Public Se%e Electric end Gas Comexnv P.O. 0ns 66 Hencocks Bridt;pe, New Jmy 0803R Setem Nucteer Gmereting Station August 31, 1979 9

Mr. Boyce H. Grier Director of USNRC Office of Inspection and Enforcement Region 1 4 n Park Avenue King of Prussia, Pennsylvania 19406-De,ar sir RCPORTILBrA OCCURRENCE 79-56/OlP SAIJDE WO. 1 UNIT I.BR

- This letter will serve to confirm one telephone report to the Realdent NRC Inspector on August 30, 1979,.edvising of a report-mbig occurrence in accordance with Technical specification 6.9.1.a.

In response to an NRC question on Salem Unit No. 2 regarding RHR purnp NPSH during pont-LOCA recirculation mode, tests were run wMeh indicated that the RHR pump flow excaaded the design runout ttow.

Salem Unit No. I has an identical configuration end, therefore, a reportable condition exists.

A detai. led report will be submitted in the tJme period specified by the Technical Specifications.

very truly yours, y

c n_,

u. J. Midura Manager - Salem Generating Stntion AWKrlda cc Ganeral Manager - Electric Production Mc. nager - Quality Annurance

~

RIGNOUDacs grggpy g of g

\\

l e

m C7909190Mg

.