P REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE HQ 1 NR-8083-D-802-S DATE: March 17, 1997 PACE 1 OF 4 DEVICE TYPE:
Gamma Indicator Device MODEL:
Tell-Tale Pot (TT155) l MANUFACTURER / DISTRIBUTOR:
C.S. Products (Testing Equipment) Ltd.
Unit 2, Willis Road Totnes Industrial Estate l
Totnes, Devon, TQ 9 5XN England SEALED SOURCE MODEL DESIGNATION:
Amersham Corp.
Source Model CDC.805 i
ISOTOPE:
MAXIMUM ACTIVITY:
Cesium-137 10 mil 11 curies (0.37 GBq)
Depleted Uranium 1.5 lbs. (0.68 kg) i LEAK TEST FREQUENCY: 6 months PRINCIPAL USE:
(D) Gamma Gauge CUSTQM DEVICE:
Y YES NO CUSTQM USER:
Commercial Resins Company j
2001 N.
170th East Avenue Tulsa, OK 74116 j
9703260144 970317 PDR RC SSD PDR
l REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE HQ.1 NR-8083-D-802-S DATE: March 17, 1997 PACE 2 OF 4 DEVICE TYPE:
Gamma Indicator Device DESCRIPTION:
The Tell-Tale Pot (TT155) is fitted into a holder for a low activity tracker source fitted into the crawler body.
The Tell-Tale Pot is then used simply for the purpose of locating the 4
crawler's position within the pipe, with the aid of a radiation j
survey neter,. in case of " crawler" breakdown.
The construction i
of the device is as follows: First there is the center casing or 1
the " pill holder" which is made of stainless steel with maximum j
dimensions of 1.695 in. (4.31 cm) long and 1.625 in.
i (4.13 cm) in diameter.
Second, there is the source itself, l
encased within a depleted uranium pellet.
This is fitted
]
directly into the pill holder and tightly sealed with a stainless steel cap forming a stainless steel pellet, thus making the TT155 i
j device.
l This device is currently in storage pending disposal.
l LABELING:
I l
The TT155 device is etched with labeling that meets the requirements of Sections 20.1901 and 20.1904 of the 10 CFR.
l DIAGRAM:
i See Attachment 1.
CONDITIONS OF NORMAL USE:
The Tell-Tale TT155 was only subjected to ambient environmental pressure and temperature.
Only minimal vibrations are associated with the use of the crawler unit.
PROTOTYPE TESTING:
The source was tested and achieved an ANSI N452 Classification of 77C64544.
The device initially was not tested, but had been used in England for at least 2 years without any reported incidents.
...... - - -. - - -.. -. -.. - - - ~ _
1 REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE ML.1,NR-8083-D-802-S DATE: March 17, 1997 PAGE 3 OF 4 DEVICE TYPE:
Gamma Indicator Device EXTERNAL RADIATION LEVELS:
The dose rate in the beam path for a 10 aci source is 36 ren/hr (360 mSv/hr) at 2 in. (30 cm).
The dose rate on the side surface of the TT155 is 10 mrem /hr (0.10 mSv/hr).
Dose rates at varying distances from the path calculated from the manufacturer's reported data are:
Distance Dona Rata par 10 mci Sourca 2 in (5 cm) 1290 Rem /hr (12.9 mSv/hr) 11.8 in (30 cm) 36 Rem /hr (0.36 mSv/hr) i 39.4 in (100 cm) 3.2 Rem /hr (0.032 mSv/hr)
OUALITY ASSURANCE AND CONTROL:
Custom Devices do not require quality control programs because they are built to the unique specification of the user.
]
T,TMTTATIONS AND/OR OTHER CONSIDERATIONS OF USE:
- The device is authorized for possession only by the custom user pending disposal.
- The device shall be leak tested at 6 months intervals using techniques capable of detecting 0.005 microcuries of removable contamination.
1
- Handling, storage, use, transfer, and disposal: To be determined by the-licensing authority.
