ML20137C064

From kanterella
Jump to navigation Jump to search
Forwards LER 97-002 Documenting Failure of HPCI Pump Discharge Valve to Open Upon Manual Demand Signal,During SD Conditions.Util Commitment Is to Evaluate SR & Balance of Plant Valves from Overall Plant Risk Perspective
Date released: 05/30/2020 Download: ML20137C064


:on 970216,HPCI Sys Pump Discharge Valve Failed to Open.Caused by Failure of Pinion Gear Setscrew.Maint Procedure Controlling Work on Valve Mos Revised,Motor Shaft for Valve E4150-F006,spot Drilled & New Setscrew Installed
ML20137C075
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 03/18/1997
From: Wittschen R
DETROIT EDISON CO.
To:
References
Download: ML20137C075 (4)
Forwards LER 97-002 Documenting Failure of HPCI Pump Discharge Valve to Open Upon Manual Demand Signal,During SD Conditions.Util Commitment Is to Evaluate SR & Balance of Plant Valves from Overall Plant Risk Perspective
ML20137C060
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 03/18/1997
From: Gipson D
DETROIT EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
CON-NRC-97-0024, CON-NRC-97-24
Download: ML20137C060 (1)