February 20,ul997 Ms. Irene Johnson, Acting Manager Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West III 1400 Opus Place, Suite 500 Downers Grove, IL 60515

SUBJECT:

PROTECTED AREA ACCESS CONTROL AT NUCLEAR REACTOR SITES

Dear Ms. Johnson:

The Nuclear Regulatory Commission (NRC) is notifying all nuclear power reactor licensees of a potential problem involving the protected area access control-system that may exist at your sites. As a result of an unauthorized entry at one of the operating reactor sites, the NRC has determined that this situation may be a generic problem that should be analyzed by all licensees to verify that regulatory requirements are being met.

This letter is to-inform you that information is being provided to your plant security managers that could assist in your efforts to protect your plants against the " insider" requirement of the design-basis threat.

This information includes a Safeguards Information enclosure that is being sent only to your site security managers.

The enclosure is being withheld from public disclosure due to the sensitive information that it contains.

It is suggested that the information in the safeguards enclosure be reviewed for applicability to your plants and actions be considered, as appropriate.

Should you have any questions, please contact'Barry Manili in the Safeguards Branch, Office of Nuclear Reactor Regulation at (301) 415-2912.

Sincerely, ORIGINAL SIGNED BY:

1

Robert A. Capra, Director Project Directorate;III-2

. Division of Reactor _ Projects - III/IV Office of Nuclear Reactor Regulation Docket Nos. STN 50-454, STN 50-455, STN 50-456, Distribution:-

STN 50-457, 50-10, 50-237,150-240, 50-373, Docket-File PUBLIC >

50-374, 50-254, 50-265, 50-295, 50-304

. PDIII-2 r/f JRoe, JWR l

'RCapra EAdensam, EGAl t

Enclosure:

As stated CMoore RAssa GDick SBailey l

cc:

see next page MWebb JStang Ofh DSkay LRossbach C

%h1 CShiraki' MDapas, RIII gg~gJ ACRS, T2E26 OGC, 015B18 DLynch RLanksbury, RIII RPulsifer PHiland, RIII J

. DOCUMENT NAME:

G:\\CMNTJR\\ALPLANTS\\SFGUARDS.LTR l

T3 teceive a copy of this document,indicAin the box: "C" = Copy without enclosures *E" = Copy with enclosures "N" = No copy i

OFFICE D:PDIII-2 lV LAiVMIII-2 l6 l

l l

t NAME-RCAPRA:acm (M90R$.

DATE 02/JG'/97 02/\\f/97 ner'CIAL RECORD COPY 9702260317 970220 PDR ADOCK 05000010 p

PDR l

February 20, 1997 l

Ms. Irene Johnson, Acting Manager Nuclear Regulatory Services Co monwealth Edison Company Executive Towers West III 1400 Opus Place, Suite 500 Downers Grove, IL 60515

SUBJECT:

PROTECTED AREA ACCESS CONTROL AT NUCLEAR REACTOR SITES

Dear Ms. Johnson:

The Nuclear Regulatory Commission (NRC) is notifying all nuclear power reactor licensees of a potential problem involving the protected area access control system that may exist at your sites. As a result of an unauthorized entry at one of the operating reactor sites, the NRC has determined that this situation may be a generic problem that should be analyzed by all licensees to verify that regulatory requirements are being met.

This letter is to inform you that information is being provided to your plant security managers that could assist in your efforts to protect your plants against the " insider" requirement of the design-basis threat.

This information includes a Safeguards Information enclosure that is being sent only to your site security managers.

The enclosure is being withheld.from public' disclosure due to the sensitive information that it contains.

It is suggested that the information in the safeguards enclosure be reviewed for applicability to your plants and actions be considered, as appropriate.

Should you have any questions, please contact Barry Manili in the Safeguards Branch, Office of Nuclear Reactor Regulation at (301) 415-2912.

