ML20137C142
| ML20137C142 | |
| Person / Time | |
|---|---|
| Site: | 07109143 |
| Issue date: | 01/13/1986 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML20137C133 | List: |
| References | |
| NUDOCS 8601160210 | |
| Download: ML20137C142 (3) | |
Text
.._______________________________________ h &_ _ ____---_5 I
I U.S. NUCLEAR REGULATORY COMMISSION Mac cones sis CERTIFICATE CF CHMPLIANCE I
I
==> -
I o CrR 7' FOR RADIOACTIVE MATERIALS PACKAGES I
I i.aCERTIFICATE NUMBER b.REVLSION NUM8ER
- c. PACKAGE IDENTIFICA flON NUMBER d PAGE NUMBER
- e. TOTAL NUMBER PAGES I
9143 2
tlSA/9143/B(ll) 1 2
I I
I
- eREAMetE I
- a. This certifecate is issued to certify that the packagmg and contents described en item 5 below, rneets the applicable safety standards set forth in Title 10. Code l
g of Federai Regulations. Part 71," Packaging and Transportation of Radioactive Material" N
i I
- b. Tnis certificate does noi rei. eve the consignor from compiiance with any requirement of the reguistions of the u.s. Department of Transportation or other I
applicable regulatory agencies, includmg the government of any country through or into which the package will be transported.
I I
i I
i i
l 3 THIS CERTIFDCATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSa$ REPORT OF THE PACKAGE DESIGN OR APPLICATION l
I
- e. ISSUED TO (Afame aner AMess#
te TITLE AND 40ENTIFICATION OF REPORT OR APPLICAT60N I
I l
Tech / Ops RPG, Inc.
Technical Operations, Inc. application dated l
l 40 North Avenue August 1,1980.
I I
Burlington, MA 01803 i
i i
71-9143 p
- c. DOCxET NUMeER a CONDITIOHS I
This certificate is conditional upon fulfalling the requirements of 10 CFR Part 71, as applicable, and the cond4tions specified below.
I I
i l
s N
N H
I g
(a) Packaging g
i E
I (1) Model No.:
920 W
l N
l (2) Description l
l N
I A stainless steel encased, uraniun shielded radiograohic device. The
)
I shipping container is 13.0 inches long, 7.7 inches high and 5.3 inches l
I wide. The radioactive source assembly-is housed inside.a tungsten l
l source tube.
The source tube is surrounded by depleted uranium metal I
I for shielding.
The depleted uranium shield assembly is" encased in a stainless steel housing. The void space between the uraniun shield I
assembly and stainless steel housing.is-filled with a castable rigid y
q polyurethane foam. The gross weight of the container is 47.0 pounds.
E I
E I
(3) Drawings g
I The packaging is constructed-in accordance with the following Technical I
Operations, Inc. Drawing Hos. 92090, Sheets 1, 2, and 3 of 3, Rev. 0;
[.
q 90090, Sheets 3, and 4 of 4, Rev. 0; and 90091, Sheet 1 of 1, Rev. A.
E l
l E,
I l
E6 l l 6
i n
l l
l l
i i
l l
i i
I B601160210 860113 l
l PDR ADOCK 071 3
i I
C l
l N
l l
l l l
ymmmmmmm--------
A4mmmmAmmmmm-------mmmmmmmmmmmmmmmmmmm9
(
ll I
l CONOSTl:NS (continucd) i N
l Page 2 - Certificate No. 9143 - Revision No. 2 - Docket No. 71-9143 l
N I
W X
H l
l S.
(b) Contents l
(1) Type and fom of material h.
s W
H Iridiun 192 as sealed sources which neet the requirements of special N
4 fom radioactive material.
E; A
R l
(2) flaxinue quantity of naterial per package a
s 240 curies
'i s
)
6.
The source shall be secured in the shielded position of the packaging hy the l
source assembly.
The source assembly must be fabricated of naterials capable of g
resisting a 1475 F fire environment for one-half hour and maintaining their g
g positioning function.
The source assembly must engage the locking device. The g
source assembly must be of sufficient length and diameter to provide oositive positionina of the source within the depleted uranium shield assembly.
4 j
I 7.
The name plate shall be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining their legibility.
l 8.
The package authorized by this certificate is hereby approved for use under the 9
general license provisions of 10 CFR 571.12.
i 9.
Exoiration date: Janua ry 31, 1991.
f d
REFERENCE A
f Technical Operations, Inc. application dated August 1,1980.
M!
lN ql FOR THE l'.S.
NUCLEAR REGl!LATORY C0f tl1ISSION lSl i
Charles E. flacDonald, Chief l
Transportation Certification Branch l
Division of Fuel Cycle and flaterial Safety, fP1SS l
Date:
JAN 131986 n
i 8
l4 N
N i
N N
i E
R W
l l
s b
I N
i I.
3 y y,s 3,........
.g,.
s; UNITED STATES NUCLEAR REGULATORY COMMISSION 3
o t
j WASHINGTON, D. C. 20555
%...../
Transportation Certification Branch Approval Record Model No. 920 Packagina Docket No. 71-9143 By application dated Moveriber 26,1985, Tech /00s RPD, Incorporated requested renewal of Certificate of Compliance No. 9143. No chances have been reouested or made to the package since aporoval of Technical Operations' application da ted August 1,1980.
The staff concludes that the statenents of the original aonlication dated August 1,1980, satisfy the requirement for renewal of the certificate of compliance.
Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NFSS Date:
JANI 3 SE l
.,