Revises Relief Request ISI-017,rev 1,App 2 to Read as Listed Re Authorization Requested Per 10CFR50.55a(a)(3)(ii)
ML20136F226
Person / Time
Site: Waterford Entergy icon.png
Issue date: 03/11/1997
From: Gaudet T
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
W3F1-97-0040, W3F1-97-40, NUDOCS 9703140039
Download: ML20136F226 (2)


Text

--

  • ~S

= Entergy l"2""*"* '"'

Operations gg =

f W3F1-97-0040 l

A4.05 PR March 11,1997 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 Inservice inspection (ISI) Relief Request 1S1-017, Revision 1, Request Authorization to Substitute Visual (VT-3) Examination for the Code-required Surface or Volumetric Examination of the four Reactor Pressure Vessel Support integral Attachment Welds (ISI Exam Number 01-074)

Gentlemen:

l On February 21,1997, during a conference call between NRR, INEL and Waterford 3 personnel, questions were raised regarding the alternative examination proposed j

in Inservice Inspection Relief Request 1S1-017, revision 1. In letter W3F1-97-0014 dated February 13,1997, Waterford 3 requested authorization to perform a visual (VT-3) examination in lieu of the Code-required surface or volumetric examination of the Reactor Pressure Vessel Support Integral Attachment Welds.

During the call, INEL raised questions about using a VT-3 examination in lieu of a surface or volumetric examination. The ensuing discussion addressed the type of loading the Reactor Pressure Vessel Support Integral Attachment Welds would be subjected to, the type degradation that could occur and the method of examination that would best detect this degradation.

The feasibility of performing a VT-1 examination of the welds was also addressed.

The anticipated dose rates and inaccessibility to portions of the weld were discussed at length. Recognizing that only a partial examination would be feasible, INEL and h

NRR recommended a partial VT-1 in conjunction with the requested VT-3 be

,N.f tl '

I considered in lieu of the Code-required surface or volumetric examination.

fl 9703140039 970311 I

i' DR ADOCK 0500 2

ggg g

i

1

.a Request to Substitute Visual (VT-3) Examination for Surface or Volumetric Examination of the four Reactor Pressure Vessel Support Integral Attachment Welds (Relief Request ISI-017)

W3F1-97-0040 Page 2 March 11,1997 Waterford 3 is therefore revising the " Relief Requested" portion of Relief Request ISI-017, Revision 1, Appendix 2 to read as follows:

l Authorization is requested pursuant to 10CFR50.55a(a)(3)(ii) to substitute a visual (VT-3) examination for the Code-required surface or volumetric examination of the four RPV support integral attachment welds, supplemented with a VT-1 of accessible areas.

in addition, the " Alternate Testing" portion of this relief request is revised as follows:

Perform a VT-3 visual examination on the subject inlet nozzle support pad welds, supplemented with a VT-1 visual examination of the accessible areas.

Waterford 3 respectfully requests a timely review of this Relief Request to allow for appropriate planning of Refuel 8 ISI inspection activities, currently scheduled for April,1997. A copy of this letter is also being sent to INEL, the NRC's contractor to facilitate the review.

Should you have any questions regarding this matter, please contact me at (504) 739-6666.-

Very truly yours,-

6 r

T. J. Gaudet Acting Director Nuclear Safety & Regulatory Affairs TJG/DMU/tjs cc:

L. J. Callan, NRC Region IV C.P. Patel, NRC-NRR R.B. McGehee N.S. Reynolds NRC Resident inspectors Office M. T. Anderson, INEL Research Center

-