. _

_

-

_

. _. _.

_. _ _

_.. _ _.

__

___._

_

e

-

Appendix NOTICE OF VIOLATION i

United States Steel Corporation License No. 12-13386-02

.

As a result of the inspection conducted on June 17 through July 11, 1985, and in accordance with the General Policy and Procedures for NRC Enforcement Actions, (10 CFR Part 2, Appendix C), the following violations were identified:

!

1.

License Condition No. 16 requires that licensed material be possessed and used in accordance with the statements, representations, and procedures contained in application dated April 27, 1981.

Item 15 of the referenced application requires the radiation safety officer. to perform quarterly physical inventories.

Contrary to the above, quarterly physical inventories have not been performed.

Specifically, the last inventory was performed in 1983.

This is a Severity IV violation (Supplement VI).

2.

10 CFR 20.207(b) states that licensed materials in an unrestricted area l

and not in storage shall be tended under the constant surveillance and j

immediate control of the licensee.

Contrary to the above, licensed materials in an unrestricted area were not under the constant surveillance and immediate control of the licensee. Specifically, two cesium-137 gauges and one americum-241 gauge l

were unaccounted for in an unrestricted area of the licensee's facility for l

at least one year.

This is a Severity Level IV violation (Supplenent IV).

,

Pursuant to the provisions of 10 CFR 2.201, you are required to submit to

,

l this office within thirty days of the date of this Notice a written statement l

or explanation in reply, including for each item of noncompliance:

(1) cor-

.rective action taken and the results achieved; (2) corrective action to be l

taken to avoid further noncompliance; and (3) the date when full compliance j

will be achie.ved. Consideration may be given to extending your response time l

for good cause shown.

.

'

'

/'

\\

.

c AUG 2 01985 g

g

_

Dated D. G. Wieddman, Chief Nuclear Materials Safety Section 1 l

l 0508230113 850820 REG 3 LIC30 12-13386-01 PDR