Text
-
l QEEEeIING_DeIe_EEEQEI DOCKET NO. 50-282 UNIT PRAIRIE ISLAND N0.1 DATE OCTOBER 4, 1985 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121 OEEEeIING_SIeIUS 1.' UNIT NAME:
EBeIBIE_ISLeUD_HQ._1
- 2. REPORTING PERIOD:__SEEIEMBEB_1285___
l NOTES : 11/04/85 1
l Corrected gross thenmall
- 3. LICENSED THERMAL POWER (MWT):
1650 I
g
- 4. NAMEPLATE RATING (GROSS MWE):
593
- 5. DESIGN ELECTRICAL RATING (NET MWE):
530 i energr generated values 4
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 534 l
l
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):
503 1____________________1 8.
IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)
SINCE LAST REPORT GIVE REASON:
_HQNE______________________________
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)-
_dQUE______________
- 10. REASONS FOR RESTRICTIONS, IF ANY:__NQUE_______________________________
ISIS _dQUIH YE:IO:DeIE CUduLGIIVE
- 11. HOURS IN REPORTING PERIOD 720 655i 103367
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL 716.1 5154.2 85148.5
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 5571.1
- 14. HOURS GENERATOR ON-LINE 705.8 5125.6 83793.4
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 1156272 8161574 131760832
- 17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 386100 2688590 42980690
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 362479 2520190 40271008
- 19. UNIT SERVICE FACTOR 98.0 78.2 81.1
- 20. UNIT AVAILABILITY FACTOR 98.0 78.2 81.1
- 21. UNIT CAPACITY FACTOR-(USING MDC NET) 100.1 76.5 77.5
- 22. UNIT CAPACITY FACTOR (USING DER NET) 95.0 72.6 73.5
- 23. UNIT FORCED OUTAGE RATE 2.0 0.8 7.8
- 24. FORCED OUTAGE HOURS 14.2 43.6 7088.0
- 25. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE & DURATION OF EACH):
_____SEEUELING_QUIeGE_IH_deECB__io86.__________________________________
l
- 26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATE:_________Nie______________
l 8601000695 851107 gDR ADOCK 05000282 PDR l
l l
l
UNII_SBUIDOWNS_eUD_EQWER_BEDbCIIQB DOCKET NO 50-282 UNIT NAME EEeIBIE_ISLeUD_NQ.1 D ATE October 4, 1985.____
COMPLETED BY DELE _DUGSIeD TELLEPHONE 612_388_1121 NOTE:
corrected reporting period.
d Q tfIU;._sagtember___ _1E 85_ _ _ __
DeIE IYEE HOUBS EEeSON MEIUDD LER_UUdBES SYSIEd CQdEQUENI YY/MM/DD 000.0 85/09/15 F
14.2 A
3 85-012 EL XXXXXX THE UNIT TRIPPED ON GENERATOR LOSS OF EXCITATION.
85/09/15 S
0.0 B
9 N/A N/A TURBIN TURBINE OVERSPEED TRIP TEST.
IYEE BEeSQU dEIBOD SYSIEd_ CODE F-FORCED A-EQUIPMENT FAILURE i-MANUAL DRAFT IEEE STD S-SCHED B-MAINTENANCE OR TEST 2-MANUAL TRIP 805-1984(P805-D5)
C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING &
5-REDUCED LOAD C0dEONENI_ CODE LICENSE EXAMINATION 9-0THER F-ADMINISTRATIVE IEEE STD 803A-1983 G-OPERATOR ERROR H-0THER
.. v~
UNII_SUUIDOWUS_GUD_EDWE8_BEDUCIIQB DOCKET NO 50-AQ6 UNIT NAME EEeIBIE_ISLedD_NO 2 DATE October 4,1985 COMPLETED BY DELE _DUGSIeD TELLEPHONE 612_388_1121 NOTE: Corrected reporting period.
dQUIBl_ optedwx___1285_____
DeIE IXEE HOURS BEeSON dEIUDD LE8_UUdBE8 IXSIEd CQdEONENI YY/MM/DD 000.0 85/09/06 S
599.9 C
i N/A RC FUELXX THE UNIT WAS TAKEN OFF-LINE FOR TEN YEAR ISI AND REFUELING OUTAGE.
85/09/06 S
0.0 B
5 N/A N/A TURBIN TURBINE OVERSPEED TRIP TEST.
IXEE BEeSON dEIUDD SXSIEd_ CODE F-FORCED A-EQUIPMENT FAILURE i-MANUAL DRAFT IEEE STD S-SCHED B-MAINTENANCE OR TEST 2-MANUAL TRIP 805-1984(P805-D5)
C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING &
5-REDUCED LOAD COMEQUEMI_ CODE LICENSE EXAMINATION 9-0THER F-ADMINISTRATIVE IEEE STD 803A-1983 G-OPERATOR ERROR H-0THER t
,