r-
]
I t itliitH ulu tallii l dns en (.olup.ui)
/i8 H1 ( et'titT.Aling %I.al H un lui sinloh lhiult s. int
/it all. II. 64 H PPJ ft;*
'liisi : eu.cox February 11, 1997 Mr. A.
B. Beach Regional Administrator Region III U.S.
Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351
Subject:
Zion Station Operating Report NRC Dockets 50-295 and 50-304 Dear Mr. Leach Enclosed are the 1996 Occupational Radiation Exposures for Zion Nuclear Power Station in accordance with NRC Reg. Guide 1.16.
Sincerely yours, v
/
77 ICCc W.,S. Lacey, Station dag i
Zion S io WSL/dem cc:
NRC' Document Control: Desk NRC' Resident Inspec' tor NRC Office of Research Regulatory Assurance, Zion f
Master File J ' {[ t] h
' (
9703180003 961231 PDR ADOCK 05000295 R
PDR h:\\nrcregl.16 1700GG RI[lppsppijilpEpp
\\ l 'nio nn (.omp.in)
. _.. ~ ~.
.-.. - ~. - ~ - - -
--.~~ - -~ ~~- -.~ ~-
e 4
e REGULATORY GUIDE 1.16 REPORT r
f NUMBER OF PERSONNEL AND PERSON. REM BY WORK AND JOB FUNCTION FOR 1996
......... NUMBER OF PERSONNEL.......
....- QUANTITY OF PERSON. REM STATION CONTRACTORS / ITI!LITY TOTAL STATION CONTRACTORS / LTTILITY TOTAL WORK AND JOB FUNCTION EMPI4YEES OTHERS EMPLOYEES PFRSONS EMPLOYEES OTHERS EMPLOYEES PERSON. REM 4.....
REACTOR OPERATIONS AND SURVEILLANCE ENGINEERING 1
1 0
0.051 0,026 0.000 HEALTH PHYSICS 0
0 0
0.000 0.000 0.000 MAINTENANCE -
0 0
0 0.043 0.053 0.000 OPERATIONS 98 0
0 12.227 0.000 0.000 SUPERVISORY 30 0
0 1.635 0.009 0.000 129 2
0 131 13.956 0.088 0.000 14.043 ROITTINE MAINTENANCE ENGINEERING 144 45 0
5.851 0.880 0.000 HEALTH PHYSICS 60 76 63 17.026 21.851 1.055 MAINTENANCE 142 999 15 42.924 255.534 1.274 OPERATIONS 29 182 0
3.610 0.560 0.000 SUPERVISORY 168 149 0
9.041 6.299 0.000 543 1451 78 2071 78.452 285.124 2.329 365.904 INSERVICE INSPECTION ENGINEERING 1
19 0
0.040 0.367 0.000 HEALTH PHYSICS 0
0 12 0.014 0.003 0.208 MAINTENANCE O
111 0
0.041 28.326 0.000 SUPERVIFORY 0
28 0
0.008 1,169 0.000 i
157 12 171 0.104 29.865 0.208 30.176 SPECIAL MAINTENANCE MAINTENANCE O
4 0
0.000 1.142 0.000 SUPERVISORY 0
117 0
0.000 4.972 0.000 0
122 0
122 0.000 6.P4 0.000 6.114 REFUELING ENGINEERING 4
1 0
0.168 J.010 0.000 HEALTH PHYSICS 0
0 14 0.090 0.132 0.235 MAIFTENANCE 29 4
1 8.718 1.046 0.088 OPERATIONS 22 0
0 2.763 0.000 0.000 SUPERVISORY -
26 1
0 1.398 0.039 0.000 81 6
15 102 13.137 1.227 0.323 14.687 WASTE PROCESSING l
ENGINEERING 0
0 0
0.004 0.000 0.000 HEALTH PHYSICS 3
4 0
0.776 1.026 0.003
- MAINTENANCE 1
6 0
0.395 1.525 0.000
' OPERATIONS 12 0
0 1.553 0.000 0.000 SUPERVISORY 9
0 0
0.473 0.000 0.000 25 10 0
35 3.200 2.551 0.003 5.754 l
e.
1
\\
l l
l REGULATORY GUIDE 1.16 REPORT
+
l NUMBER OF PERSONNEL AND PERSON. REM BY WORK AND JOB FUNCTION FOR 1996 l
........ NUMBER OF PERSONNEL. -....
..... QUANTITY OF PERSON. REM -.-.
STATION CONTRACTORS / (TTILITY TOTAL STATION CONTRACTORS / LTTILITY TOTAL WORK AND JOB FUNCTION EMPLOYEES OTi(ERS EMPLOYEES PERSONS EMPLOYEES OTHERS EMPLOYEES PERSON. REM TOTAL BY JOB FUNCTION l
ENGINEERING 15e 65 0
215 6.113 1.284 0.000 7.397 i
HEALTH PHYSICS 63 80 89 232 17.906 23.011 1.501 42.418 MAI!frENANCE 173 1125 16 1314 52.122 287.626 1.362 341.110 OPERATING 161 182 0
343 20.152 0.560 0.000 20.712 SUPERVISORY 233 295 0
528 12.555 12.487 0.000 25.042
- *
- GRAND TOTAL "
- 780 1747 105 2632 108.848 324.968 2.863 436 679 i
r l
I t
l i
l