Sincerely, ORIGINAL SIGNED BY:

Robert A. Capra, Director Project Directorate III-2 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation Docket Nos. STN 50-454, STN 50-455, STN 50-456, Distribution:

STN 50-457, 50-10, 50-237, 50-249, 50-373, Docket File PUBLIC 50-374, 50-254, 50-265, 50-295, 50-304 PDIII-2 r/f JRoe, JWR RCapra EAdensam, EGA1

Enclosure:

As stated CMoore RAssa GDick SBailey cc: see next page MWebb JStang DSkay LRossbach CShiraki MDapas, RIII i

DLynch RLanksbury, RIII 1

i ACRS, T2E26 OGC, 015818 t

RPulsifer PHiland, RIII i

DOCUMENT NAME: G:\\CMNTJR\\ALPLANTS\\SFGUARDS.LTR Ta receive a copy of this Mr ;, indei min the box: "C" = Copy without enclosures *E" = Copy with enclosures *N* = No copy 0FFICE D:PDIII-2 lW LAW AIII-2 l 6 l

l l

1 t

l NAME RCAPRA:acm (190R$.

I DATE 02/JG'/97 02/\\M/97 0FFICIAL RECORD COPY

amuyk UNITED STATES g

g j

NUCLEAR REGULATORY COMMISSION t

WASHINGTON, D.C. 20edb0001

\\...../

February 20, 1997 Ms. Irene Johnson, Acting Manager Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West III 1400 Opus Place, Suite 500 Downers Grove, IL 60515

SUBJECT:

PROTECTED AREA ACCESS CONTROL AT NUCLEAR REACTOR SITES

Dear Ms. Johnson:

The Nuclear Regulatory Commission (NRC) is notifying all nuclear power reactor licensees of a potential problem involving the protected area access control system that may exist at your sites. As a result of an unauthorized entry at one of the operating reactor sites, the NRC has determined that this situation may be a generic problem that should be analyzed by all licensees to verify that regulatory requirements are being met.

This letter is to inform you that information is being provided to your plant security managers that could assist in your efforts to protect your plants against the " insider" requirement of the design-basis threat.

This information includes a Safeguards Information enclosure that is being sent only to your site security managers. The enclosure is being withheld from public disclosure due to the sensitive information that it contains.

It is suggested that the information in the safeguards enclosure be reviewed for applicability to your plants and actions be considered, as appropriate.

Should you have any questions, please contact Barry Manili in the Safeguards Branch, Office of Nuclear Reactor Regulation at (301) 415-2912.

Sincerely, N 0. {

Robert A. Capra, Director Project Directorate III-2 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation Docket Nos. STN 50-454, STN 50-455, STN 50-456,

~

STN 50-457, 50-10, 50-237, 50-249, 50-373, 50-374, 50-254, 50-265, 50-295, 50-304

Enclosure:

As stated cc: see next page

l I. Johnson Comonwealth Edison Company cc w/o enc 1:

l Michael I. Miller, Esquire Chairman, Ogle County Board Sidley and Austin Post Office Box 357 One First National Plaza Oregon, Illinois 61061 i

Chicago, Illinois 60603 Mrs. Phillip B. Johnson Regional Administrator, Region III 1907 Stratford Lane U.S. Nuclear Regulatory Comission Rockford, Illinois 61107 801 Warrenville Road l

Lisle, Illinois 60532-4351 George L. Edgar Morgan, Lewis t.nd Bochius Illinois Department of 1800 M Street, N.W.

Nuclear Safety Washington, DC 20036 Office of Nuclear Facility Safety l

1035 Outer Park Drive Attorney General Springfield, Illinois 62704 500 South Second Street Springfield, Illinois 62701 Document Control Desk-Licensing Commonwealth Edison Company EIS Review Coordinator l

1400 Opus Place, Suite 400 U.S. Environmental Protection Agency l

Downers Grove, Illinois 60515 77 W. Jackson Blvd.

Chicago, Illinois 60604-3590 Mr. William P. Poirier, Director Westinghouse Electric Corporation Commonwealth Edison Company Energy Systems Business Unit Byron Station Manager Post Office Box 355, Bay 236 West 4450 North German Church Road l

Pittsburgh, Pennsylvania 15230 Byron, Illinois 61010 Joseph Gallo Kenneth Graesser, Site Vice President Gallo & Ross Byron Station 1250 Eye St., N.W.

