_-.
l%
A QS g.gg f
1
+
L JAN 101986 ji Dr. Andre Schmitt-Assistant au Directeur de la Surete Nucleaire
[
Charge de Relations Internationales Commissariat a l'Energie Atomique i
l ISPN, DAS' CEN/FAR - B.P._No. 6 F - 92260 Fontenay-aux-Roses 4
France i
j
Dear Dr. Schmitt:
I i
Dr. B. 'Mohamadioun of the CEA staff,'his consultants, Dr. M. Bouchon and Mr..
i A. Pecker, and Mr. L. Beratan, and Dr. A. Murphy of the NRC staff and their contractor, Dr. R. Archuleta,.recently visited Mammoth Lakes, California,'to i
examine the ongoing experiment to measure down-hole propagation of seismic strong ground motion. The soil cover at Mammoth Lakes is a glacial-till.
Because this soil cover is so non-typical.of alluvial soils, another site in r
alluvial soil underlain by crystalline rock in.a seismically active-ared was 3
sought. The area agreed upon for a second down-hole experiment was Anza, California, near the San Jacinto fault which is seismically very active. ~The 4
general area for the experiment has been identified, but the specific location j-with the required approvals for access.have not yet been obtained.
i i
It is proposed that two large diameter holes (6 or 7 inches) will be drilled, one to the top of the rock and one to a depth of 150 to 200 meters, the final' depth to be determined on site by Dr. Archuleta. A soil boring will be made so that an accurate profile can be determined.. Soil sampling will be made by the i.
use of a 2 inch split spoon sampler. driven by a 140 pound weight having a free i
fall of 30 inches. Samples will be taken.every 10 feet'or change in soil formation. Samples taken from the. sampler will be sealed in jars for later y
analysis at the Corps of Engineers Waterways Experiment Station-in Vicksburg, 3
Mississippi. Three undisturbed Shelby tube samples will be obtained from each of three soil horizons for dynamic testing (nine Shelby tube samples). See i
enclosure for a testing program and costs..This experimental work is.
3 considered essential to the true understanding of the wave. propagation from rock through the alluvial soil overburden. This type of experiment has not-j been conducted elsewhere to our knowledge and should provide data to validate l
presently used' soil structure interaction models.
1 1
In accordance with the letter-of-understanding signed by Mr. R.B. Minogue, l
l Director, Office of Puclear Regulatory Research, USNRC, on July 8. 1985, and-i i
t I
0FC: DRPES/ESB
- RES
- DRPES/D-8601160060 e60110 i
NAME:LBeratan/mb :JCsrtez
- KRGoller 8600160060 PDR
_____.........__.._____________________a....___________.
1 l-DATE:1/ /86
- 1/ /86
- 1/' /86 i
4
--__--._.-_A.-..-_.,__
...,...,-.-.,....c.
,-,s
e y
JAN 101986
.l i
i
_2.
Dr. F. Cogne, Directeur, de l'Institut de Protection et de Surete Nucleaire, on August 20, 1985,;the NRC would agree to pay for the instruments to be installed in the bore holes and their installation.and the maintenance of.the program for three years. The estimated cost to the NRC will be $60,000/ year over three i
years for a total cost of $180,000..The estimated cost to the CEA for borings, i
sampling, logging, soil testing, transportation and handling is estimated to be
$69,600 U.S. dollars (see enclosure for detailed estimate). Copies of all data from the experiment and testing will be given to the CEA for analysis by its I
experts. A copy of all analyses perfonned on the data.by the CEA and its l
experts will be furnished to the NRC.
If this is agreeable to you, please indicate by your signature below and return l
a copy to me. Work on this cooperative agreement can begin immediately there 6
after.
(
i Sincerely, Orfsinaf sienM by i
l KsrlIL G0!!er l
Karl R. Goller, Director
{
Division of Radiation Programs &
j Earth Sciences t
Office of Nuclear Regulatory Research l
I l
Enclosure:
j i
Activities and Estimated Cost.to be t
l Funded by CEA 1
i cc: w/ encl i
J. Cortez, RES i
R. Hauber, IP i
B. Mohammadioun, CEA
[
t i
t i
j I agree to the cooperative agreement described above under the conditions i
indicated:
i t
I i
i I
lDr.AndreSchmitt Date i
j.
Assistant au Directeur de la Surete Nucleaire Charge de Relations Internationales 1
i Distribution /R-2811:
i Circ /Chron RMinogue Econti-i D /PDR Dross LBeratan-j ESB S Rd KGoller AMurphy j
'JCort j
i
___.b..........[_
i f_
NAME:LBeratan/mb :JC~
- KRGoller j
DATE:1//D/86 1/
86
- 1//a /86
- ~
Activities and Estimate of Costs to be Funded by CEA One boring to 200 meters (through soil and rock) hole to be cased to rock; One boring to the bottom of the soil sediments hole to be cased.
$34,000 One soil boring for soil testing program. Recover 9 undisturbed Shelby tube samples, standard split spoon samples every 10 feet or changes in soil formation and logging of the hole by a soil engineer.
$12,000 Cross hole shear wave velocity measurements.
$ 8,000 Soil testing:
$10,600 6 Drained triaxial shear tests 3 Resonant column tests 3 Grain size analyses 3 Liquid limit tests 3 In situ dry density tests 3 Minimum-maximum density tests 47 Moisture content tests Shipping and packing (California to WES, COE) and shipping of samples to laboratory for resonant column tests.
$ 4,000 Receiving and handling at WES, COE.
$ 1,000 TOTAL
$69,600 JAN 10 1986 L