ML20137F264

From kanterella
Jump to navigation Jump to search
Submits Notification of Upcoming Shipment of Seven Model 30B Cylinders Inside Overpocks containing:RA,UF6,fissile (Containing More than 1% U-235),7,UN2977,radioactive Matl (U-235,U-238) Approx UF6 weight:15,940 Kgs,To Columbia,Sc
ML20137F264
Person / Time
Site: 07001426
Issue date: 02/03/1997
From: Mclaughlin J
TRANSNUCLEAR, INC.
To: Bennington G
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
TNY-97019-6, NUDOCS 9704010034
Download: ML20137F264 (2)


Text

UZ-Ud-9'l 1 2 : U '( P M TRANSNUCLEAR 1 N C.

F01

+4 su Da o 399-3 gen TRANSNUCLEAR, INC.

February 3,1997 m oral e,a a n

Mrs. Gloria Bennington O h O-O / / eQ 6 Division of Safeguards and Transportation U.S. Nuclear Regulatory Commission Washington, DC 20555 (Rc Transnuclear reference: TNY 970i'9D

~

Advance notification for an import shipment of nuclear material from countrics that are not party to the Convention on the Physical Protection of Nuclear Material This letter constitutes Transnucler.r Inc.'s advance notification to the USNRC in compliance with the requirements as outlined in 10 CFR 73.74(a)(1)(2) for an import shipment of low

. strategic significance material from Countries that are not party to the Convention on the Physical Protectica of Nuclear Material.

Details of this shipment as required in 10 CFR 73.74(a)(3) are as follows:

73,74(a)(3)(i) Data:

Importer of Record Receiving Facility COGEMA, Inc.

Westinghouse Nuclear Fuels Division 7401 Wisconsin Avenue 5801 Bluff Road Bethesda, MD 20814 Columbia, SC 29209 301/986-8585 803/776-2610 Shipping Facility Carriers COGEMA Picisclattc Atlantic Container Lines B.P.16 50 Cragwood Road 26700 Pierrelatte, France So. Plainticid, NJ 07080 33 7550 4000 908/668-5556 Transport Coordinator AND Transnuclear, Inc.

Pacer Transportation Four Skyline Drive 725 North Point Road IIawthome, NY 10532 Baltimore, MD 21237 914/347-2345 410/325-3600 t

D M03 h

FOUR SKYLINE DRIVE

  • HAWTHORNE, NEW YORK 10532-2176 TELEPHONE: 914 347-2345. FAX: 914 347 2346 310009 silytHMipEEI4 9704010034 970203

^'

PDR ADOCK 07001426 C

PDR

omi a c..

m rus

+t-Odo39 %

m

~

@p@g si Page 2 of 2 February 3,1997 TNY 97019-6 73.74(a)(3)(li) Data: Physical description of shipment:

Seven model 30B cylinders inside overpacks containing:

RQ, UkAN1UM NhxAPLUORIDE, FISSILE (containing more than 1 % U235), 7, UN2977, Radioactive Material (U235,U238) solid, UF6. Approximate UF6 weight: 15,940 l

kgs. Approximate U weight: 10,780 kgs enriched to max. 4.95%. Approximate weight i

U235: 540 kgs 73.74(a)(3)(iii)(iv)(v) Data:

MODE O RIGIN(0),TR A NSFER(T),

ROUTE DATE/ TIME OF ARRIVAL COUNTRY /ENROUTE(C/E)&

(A) & DEPARTURE (D) AT DESTINATION (D) POINTS EACH POINT Rail Pierrelatte, FRANCE standard rail (D)

February 28,1997 0800 - 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> Antwerp, BELGIUM (A) March 3,1997 Ocean.

standard ocean 0800 - 2339 hours0.0271 days <br />0.65 hours <br />0.00387 weeks <br />8.899895e-4 months <br />

  • " ~ ' * '

(D)

March 5,1997 Liverpool, ENGLAND (A/D) March 7,1997 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Halifax, CANADA (A/D) March 16,1997 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Port Elizabeth, NJ (AID) March 18, 1997 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Baltimore, MD (A/D) March 20,1997 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Portsmouth, VA (A)

March 21,1997 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Amval at the receiving facility is estimated to be between 0700 hours0.0081 days <br />0.194 hours <br />0.00116 weeks <br />2.6635e-4 months <br /> and 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> on March 26,1997.

This shipment will meet the levels of physical protection specified in Appendix E (Annex 1).

Yours tmly, OO%YY n McLaughlin Traffic Coordinator u