Text
.
L Westinghouse Energy Systems sa 355 Electric Corporation Pittsburgh PennsyNania 15230-0355 NSD-NRC-97-5014 DCP/NRC0764 Docket No.: STN-52-003 March 10,1997 Document Control Desk U.S. Nuclear Regulatory Conunission Washington, DC 20555 ATTENTION:
T.R. QUAY
SUBJECT:
WCOBRA/ TRAC Long Term Cooling Letter Report
Dear Mr. Quay:
As a result of discussions with the NRC on the " windows mode" approach used in the WCOBRA/ TRAC Long-Term Cooling Validation Report (WCAP-14776), Westinghouse has performed additional calculations for window times a factor of three longer. A brief sununary of the results is contained in the letter report provided as Enclosure 1. The results demonstrate that divergence does not occur when WCOBRA/ TRAC is run for extended times. The information contained in the attached document will be discussed at the March 28,1997, ACRS Thermal Hydraulic Subcommittee meeting on Long Term Cooling.
Enclosure I contains Westinghouse Proprietary information.
-l is a nonproprietary version of Enclosure 1.
'Ihe Westinghouse Electric Corporation copyright notice, proprietary information notice, application for withholding and affidavit are attached.
This submittal contains Westinghouse proprietary information consisting of trade secrets, conunercial information or financial information which we consider privileged or confidential pursuant to 10CFR2.790. Therefore, it is requested that the Westinghouse proprietary information attached hereto be handled on a confidential basis and be withheld from public disclosures. A non-proprietary copy of
. the enclosed report will be provided within 60 days of this letter.
This material is for your internal use only and may be used for the purpose for which it is submitted.
It should not be otherwise used, disclosed, duplicated, or disseminated, in whole or in part, to any other person or organization outside the Commission, the Office of Nuclear Reactor Regulation, the Office of Nuclear Regulatory Research and the necessary subcontractors that have signed a proprietary non-disclosure agreement with Westinghouse without the express written approval of Westinghouse.
PDR ADOCK 05200003
)vp, p.d 9703170257 970310
\\
A PDR~
I ffb( & sW, Y L
i
- ppmams
e O
1 i,
t, g
NSD-NRC-96-5014 DCP/NRC0764 March 10,1997 Correspondence with respect to the application for withholding should reference AW-97-1086, and should be addressed to B. A. McIntyre, Manager of Advanced Plant Safety and Licensing, Westinghouse Electric Corporation P.O. Box 355, Pittsburgh, Pennsylvania, 15230-0355.
Please contact Brian A. McIntyre at (412) 374-4334 if you have any questions concerning this transmittal.
.A.
B. A. McIntyre, at ger Advanced Plant Safety and Licensing i
jml Enclosures ec:
W. Iluffman, NRC (Enclosures 1 & 2)
L. Lois, NRC (Enclosure 1)
P. Boehnart, ACRS (Enclosure 1)
Dr. Ivan Catton, (Enclosure 1)
Dr. Vijay Dhir, (Enclosure 1)
Dr. Thomas S. Kress, ACRS (Enclosure 1)
Dr. Mario 11. Fontana, ACRS (Enclosure 1)
Dr. Robert L. Seale, ACRS (Enclosure 1)
Dr. Virgil Schrock, (Enclosure 1)
Dr. Novak Zuber, (Enclosure 1)
N. J. Liparuto, Westinghouse (w/o Enclosures) 3111 A
O
^
o-COPYRIGHT NOTICE The reports transtnitted herewith each bear a Westinghouse copyright notice. The NRC is permitted to make the number of ropies of the information contained in these reports which are necessary for it!.
internal use in connection with generic and plant-specific reviews and approvals as well as the iscuance, denial, amendment, transfer, renewal, modification, suspension, revocation, or violation of a license, permit, order, or regulation subject ~ k r~.luirement: of 10 CFR 2.790 regarding restrictions on public disclosure to the extent such information has been identified as proprietary by Westinghouse, copyright protection notwithstanding. With respect to the non-proprietary versions of these reports, the NRC is permitted to make the number of copies beyond those necessary for its internal use which are necessary in order to have one copy available for public viewing in the appropriate docket files in the public document room in Washington, D.C. and in local public document rooms as may be required by NRC regulations if the number of copies submitted is insufficient for this purpose. Copies made by the NRC must include the copyright notice in all
' instances and the proprietary notice if the original was identified as prcprietary.
m L___
~
o 1 '
i PROPRIETARY INFORMATION NOTICE l
Trartmitted herewith are proprietary and/or non-proprietary versions of documents furnished to the NRC in connection with requests for generic and/or plant specific review and approva!
4 In order to conform to the requirements of 10 CFR 2.790 of the Commission's regulations concerning the protection of proprietary information so submitted to the NRC, the information which is j
proprietary in the proprietary versions is contained within brackets, and where the proprietary
~
j mformation has been deleted in the non-proprietary versions, only the brackets remain (the it. formation that was contained within th( brackets in the proprietary versions having been deleted).
The jusm%uon for claiming the infornu tion so designated as proprietary is indicated in both versions by ne ans of lower case letters (a) throush (f) contained within parentheses located as a superscript w.ucastely following the brackets enclosing each item of information being identified as proprietary j-or in t'e margin opposite such information. These lower case letters refer to the types of information j
W aghause customarily holds in confidence identified in Section (4)(ii)(a) through (4)(ii)(f) of the i
Dvit accompanying this transmittal pursuant to 10 CFR2.790(b)(1).
)
s i
1 i
4 l
1' 0330A