ML20137D909

From kanterella
Jump to navigation Jump to search
PNO-TMI-86-001:on 860112,licensee Transferred First Three Loaded Fuel Canisters Out of Reactor Bldg Into Fuel Handling Bldg.Canisters Loaded W/Core Debris.Highest Radiation Level on Transfer Shield Surface Was 20 M/H
ML20137D909
Person / Time
Site: Crane 
Issue date: 01/13/1986
From: Cowgill C, Myers L, Travers W
Office of Nuclear Reactor Regulation
To:
References
PNO-TMI-86-001, PNO-TMI-86-1, NUDOCS 8601170118
Download: ML20137D909 (1)


Text

a 50320-860113 January 13, 1986 '

NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE-PNO-TMI-86-01 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without verifi-cation or evaluation and is basically all that is known by NRC staff on this date.

Facility: GPU Nuclear Corporation Licensee Emergency Classification:

Three Mile Island, Unit 2 X

Not Applicable Docket Number 50-320

Subject:

FIRST CORE DEBRIS REMOVED FROM TMI-2 REACTOR VESSEL On January 12, 1986, at approximately 1:00 PM, the licensee transferred the first three loaded fuel canisters out of the Reactor Building (RB) into the Fuel Handling Building (FHB). The canisters were, beginning on October 30, 1985, loaded with core debris (o.g., end fittings, control rod spiders, fuel pins). The canisters were sealed, dewatered and individually transferred from the reactor vessel by a shielded canister handling bridge to the fuel transfer canal inside the RB. The canisters were then transported to the Fuel Handling Building via a modified fuel transport system and placed in underwater fuel canister storage racks located in the "A" fuel pool. The highest direct radiation level on the surface of the transfer shield during transfer was 20 mR/hr. There was no increase in airborne contamination levels in the RB and FHB as a result of these activities.

NRC site Radiation Specialist inspectors witnessed the transfer activities.

This preliminary notification is issut.d for information only and the NRC plans to c:ntinue monitoring events as they occur. The Commonwealth of Pennsylvania has been notified.

n Lyks590-1141

. h 0-ll20 C. Cow 1

590-1123 W. Tra

Contact:

Distribution:

H.St.f.44 MNBBl'.IT Phillips l'.37 E/W 1 f t Willste 1:f 5 AirRightslllf Chairman Fal ladino E00 NRR IE NMSS SP Comm. Zeck PA OIA RES M. Masnik Com. Roberts MPA AE00 Comm. Asselstine ELD INP0 2.i 10 MAIL:

Comm. Bernthal NSAC st. s) DCS Processing SECY R:I llpA, R:I! l*l 7 R:III llRo ADM:DMB ACRS R:IV-]RAR:V _l:2 6 OELD:

CA J. Tourtellotte PDR 00T:(Trans. Only) 9601170110 860113 M.T 001 PDR

)

E 3'!