Advises That No Nuclear safety-related Equipment Procured from Exo Sensors,Inc During Const or After Operation,Per Insp Rept 99901015/85-01 Determining Deficiencies in QA Program
ML20136D011
Person / Time
Site: Davis Besse 
Issue date: 12/26/1985
From: Williams J
TOLEDO EDISON CO.
To: Norelius C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
REF-QA-99901015 1-602, NUDOCS 8601060009
Download: ML20136D011 (1)


Text

_ _ _.

TOLEDO

%ms EDISON Docket No. 50-346 JOE WILUAMS, JR Senor Vom Presdent-NurJew (419]249-2300 License No. NPF-3 (4i91249 s223 Serial 1-602 December 26, 1985 Mr. Charles E. Norelius, Director Division of Reactor Projects United States Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137

Dear Mr. Norelius:

On November 26, 1985 Inspection Report (99901015/85-01) was issued for Exo Sensors Inc., of Anaheim California who is a supplier of hydrogen sensors, analyzers and other instrumentation. This inspection determined that significant deficiencies exist in the implementation of the Exo Sensors Quality Assurance Program which should have been identified during Utility Quality Assurance audits and source inspections at their facility.

Toledo Edison reviewed this report and researched our procurement records to determine the extent of activity with Exo Sensors Inc., as implied in the Inspection Report. This review has disclosed that no nuclear safety related ("Q") purchase orders have been issued to Exo Sensors Inc. for the Davis-Besse Nuclear Power Station Unit No. 1.

This was confirmed through a conversation on December 18, 1985 with Mr. F. Rudek, Exo Sensors Quality Assurance Manager, who further stated that their company was formed in 1980 and showed no records for nuclear safety related procurements with Toledo Edison Company.

Toledo Edison concludes that no nuclear safety related equipment was procured from Exo Sensors Inc. during construction or after commercial operation of Davis-Besse.

Exo Sensors Inc. is not maintained on the Toledo Edison Evaluated Vendors List as an acceptable supplier of nuclear safety related material.

8601060009 851226 gDR ADOCK 05000346 Very Truly yours, PDR y w n n/m DEC 271985 JW/JSL/amb cc: DB-1 NRC Resident Inspector i

THE TOLEDO EDISON COMPANY EDISON PLAZA 300 MADISON AVENUE TOLEDO, OHIO 43652 3

% Eo)

.