- This registration sheet and the information contained within the references shall not be changed without the written consent of the NRC.
j SAFETY ANALYSIS
SUMMARY
Based on our review of the information and test data cited below, we conclude that the TT155 design is acceptable possession by the custom user.
j
t REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE HL.J. NR-8083-D-802-S DATE: March 17, 1997 PACE 4 OF 4 DEVICE TYPE:
Gamma Indicator Device
REFERENCES:
l The following supporting documents for the TT155 Pot device are hereby incorporated by reference and are made a part of this registry document.
- Resource Engineering and Manufacturing Co. letter dated June 21, 1984.
- R.E.EM. Co. amended application letter dated May 14, 1984.
- C.S.
Products (Testing Equipment) Ltd. letter dated May 30, 1984.
- Commercial Resins Company letter dated November 21, 1996, with enclosure, therefore.
ISSUING AGENCY:
U.S. Nuclear Regulatory Commission Date:
March 17, 1997 Reviewer:
/ John W.
Lubinski Date:
March 17, 1997 Concurrence:
4
"' Steven L.
Baggett j
i
- r. - -
... _. _.. =.
m i
i i
i i
i REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICEo SAFETY EVALUATION OF DEVICE i
l HQ1 NR-8083-D-802-S DATE: March 17, 1997 ATTACHMENT 1 7
_N.-
DELPhw 2.
~~z m
9,n 3.
smc_D
~
4, CAP l
s.
-w ze, w. s. L l
i 5
3 l
t' /1 y f
,,\\
-k-f - - -
/
\\
//N i
- V,/
\\
v-s
/
//
x f </
x
/
x 4
~
/ so< /'
/
- A N'
\\,y a
l,l y,
1
\\
[/
u[\\-
\\
N 4
i s
~
\\
1/
~Q mm s
s TELL TA E 65 M5E rnb \\[
Scelt a:l i
PAGE1 NRC FORM 567 U. S. NUCLEAR RE;ULATORY COMMISSION um p
j REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION j
INSTRUCTIONS: Sen.1 this request AND a copy of all related letters / applications and drawings to: The Sealed Source Safety Section, ATT OWFN Mall Stop 6 H3. Change the Ucense Tracidng System milestone to 19 and assign to reviewer code 14.
i NOTE: Retain a copy of this request with the application and background files.
REQUESTER' REGION /LOCATlON:
M li 11 111 IV V
HQ R LFDCB s
l TELEPHONE NUMBER DATE TYPE OF ACTION REQUESTED (Check as appropriate) i APPUCANTS NAME SOURCE REVIEW AMENDMENT OF OMh7 c/C//J /
- d. Sin (
REGISTRATION SHEET MAL CONTROL NUMBER (S)
DEVICE REVIEW N B S)
/07_
LmudAPPUCATION TE UCENSE NUMBER (S)
CUSTOM REVIEW Mb8N M
- A~O b
ll a2l
~~":
p Ai no nu E. 4vE.
fu/.sai oK 9M j
FOR SSSS USE ONLY n
b NPS C&lidet eemM/
b' '
% -HL REVIEWER MODEL NUMBERS g/g NUMBER ASSIGNED i
DATE RECENED DATE ASSIGNED
/
DATE TO FEES
//
/
FM
//
7 b
i TYPE OF ACTION /(indicate % number of each type)
(
l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM)
SOURCE (9C)
DEVICE (9A)
SOURCE (90)
DEVICE (9B)
NEW NEW NEW NEW j
AMENDMENT d MENDMENT AMENDMENT AMENDMENT i
{
go SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED 1
) OTHER (Spedty) 4 TOTAL NUMBER OF NOTES i
REVIEW HOURS
- 44. >
NUMBER OF DEFICIENCY LETTERS NUMBER OF DEFICIENCY CALLS FOR BILLING PURPOSES ONLY NAME CHANGE ADDRESS CHANGE NEW REGSTRATION -
] PRODUCT INACTE -
ADD TO BILLING REMOVE FROM BILLING FOR FEE USE ONLY TYPE OF FEE FEE CATEGORY b
)
]9A 98 9C 9D e
AMOUNT RE CHECK NUMBER MATANN UPDATED
[
_ j n
- AS REQUIRED
,g DATE OF g LOG f f JW _j TSYS PDATED APPROVED BY
/ h l
DATE RETURN DATE g
4f) -
l T/ 3//
COMutNTS
[
t NRC FORM 567 (843)
@ lOl N g,
t