P REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE HQ 1 NR-8083-D-802-S DATE: March 17, 1997 PACE 1 OF 4 DEVICE TYPE:

Gamma Indicator Device MODEL:

Tell-Tale Pot (TT155) l MANUFACTURER / DISTRIBUTOR:

C.S. Products (Testing Equipment) Ltd.

Unit 2, Willis Road Totnes Industrial Estate l

Totnes, Devon, TQ 9 5XN England SEALED SOURCE MODEL DESIGNATION:

Amersham Corp.

Source Model CDC.805 i

ISOTOPE:

MAXIMUM ACTIVITY:

Cesium-137 10 mil 11 curies (0.37 GBq)

Depleted Uranium 1.5 lbs. (0.68 kg) i LEAK TEST FREQUENCY: 6 months PRINCIPAL USE:

(D) Gamma Gauge CUSTQM DEVICE:

Y YES NO CUSTQM USER:

Commercial Resins Company j

2001 N.

170th East Avenue Tulsa, OK 74116 j

9703260144 970317 PDR RC SSD PDR

l REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE HQ.1 NR-8083-D-802-S DATE: March 17, 1997 PACE 2 OF 4 DEVICE TYPE:

Gamma Indicator Device DESCRIPTION:

The Tell-Tale Pot (TT155) is fitted into a holder for a low activity tracker source fitted into the crawler body.

The Tell-Tale Pot is then used simply for the purpose of locating the 4

crawler's position within the pipe, with the aid of a radiation j

survey neter,. in case of " crawler" breakdown.

The construction i

of the device is as follows: First there is the center casing or 1

the " pill holder" which is made of stainless steel with maximum j

dimensions of 1.695 in. (4.31 cm) long and 1.625 in.

i (4.13 cm) in diameter.

Second, there is the source itself, l

encased within a depleted uranium pellet.

This is fitted

]

directly into the pill holder and tightly sealed with a stainless steel cap forming a stainless steel pellet, thus making the TT155 i

j device.

l This device is currently in storage pending disposal.

l LABELING:

I l

The TT155 device is etched with labeling that meets the requirements of Sections 20.1901 and 20.1904 of the 10 CFR.

l DIAGRAM:

i See Attachment 1.

CONDITIONS OF NORMAL USE:

The Tell-Tale TT155 was only subjected to ambient environmental pressure and temperature.

Only minimal vibrations are associated with the use of the crawler unit.

PROTOTYPE TESTING:

The source was tested and achieved an ANSI N452 Classification of 77C64544.

The device initially was not tested, but had been used in England for at least 2 years without any reported incidents.

...... - - -. - - -.. -. -.. - - - ~ _

1 REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE ML.1,NR-8083-D-802-S DATE: March 17, 1997 PAGE 3 OF 4 DEVICE TYPE:

Gamma Indicator Device EXTERNAL RADIATION LEVELS:

The dose rate in the beam path for a 10 aci source is 36 ren/hr (360 mSv/hr) at 2 in. (30 cm).

The dose rate on the side surface of the TT155 is 10 mrem /hr (0.10 mSv/hr).

Dose rates at varying distances from the path calculated from the manufacturer's reported data are:

Distance Dona Rata par 10 mci Sourca 2 in (5 cm) 1290 Rem /hr (12.9 mSv/hr) 11.8 in (30 cm) 36 Rem /hr (0.36 mSv/hr) i 39.4 in (100 cm) 3.2 Rem /hr (0.032 mSv/hr)

OUALITY ASSURANCE AND CONTROL:

Custom Devices do not require quality control programs because they are built to the unique specification of the user.

]

T,TMTTATIONS AND/OR OTHER CONSIDERATIONS OF USE:

  • The device is authorized for possession only by the custom user pending disposal.
  • The device shall be leak tested at 6 months intervals using techniques capable of detecting 0.005 microcuries of removable contamination.

1

  • Handling, storage, use, transfer, and disposal: To be determined by the-licensing authority.
  • This registration sheet and the information contained within the references shall not be changed without the written consent of the NRC.

j SAFETY ANALYSIS

SUMMARY

Based on our review of the information and test data cited below, we conclude that the TT155 design is acceptable possession by the custom user.

j

t REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE HL.J. NR-8083-D-802-S DATE: March 17, 1997 PACE 4 OF 4 DEVICE TYPE:

Gamma Indicator Device

REFERENCES:

l The following supporting documents for the TT155 Pot device are hereby incorporated by reference and are made a part of this registry document.