Comonwealth Edison Station Suite 302 4450 N. German Church Road Washington, DC 20005 Byron, Illinois 61010 Howard A. Learner U.S. Nuclear Regulatory Commission Environmental law and Policy Braidwood Resident Inspectors Office Center of the Midwest Rural Route #1, Box 79 203 North LaSalle Street Braceville, Illinois 60407 l

Suite 1390 Chicago, Illinois 60601 Mr. Ron Stephens Illinois Emergency Services U.S. Nuclear Regulatory Comission and Disaster Agency Byron Resident Inspectors Office 110 East Adams Street 4448 North German Church Road Springfield, Illinois 62706 Byron, Illinois 61010-9750 Chairman l

Ms. Lorraine Creek Will County Board of Supervisors Rt. 1, Box 182 Will County Board Courthouse Manteno, Illinois 60950 Joliet, Illinois 60434

l Comonwealth Edison Company Chairman Braidwood Station Manager Rock Island County Board Rt. 1, Box 84 of Supervisors Braceville, Illinois 60407 1504 3rd Avenue Rock Island County Office Bldg.

Ms. Bridget Little Rorem Rock Island, Illinois 61201 Appleseed Coordinator 117 North Linden Street Chairman Essex, Illinois 60935 Grundy County Board 1

Administration Building i

Mr. H. G. Stanley 1320 Union Street Site Vice President Morris, Illinois 60450 Braidwood Station Comonwealth Edison Company Mr. L. William Pearce RR 1, Box 84 Station Manager Bracemille, IL 60407 Quad Cities Nuclear Power Station 22710 206th Avenue North Site Vice President Cordova, Illinois 61242 l

Dresden Nuclear Power Station 6500 North Dresden Road U.S. Nuclear Regulatory Comission Morris, Illinois 60450-9765 Quad Cities Resident Inspectors Office 22712 206th Avenue North Station Manager Cordova, Illinois 61242 Dresden Nuclear Power Station 6500 North Dresden Road Phillip P. Steptoe, Esquire Morris, Illinois 60450-9765 Sidley and Austin One First National Plaza U.S. Nuclear Regulatory Comission Chicago, Illinois 60603 i

Resident Inspectors Office Dresden Station Assistant Attorney General 6500 North Dresden Road 100 West Randolph Street Morris, Illinois 60450-9766 Suite 12 Chicago, Illinois 60601 Richard J. Singer Manager - Nuclear U.S. Nuclear Regulatory Comission MidAmerican Energy Company Resident Inspectors Office LaSalle Station 907 Walnut Street 2605 N. 21st Road P.O. Box 657 Marseilles, Illincis 61341-9756 Des Moines, Iowa 50303 l

Chairman Brent E. Gale, Esq.

LaSalle County Board of Supervisors Vice President - Law and LaSalle County Courthouse MidAmerican Energy Company Ottawa, Illinois 61350 Regulatory Affairs One Rivertenter Place Chairman 106 East Second Street Illinois Comerce Comission P.O. Box 4350 Leland Building Davenport, Iowa 52808 527 East Capitol Avenue Springfield, Illinois 62706

LaSalle Station Manager LaSalle County Station Rural Route 1 P.O. Box 220 Marseilles, Illinois 61341 Robert Cushing Chief, Public Utilities Division Illinois Attorney General's Office 100 West Randolph Street Chicago, Illinois 60601 Dr. Cecil Lue-Hing Director of Research and Development Metropolitan Sanitary District l

of Greater Chicago 100 East Erie Street Chicago, Illinois 60611 j

Mayor of Zion Zion, Illinois 60099 U.S. Nuclear Regulatory Commission Zion Resident Inspectors Office 105 Shiloh Blvd.

Zion, Illinois 60099 Station Manager l

Zion Nuclear Power Station 101 Shiloh Blvd.

Zion, Illinois 60099-2797 4

k i

I

( cc w/ encl:

Commonwealth Edison Company Steve Rooney, Braidwood Station Security Adm.

Rural Route #1, Box 84 Braceville, Illinois 60407 Commonwealth Edison Company Scott Mills, Byron Station Security Adm.

4450 North German Church Road Byron, Illinois 61010 Commonwealth Edison Company Phil Braghini, Dresden Security Sup.

6500 North Dresden Road Morris, Illinois 60450-9765 Commonwealth Edison Company Brian Finlay, LaSalle Station Security Adm.

Rural Route #1, Box 220 Marseilles, Illinois 61314 Commonwealth Edison Company Keith Leech, Quad Cities Station Sucurity Adm.

22710 206th Avenue North Cordova, Illinois 61242 Commonwealth Edison Company Salvatore J. Della Fave, Zion Station Security Adm.

101 Shiloh Blvd Zion, Illinois 60099-2797

,