Ack Receipt of from TE Abney Responding to Request for Reevaluation of Scope of Valves Included in Plant GL 89-10 Program.Requests That NRC Be Notified If Program Will Not Be Completed by Proposed Insp Date
ML20137E196
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 03/18/1997
From: Fredrickson P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Kingsley O
TENNESSEE VALLEY AUTHORITY
References
GL-89-10, NUDOCS 9703270093
Download: ML20137E196 (3)


Text

_

MARCH 18, 1997 Tennessee Valley Authority ATTN: Mr. Oliver D. Kingsley, Jr.

President, TVA Nuclear and Chief Nuclear Officer 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801

SUBJECT:

INSPECTOR FOLLOWUP ITEM 50-260/95-19-01 AND 50-296/95-19-01 REDUCED SCOPE OF VALVES IN GENERIC LETTER 89-10 PROGRAM

Dear Mr. Kingsley:

Thank you for the letter of January 6,1997, from Mr. T. E. Abney, Browns Ferry Manager of Licensing and Industry Affairs, responding to our request that you reevaluate the scope of valves included in your Browns Ferry Generic Letter 89-10 program. The changes committed to in Mr. Abney's letter are considered adequate to address our concems on this subject.

We noted that several valve testing dates provided in your letter indicated that your implementation of Generic Letter 89-10 may not have been completed by the date of a closure inspection planned for July 14,1997. However, based on a telephone conversation with Mr. John Elmerick and others of your staff on March 17,1997, we understand that you expect to have completed implementation of Generic Letter 89-10 by the date of the inspection. Please notify us, if in the future, you find that your program will not be fully implemented by our proposed inspection date.

We appreciate your cooperation in this matter.

Sincerely, ORIGINAL SIGNED BY PAUL FREDRICKSON Paul E. Fredrickson, Chief Special Inspection Branch Division of Reactor Safety Docket Nos. 50-259, 50-260, 50-296 License Nos. DPR-33, DPR-52, DPR-68 cc:

O. J. Zeringue, Senior Vice President, Nuclear Operations Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 (cc cont'd - See page 2) g

g g

g 9703270093 970318 S"^

8!!'

j9L

TVA 2

(cc cont'd)

Jack A. Bailey, Vice President Engineering & Technical Services Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 C. M. Crane Site Vice President Browns Ferry Nuclear Plant Tennessee Valley Authority P. O. Box 2000 Decatur, AL 35602 Raul R. Baron, General Manager Nuclear Assurance and Licensing Field, Manager Tennessee Valley Authority 4J Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Masoud Bajestani, Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P. O. Box 2000 Decatur, AL 35609 Pedro Salas, Manager Licensing and Industry Affairs Tennessee Valley Authority 4J Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. Timothy E. Abney, Manager Licensing and Industry Affairs Browns Ferry Nuclear Plant Tennessee Valley Authority P. O. Box 2000 Decatur, AL 35609 (cc cont'd - See page 3)

i TVA 3

(cc cont'd)

General Counsel Tennessee Valley Authority ET 10H 400 West Summit Hill Drive Knoxville, TN 37902 Chairman Limestone County Commission 310 West Washington Street Athens, AL 35611 State Health Officer Alabama Dept. of Public Health 434 Monroe Street Montgomery, AL 36130-1701 Distribution:

J. R. Johnson, Rll M. S. Lesser, Ril J. F. Williams, NRR F. J. Hebdon, NRR S. E. Sparks, Rll H. L. Whitener, Ril C. F. Smith, Rll E. D. Testa, Ril D. H. Thompson, Ril J. H. Moorman, Rll PUBLIC NRC Senior Resident inspector U.S. Nuclear Regulatory Comm.

10833 Shaw Road Athens, AL 35611 i

Orrtct off noS off.no!

pit noo

$1GNATURE NAME GIRARD FRE m.50N LESSER DATE 03 / fi / 97 03 / l [ / 97 03 / /I / 97 03 /

/ 97 03 /

/ 97 03 /

/ 97 COPY?

- [ Yl7 NO YES NO YES NO YES NO YES NC YES NO UffICIAL ktCUkD CDPY DOCUMtNi NAMt: 5:tUkbi5iB\\ M \\bi5CUPE.ACK l

. _ _ - - - - - - - - - -