NPDES Noncompliance Notification:On 850730,large Input of Oil Overloaded Wastewater Treatment Sys.Source of Oil Undetermined.Suspected Causes Include Polymer & Oil Separator Weir Sys.Sys Isolated & Cleaned
ML20134P724
Person / Time
Site: LaSalle  
Issue date: 08/27/1985
From: Diederich G
COMMONWEALTH EDISON CO.
To: James Keppler
ENVIRONMENTAL PROTECTION AGENCY, ILLINOIS, STATE OF, NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 8509090033
Download: ML20134P724 (3)


Text

,

LASALLE COUNTY NUCLEAR GENERATING STATION N.P.D.E.S. PERMIT NO:

ILOO48151 NONCOMPLIANCE REPORT DISCHARGE NUMBER AND DESCRIPTION: 001(c) Wastewater Treatment Facility Effluent i

PARAMETER AND PERMIT LIMIT: Total Suspended Solids, 30 ppm daily maximum Oil and Grease, 20 ppm daily maximum Total Suspended Solids,15 ppic 30 day average Oil and Grease, 15 ppm 30 day average NONCOMPLIANCE, DATE, AND DURATION:

179.*1 ppm Total Suspended Solids, 30JUL85, unknown 69.2 ppm Oil and Grease, 29JUL85, unknown 41.1 ppm Total Suspended Solids, JUL85, 30 day average 18.4 ppm Oil and Grease, JUL85, 30 day average CAUSE OF NONCOMPLIANCE:

A large input of oil overloaded the Wastewater Treatment System. The polymer system was suspected to be ineffective since the polymers had exceeded the recommended shelf life. The weir system on the oil separator was suspected to be malfunctioning. The exact source of the oil is still unknown.

CORRECTIVE ACTION:

The Wastewater Treatment Facility was isolated to prevent discharge into the cooling pond. The equalization tank mixer was taken out of service.

The filter material in media filter "A" was replaced. The oil was pumped out of the equalization tank, clarifiers, clearwell, and e##1uent compartment. Oil absorbent booms in the clearwell and effluent chamber were replaced. The polymer system was restored to proper operating condition. The vendor for the oil separator was contacted and advised irispection of the oil separator trough. The inspection is in progress and work is being done under work request L50669.

DATE RECOGNIZED AS A VIOLATION:

30JUL85 DATE ItNESTIGATED:

30JUL85 8509090033 850827 PDR ADOCK 05000373 S

PDR DOCUMENT ID 0070h/0250A

p h. Commonwe:lth Edison

) RuralRouto #1 Box 220LaSalle County Nuclear Station O

d t

Fitf0'11rY RTJ e n Marseilles, Illinois 61341

- Telephono815/357-0761 Qf.11 pcmd r-kN(

.n T

x 610 Y'

Yr k._

iT1W August 27, 1985 Mr. James G. Keppler Regional Administrator Region III U.S. Nuclear Regulatory Commission

- 799 Roosevelt Road Glen Ellyn, Illinois 60137

Dear Mr. Keppler:

In accordance with IASalle County Station Unit 1 and Unit 2 Facility.

Operating License NPF-11 and NPF-18, Appendix B, Section 3.2, we are submitting to you a copy of the NPDES noncompliance for LaSalle County Nuclear Generating Station Permit No. IID0h8151.

408ap 2: #

6fG.-J.Diederich Station Manager InSalle County Station GJD/FRL/SKS/sga Enclosure J

xc: NRC Resident Inspector INPO - Records Center

.US NRC Document Control Desk

/i 0

y f6%

> i AUG 291986 h..

j

N Comm:;nwrahh Edison LaSalla County Nucizar Station

, d) c f

kV

Rural Route #1, Box 220 Marseilles, Illinois 61341

\\

Telephone 815/357-6761 August 9, 1985 U. S. Environmental Protection Agency Region V, Enforcement Division ATTW: Chief, compliance Unit 230 South Dearborn Street Chicago, IL 60604 Illinois Environmental Protection Agency Division of Water Pollution Control Compliance Management Unit 2200 Churchill Road Springfield, IL 62706

Dear Sir:

Subject:

NPDES Noncompliances for LaSalle County Nuclear Generating Station - Permit No. ILOO48151 In accordance with Standard Condition 12, we wish to submit the following notice of noncompliances which are listed on the attached table.

If there are any questions, please contact Steve Davis of r f staff at (815) 357-6761, extension 487.

w Wf G. J. Diederich'

)

Station Manager GJD/ L/SKD/msh xc: Director of Water Quality, Environmental Affairs Manager. Nuclear Stations Division DOCUMENT ID 0070h/0250A l\\

,