ML20137F258

From kanterella
Jump to navigation Jump to search
Notification of 970414-18 Meeting W/Util in Monroeville,Pa to Discuss Design Calculations Supporting Documents for Structural Modules & Related Issues for AP600 Standard Plan
ML20137F258
Person / Time
Site: 05200003
Issue date: 03/27/1997
From: Diane Jackson
NRC (Affiliation Not Assigned)
To: Quay T
NRC (Affiliation Not Assigned)
References
NUDOCS 9704010026
Download: ML20137F258 (3)


Text

.

i March 27, 1997

)

MEMORANDUM TO: Theodore R. Quay, Director i

Standardizatioa Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation FROM:

Diane T. Jackson, Project Manager original signed by:

Standardization Pr.1 ject Directorate Division of Reactor Program Management Office of Nuclear Re. actor Regulation

SUBJECT:

NOTICE OF MEETING WITil WESTINGHOUSE TO DISCUSS STRUCTURAL MODULES FOR THE AP600 STANDARD REACTOR DESIGN DATE AND TIME: April 14, 1997 - 1 p.m. - 5 p.m.

April 15 through 18, 1997 - 8 a.m. - 5 p.m.

LOCATION:

Westinghouce Electric Corporation Westinghouse Energy Center 4350 Northern Pike i

Monroeville, PA 15146-2808 PURPOSE:

The purpose of this meeting is to review the design calculations supporting documer.ts for the structural modules and related issues for the AP600 standard plant.

A draft agenda is attached.

PARTICIPANTS *:

EC WESTINGHOUSE G. Bagchi R. Mandava T. Cheng R. Orr D. Jackson D. Lindgren, et al.

J. Braverman (Consultant), et al.

Docket No.52-003

Attachment:

As stated cc w/ attachment:

See next page

  • Meetings between NRC technical staff and applicants or licencees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to the " Commission Policy Statenent on Staff Meetings Open to the Public," 59 Federal Reaister 48344, 9/20/9(. However, portions of this staff meeting may be closed to protect Westinghouse proprie-j tary information. Members of the public who wish to attend should contact I

Diane Jackson (NRC) at (301) 415-8548, or Don Lindgren (Westinghouse) at

{

(412) 374-4856.

DISTRIBUTION:

\\

See next page h

n

...,,.,ME:

A:ECG4 14.N0T DOCUMENT NA m.

. w m wm c. co,,

nhoui.it.chmenu.nclosur. *P = Copp with.ft. chm.ntl.nclosur.

"N" = No copy 0FFICE PM:PDST:D R D:PDST:DRPM l

NAME DTJackson M TRQuay @

DATE d /Ji/97

(>

3/n/97 1

^"lCIAL RECORD COPY 970401o026 970327 i

PDR ADOCK 05200003 A

PDR j

i i

Westinghouse Electric Corporation Docket No.52-003 cc: Mr. Nicholas J. Liparulo, Manager Mr. Frank A. Ross Nuclear Safety and Regulatory Analysis U.S. Department of Energy, NE-42 1

Nuclear and Advanced Technology Division Office of LWR Safety and Technology Westinghouse Electric Corporation 19901 Germantown Road P.O. Box 355 Germantown, MD 20874 Pittsburgh, PA 15230 Mr. Ronald Simard, Director Mr. B. A. McIntyre Advanced Reactor Program Advanced Plant Safety & Licensing Nuclear Energy Institute Westinghouse Electric Corporation 1776 Eye Street, N.W.

Energy Systems Business Unit Suite 300 Box 355 Washington, DC 20006-3706 Pittsburgh, PA 15230 Ms. Lynn Connor Ms. Cindy L. Haag Doc-Search Associates Advanced Plant Safety & Licensing Post Office Box 34 Westinghouse Electric Corporation Cabin John, MD 20818 Energy Systems Business Unit Box 355 Mr. James E. Quinn, Projects Manager Pittsburgh, PA 15230 LMR and SBWR Programs GE Nuclear Energy Mr. M. D. Beaumont 175 Curtner Avenue, M/C 165 Nuclear and Advanced Technology Division San Jose, CA 95125 Westinghouse Electric Corporation One Montrose Metro Mr. Robert H. Buchholz 11921 Rockville Pike GE Nuclear Energy Suite 350 175 Curtner Avenue, MC-781 Rockville, MD 20852 San Jose, CA 95125 Mr. Sterling Franks Barton Z. Cowan, Esq.

U.S. Department of Energy Eckert Seamans Cherin & Mellott 1

NE-50 600 Grant Street 42nd Floor 19901 Germantown Road Pittsburgh, PA 15219 Germantown, MD 20874 Mr. Ed Rodwell, Manager Mr. S. M. Modro PWR Design Certification Nuclear Systems Analysis Technologies Electric Power Research Institute Lockheed Idaho Technologies Company 3412 Hillview Avenue Post Office Box 1625 Palo Alto, CA 94303 Idaho Falls, ID 83415 Mr. Charles Thompson, Nuclear Engineer AP600 Certification NE-50 19901 Germantown Road Germantown, MD 20874

1

.e AP600 STRUCTURAL MODULES MEETING APRIL 14 THROUGH 18, 1997 DRAFT AGENDA i

I.

Introduction II.

Technical Review / Audit and issue resolution e

Calculation review e

Shield building roof structural analyses and design e

Cable tray damping Air baffle flow induced forces e

Other related isscos F

III. Open Item status review V.

Summary f

i I

l Attachment

r, j

i I

DISTRIBUTION: Memorandum to Theodore R. Quay. Dated: March 27, 1997 Docket File PUBLIC PDST R/F 1

SCollins/FMiraglia, 0-12 G18 AThadani, 0-12 GIS RZimmerman, 0-12 G18 TMartin MLSlosson TJKenyon DTJackson WCHuffman JMSebrosky 1

WDean, 0-17 G21 JMoore, 0-15 B18 ACRS (11)

BSheron, 0-7 D24 Glainas, 0-7 D24 4

GBagchi, 0-7 HIS 4

JBrammer, 0-7 HIS Tcheng, 0-7 HIS RBailey/BGray, 0-2 B2 PMNS (e-mail) i OPA (e-mail) 4

)

i I

I CS/,

Of 310034 4