Responds to FOIA Request for Last Two NRC Insp Repts for St James Hosp in Chicago Heights,Il.Documents Listed on Encl App Available in PDR
Date released: 05/30/2020 Download: ML20136D927


Insp Findings & Licensee Ack on 830819 of License 12-11483-01.Insp Findings:Failure to Amend License to Reflect Mods to Xe-133 Ventilation Sys & Resulting Airflow Rates,Per License Condition 19
ML20137A353
Person / Time
Issue date: 08/19/1983
From: Shatterly L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
References
FOIA-85-524
Download: ML20137A353 (15)
Responds to FOIA Request for Last Two NRC Insp Repts for St James Hosp in Chicago Heights,Il.Documents Listed on Encl App Available in PDR
ML20137A156
Person / Time
Issue date: 08/06/1985
From: Felton J
NRC OFFICE OF ADMINISTRATION (ADM)
To: ONDRIK J
NUCLEAR PHARMACY, INC.
References
FOIA-85-524
Download: ML20137A156 (2)
Informs That Ir-192 Sources Held Until Return to Supplier. Any Unused Ir-192 in Future Will Be Inventoried in Quarterly Physical Inventory.All Patients w/I-125 Seed Implants Now Receive Encl Instruction in Retrieval of Dislodged Seeds
ML20136D956
Person / Time
Issue date: 10/30/1980
From: Sherry Liu
ST. JAMES HOSP., CHICAGO HEIGHTS, IL
To: DAVIS A B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
FOIA-85-524
Download: ML20136D956 (2)
Requests Amend to License 12-11483-01 Authorizing Increased Use of Technetium from 3,000 Mci to 4,000 Mci.Amend Fee Encl
ML20136D952
Person / Time
Issue date: 10/02/1980
From: Sister Antoinet
ST. JAMES HOSP., CHICAGO HEIGHTS, IL
To: COOPER R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
FOIA-85-524
Download: ML20136D952 (1)
Responds to NRC 801010 Ltr Re Violations Noted in IE Insp of License 12-11483-01.Corrective Actions:Requests Increase of Authorized Use of Techetium from 3 to 4 Ci
ML20136D945
Person / Time
Issue date: 10/27/1980
From: Sister Antoinet
ST. JAMES HOSP., CHICAGO HEIGHTS, IL
To: DAVIS A B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
FOIA-85-524
Download: ML20136D945 (1)
Ack Receipt of 801027 & 30 Ltrs Informing NRC of Steps Taken to Correct Violations Noted in IE Insp of License 12-11483-01
ML20136D940
Person / Time
Issue date: 11/18/1980
From: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: SISTER ANTOINET
ST. JAMES HOSP., CHICAGO HEIGHTS, IL
References
FOIA-85-524
Download: ML20136D940 (1)
Notice of Violation from Insp on 800929 & 1001.Noncompliance Noted:Possession of More than Max Amount of Mo-99.Quarterly Physical Inventory Did Not Include Ir-192 Held in Storage. Records for Radiation Exposure Not Complete
ML20136D928
Person / Time
Issue date: 10/10/1980
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
References
FOIA-85-524
Download: ML20136D928 (15)
Discusses IE Insp of License 12-11483-01 on 800929 & 1001 & Forwards Notice of Violation.Requests Assurance That Patients Involved in I-125 Seed Implant Therapy Will Be Given Instructions Re Retrieval & Return of Dislodged Seeds
ML20136D923
Person / Time
Issue date: 10/10/1980
From: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: SISTER ANNETTE
ST. JAMES HOSP., CHICAGO HEIGHTS, IL
References
FOIA-85-524
Download: ML20136D923 (2)