined by Phillips, Getschow Co. that some of the new cap screws received from Teledyne Brown required shortening.

During the shortening operation, which was carried out by Phillips, Getschow Co., the material heat traceability identification numbers on 19 cap screws were not properly transferred. On October 13, 1981, PGCo initiated POCO NCR 612 to correct this condition.

It was determined that all 19 cap screws came from the same material heat and the disposition of NCR 612 was to reapply the proper heat number.

During installation of the cap screws, certain problems were encountered. On December 12, 1981, CECO NCR 332 was initiated to document the fact that a number of cap screws could not be fully engaged. NCR 332 also referenced the same loss of material heat traceability identification subsequently corrected under NCR 612, as k

i 27 11911 l

c

.p.

.: e_

described abov=.

The disposition noted on NCR 322 required the removal,

,I reinspection, and replacement of all steam generator cap screws which could not be fully engaged. In addition, after removal of the bolts, the

'NCR required inspection of the heli-coils, which are threaded inserts that can be removed and replaced if installation problems occur.

A routine NRC safety inspectidn was conducted during the period April 19 through July 20, 1982, and a special NRC inspection was conducted on September 8-10, 1982, of activities at Braidwood Station, Units 1 and 2.

The results of the inspections were discussed during an enforcement conference conducted at the NRC Region III office on August 31, 1982, and at the Commonwealth Edison Company Corporate offices in Chicago Illinois on November 19, 1982. The reports setting forth the results of the inspections and the enforcement conferences are documented in Inspection Report 50-456/82-05; 50-457/82-05. As a result of these

(

inspections and as discussed at the enforcement conferences, the NRC

' Inspector expressed concern in relation to the installation of the Steam Generator cap screws. This concern, as stated in NRC inspection report 82-05, dealt with the areas of damage to the cap screws, installation methods, cap screw traceability, cap screw. installation procedures and timeliness of corrective actions regarding the cap screws.

In response to this concern, Commonwealth Edison committed to remove and reinspect all the cap screws and replace the ones which were not acceptable. Phillips, Getschow Procedure POCP-33 controlled the cap screw removal and Procedure PGCP-34 their reinstallation. Additionally, the bolt holes and heli-coils were also to be inspected and the heli-coils replaced if necessary. This inspection and replacement were also controlled by PGCP-33 and PGCP-34, respectively.

28 11931

3 Concurrently, C To NCR 413 documented some problems with the alignment between the steam generator pads and the vertical supports which are joined by the cap screws. The disposition of NCR 413 directed that the top support plates be slotted to facilitate bolt installation.

The disposition of this NCR, when finally implemented, completed resolution of the cap screw issue ' The removal and reinstallation of the Unit 2 bolts started in October of 1982 and finished in April of 1983.

The removal and reinstallation of the Unit 1 bolts started in August of 1983 and finished in January of 1984.

The other area of concern which had been expressed by the NRC during the previously referenced inspections and enforcement conferences dealt with traceability documentation for cap screws which were transferred from Byron to Braidwood and from Braidwood to and from Rockwell Engineering. Records exist on site which establish traceability and control of the steam generator support cap screws transferred to and/or from Braidwood and track those bolts and their respective movements back and forth. At the time of NRC Inspection 82-05, the proper records correlationhadnotbeenaccomplishdd,sothatthedatawasnotreadily auditable by the NRC inspector. A correlation to establish traceability of the steam generator bolts utilized at Braidwood has since been accomplished. Results of this correlation establish that, for all bolts transferred to and/or from Braidwood, records were maintained and exist today which demonstrate control and traceability. No transfers of bolts between Braidwood and either Byron or Rockwell Engineering occurred after June 27, 1979. The only steam generator bolts received at Braidwood after June 27, 1979 were new purchases from Teledyne Brown Engineering.

29 11931

f-.

e D-

-(

The correlation for all steam generator bolts utilized at Braidwood is complete at this time.

I Through the above cap screw traceability correlation and the documented bolt removal / reinstallation in accordance with PCCo procedures pGCP-33 and 34, the acceptability of all 384 bolts currently installed in the Braidwood Unit 1 and Unit 2 Steam Generators has been positively affirmed.

The NRC has reviewed the documentation developed as part of the cap screw installation review and "found the documentation to be accurate, reflecting acceptable field installations". The NRC closed the inspection report finding (82-05-01) related to these cap screws in IE Report 50-456/85052 and 50-457/85050 (Reference 7).

(

30 11931