ML20136A626

From kanterella
Jump to navigation Jump to search
Insp Findings & Licensee Ack on 850904-05 of General License.Insp Findings:Leak/Shutter Tests Not Performed at Proper Frequency & Records Not Maintained
ML20136A626
Person / Time
Issue date: 11/01/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
References
NUDOCS 8511190568
Download: ML20136A626 (1)


Text

_____ _

NRC Form 591 U.S. NUCLEAR REGULATORY COMMISSION (12 81) 1 CF R 2.2oi SAFETY INSPECTION g gg

1. LICE NSE E
2. REGION A L OF FICE Woodlawn Canners Incorporated U.S. NUCLEAR REGULATORY C0!HISSION 1292 Glendale /Milford Rd.

REGION III Cincinnati, OH 45215 799 ROOSEVELT ROAD GLEN ELLYN. IL 60137

3. DOCKET NUMBER!S)
4. LICENSE NUMBER (S)
5. DATE OF INSPECTION 99990003 General Sept. 4,1985 - Sept. 5,1985 Licensee:

The inspection was an examination of the activities conducted under your license as they relate to rad 6atson safety and to compliance with the Nuclear Regulatory Commissions (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and rtpresentative records, interviews, with personnel, and obsetvations by the inspector. The findings as a result of this inspection are as f ollows:

] 1. Ethin the scope of this inspection, no violations were observed.

] 2. The inspector afso verified the steps you have taken to correct the violations identified during'the last inspection. We have no further questions on those actions at this time.

3.'During this inspection certain of your activities, as checked below, were in violation of NRC requirements.

THIS IS A NOTICE OF VIOLATION which is required to be posted in accordance with 10 CFR 19.11.

A.

was not properly posted to indicate the presence of a

,10 CFR 20.2031b),(c),(d), (e) or 34.42.

8. Containers located in were not property labeled to indicate the presence of radioactive material.10 CFR 20.203(f)(1), or (f)(2).

C.

of sealed sources were not performed at the proper frequencies.10 CFR License Condition Number D. Records of were not property maintained.

10 CFR or License Condition Number E. Documents were not properly posted or otherwise made available.10 CFR 19.11.

F. Reports or notifications of were not made in accordar.ce with 10 CFR or License Condition Number H.I D Ak totts/ Shutter tests nOt performed at CTODer freQuenen violation of 10CFR 31.5(c)(4).

l. Receds of leat-tests /shiitter toett nnt maintained as reauired 10CFR 31.5(c)(4)

X A. Transfer of by-product "2terial nnt normitted by 10CFR 31.5f c)98)

CK 999

,,,,w a n

/

j A

A I J

l h5rsty state that within 30 days the actions described by me to the inspector will be take to e rrect e lolat' ns identif t fn'the items check ed above.

This statement of corrective actions is made in accordance with the requirements of 10 C 42.2 1. N e th er pons be submitted unless reautred by the NRC.

O N

'h $ f W W/$&uw n-/-M s

-L

- SIGNATURE L6CENSEE DATE SIGNATUR E - NRC 4NSPE CTOR DATE NOV 71985 gggp