I Consumers Power Patrick M Donnelly y

Plant Manager MKNWmAN's pmuuress Big Rock Point Nuclear Plant.10269 US-31 North. Charlevoix, MI 49720 February 24, 1997 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-155 - LICENSE DPR BIG ROCK POINT PLANT -

1996 ANNUAL REPORT - OCCUPATIONAL EXPOSURE 1

In accordance with Technical Specification 6.9.1.5, find attached the Annual Reporting documenting Occupational Exposure in 1996 sorted by work group and job function.

/

M Robert J Addy Assistant Plant Manager CC: Administrator, Region III, USNRC l

NRC Resident Inspector - Big Rock Point

//

Executive Director of Operations - USNRC

/ fn ATTACHMENT 9703040177 961231 e

PDR ADOCK 05000155 R

PDR l!U,hElkEMf0)M,$!!

A GHS ENERGYCOMPANY

i 1

i 4

i s

ATTACHMENT CONSUMERS POWER COMPANY BIG ROCK POINT PLANT DOCKET 50-155 e

i i

1996 ANNUAL REPORT OCCUPATIONAL EXPOSURE Submitted February 24, 1997 I

i t,

5 1

)

4 l

4 0

9 1 Page

o BIG ROCK POINT NUCLEAR PLANT REGULATORY GUIDE 1.16 APPENDIX A ANNUAL REPORT e

Number of Personnel (> 100 mrem)

Total Man-Rem Job Function Contract Contract work Group Station Utility

& Other Station Utility

& Other Routine Operations & Surv.

Maintenance Personnel 1

0 0

0.394 0.003 0.002 Operations Personnel 36 0

0 22.582 0.009 0.003 Health Physics Personnel 8

0 8

3.166 0.010 2.636 Supervisory Personnel 2

0 1

0.781 0.025 0.405 Engineering Personnel 1

0 0

0.801 0.067 3.117 Routine Maintenance Maintenance Personnel 25 37 7

16.138 19.383 1.820 Operations Personnel 4

0 0

0.726 0.000 0.000 Health Physics Personnel 9

0 16 3.317 0.000 5.212 Supervisory Personnel 1

3 2

0.241 0.518 1.355 Engineering Personnel 5

0 2

1.890 0.016 2.039 Inservice Inspection Maintenance Personnel 0

16 3

0.141 8.366 1.505 Operations Personnel 0

0 0

0.000 0.000 0.000 Health Physics Personnel 1

0 8

0.210 0.000 1.330 Supervisory Personnel 1

6 15 0.237 3.542 5.077 Engineering Personnel 1

0 0

0.231 0.000 0.009 Special Maintenance Maintenance Personnel 5

22 10 2.052 8.719 5.283 Operations Personnel 2

0 0

0.407 0.000 0.000 Health Physics Personnel 8

1 14 3.205 0.130 4.286 Supervisory Personnel 0

3 27 0.204 1.412 20.299 Engineering Personnel 3

2 0

0.680 0.928 0.095 Waste Processing Maintenance Personnel 0

1 3

0.302 0.251 3.731 Operations Personnel 1

0 0

0.469 0.000 0.000 Health Physics Personnel 18 2

5 14.747 0.475 1.470 Supervisory Personnel 1

0 13 0.485 0.000 14.451 Engineering Personnel 2

0 0

0.941 0.000 0.008 Refueling Maintenance Personnel 12 15 0

4.270 6.838 0.000 Operations Personnel 21 0

0 4.232 0.000 0.000 Health Physics Personnel 4

0 5

0.784 0.008 1.011 Supervisory Personnel 4

0 2

1.006 0.007 0.379 Engineering Personnel 0

0 0

0.078 0.053 0.000 TOTALS Maintenance Personnel 43 91 23 23.297 43.560 12.341

^

Operations Personnel 64 0

0 28.416 0.009 0.003 Health Physics Personnel 48 3

56 25.429 0.623 15.945 Supervisory Personnel 9

12 60 2.954 5.504 41.966 Engineering Personnel 12 2

2 4.621 1.064 2.268 GRAND TOTAL 176 108 141 84.717 50.760 72.523

.