  • Resource Engineering and Manufacturing Co. letter dated June 21, 1984.
  • R.E.EM. Co. amended application letter dated May 14, 1984.
  • C.S.

Products (Testing Equipment) Ltd. letter dated May 30, 1984.

  • Commercial Resins Company letter dated November 21, 1996, with enclosure, therefore.

ISSUING AGENCY:

U.S. Nuclear Regulatory Commission Date:

March 17, 1997 Reviewer:

/ John W.

Lubinski Date:

March 17, 1997 Concurrence:

4

"' Steven L.

Baggett j

i

r. - -

... _. _.. =.

m i

i i

i i

i REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICEo SAFETY EVALUATION OF DEVICE i

l HQ1 NR-8083-D-802-S DATE: March 17, 1997 ATTACHMENT 1 7

_N.-

DELPhw 2.

~~z m

9,n 3.

smc_D

~

4, CAP l

s.

-w ze, w. s. L l

i 5

3 l

t' /1 y f

,,\\

-k-f - - -

/

\\

//N i

- V,/

\\

v-s

/

//

x f </

x

/

x 4

~

/ so< /'

/

A N'

\\,y a

l,l y,

1

\\

[/

u[\\-

\\

N 4

i s

~

\\

1/

~Q mm s

s TELL TA E 65 M5E rnb \\[

Scelt a:l i

PAGE1 NRC FORM 567 U. S. NUCLEAR RE;ULATORY COMMISSION um p

j REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION j

INSTRUCTIONS: Sen.1 this request AND a copy of all related letters / applications and drawings to: The Sealed Source Safety Section, ATT OWFN Mall Stop 6 H3. Change the Ucense Tracidng System milestone to 19 and assign to reviewer code 14.

i NOTE: Retain a copy of this request with the application and background files.

REQUESTER' REGION /LOCATlON:

M li 11 111 IV V

HQ R LFDCB s

l TELEPHONE NUMBER DATE TYPE OF ACTION REQUESTED (Check as appropriate) i APPUCANTS NAME SOURCE REVIEW AMENDMENT OF OMh7 c/C//J /

d. Sin (

REGISTRATION SHEET MAL CONTROL NUMBER (S)

DEVICE REVIEW N B S)

/07_

LmudAPPUCATION TE UCENSE NUMBER (S)

CUSTOM REVIEW Mb8N M

  1. A~O b

ll a2l

~~":

p Ai no nu E. 4vE.

fu/.sai oK 9M j

FOR SSSS USE ONLY n

b NPS C&lidet eemM/

b' '

% -HL REVIEWER MODEL NUMBERS g/g NUMBER ASSIGNED i

DATE RECENED DATE ASSIGNED

/

DATE TO FEES

//

/

FM

//

7 b

i TYPE OF ACTION /(indicate % number of each type)

(

l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM)

SOURCE (9C)

DEVICE (9A)

SOURCE (90)

DEVICE (9B)

NEW NEW NEW NEW j

AMENDMENT d MENDMENT AMENDMENT AMENDMENT i

{

go SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED 1

) OTHER (Spedty) 4 TOTAL NUMBER OF NOTES i

REVIEW HOURS

44. >

NUMBER OF DEFICIENCY LETTERS NUMBER OF DEFICIENCY CALLS FOR BILLING PURPOSES ONLY NAME CHANGE ADDRESS CHANGE NEW REGSTRATION -

] PRODUCT INACTE -

ADD TO BILLING REMOVE FROM BILLING FOR FEE USE ONLY TYPE OF FEE FEE CATEGORY b

)

]9A 98 9C 9D e

AMOUNT RE CHECK NUMBER MATANN UPDATED

[

_ j n

- AS REQUIRED

,g DATE OF g LOG f f JW _j TSYS PDATED APPROVED BY

/ h l

DATE RETURN DATE g

4f) -

l T/ 3//

COMutNTS

[

t NRC FORM 567 (843)

@ lOl N g,

t