web December E, 1996 MEMORANDUM TO: Document Control Room Desk FROM:

Michael E. Mayfield, Chief

/s/ Michael E. Mayfield Electrical, Materials, and Mechanical Engineering Branch Division of Engineering Technology, RES

SUBJECT:

STEAM GENERATOR TUBE FLAW DISTRIBUTIONS Attached is a memorandum on the above subject dated September 11,1996, from myself to Jack R. Strosnider, Chief, Materials and Chemical Engineering Branch, DE/NRR, which transmitted a summary report from Dominion Engineering, Inc., entitled " Flaw Distributions for Example Plants". Please place the memorandum and report in the,PDR.'

Attachment:

As stated Distribution:

EMMEB Reading File J. strosnider, NRR w/o attachment J. Donoghue, NRR w/o attachment T. Reed, NRR w/o attachment DOCUMENT NAME: G:\\MEB\\MusCARA\\sTEAMGEN.PDR To receive o copy of this document, indicate in the box: "C" - Copy without attachment / enclosure "E" = Copy with attachment / enclosure "N" = No copy OFFICE EMMElf(j) lC SC/EMMEB

/] A/

C/EMMEB (l, EE l

l NAME @

J. MU$ ARA E. HACKETT / J'd (F M. MAYFIELO!\\ MY DATE /Sid 12/ l/l /96 12/ // /96 12/ 4 /9("

OFFICIAL HECORD COPY RES File Code: 1-B-9 060040 0 NE CENTER Cfpy 9612060122 961205 S

PDR ORO NREB PDR 2

c $p* **a v

't UNITED STATES j,

,j NUCLEAR REGULATOhY COMMISSION i

'C WASHINGTON, D.C. 20555-0001 o

49....,o December 5, 1996 J

\\

MEMORANDUM TO: Document Control Room Desk FROM:

Michael E. Mayfield, Chief 4

Electrical, Materials, and Mechanical Engineerin Branch Division of Engineering Technology, RES

SUBJECT:

STEAM GENERATOR TUBE FLAW DISTRIBUTIONS Attached is a memorandum on the above subject date'd September 11,1996, from myself to 'ack R. Strosnider, Chief, Materials and Chemical Engineering Branch, DE/NRR,

/

which transmitted a summary report from Dominion Engineering, Inc., entitled Flaw Distributions for Example Plants". Please place the memorandum and report in the PDR.