ML20134P045

From kanterella
Jump to navigation Jump to search
Notifies That Installation of Qualified Cables & Connectors to Victoreen high-range Radiation Monitors Completed on 850801.Monitors Now Environmentally Qualified.Justification for Interim Operation Considered Canceled
ML20134P045
Person / Time
Site: Crane Constellation icon.png
Issue date: 08/30/1985
From: Wilson R
GENERAL PUBLIC UTILITIES CORP.
To: Stolz J
Office of Nuclear Reactor Regulation
References
5211-85-2142, RFW-0602, RFW-602, NUDOCS 8509060119
Download: ML20134P045 (1)


Text

~

l l

i GPU Nuclear Q

gf 100 Interpace Parkway Parsippany. New Jersey 07054 201 263-6500 TELEX 136-482 Writer's Direct Dial Number:

August 30, 1985 5211-85-2142 RFW-0602 Office of Nuclear Reactor Regulation Attn: John F. Stolz, Chief Operating Reactors Branch #4 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D. C. 20555 Three Mile Island Nuciear Station Unit 1 (TMI)

Operating License No. DPR-50 Docket No. 50-289 EQ-Victoreen Monitors On August 1, 1985 GPUN completed installation of the qualified cables and connectors to the high range radiation monitors (RMG-22/23) manufactured by Victoreen. These in-containment monitors are now environmentally qualified as shown in EQ file (EQ-T1-144) which is available in our central file. Therefore, our Justification of Interim Operation (JIO-T1-84-9 Rev. 2) is considered cancelled.

' cere ly, r

.s. F.

i son Director Technical Functions

Reference:

GPUN letters dated 3/25/85 (5211-85-2059)

NRC letter dated 3/29/85 RFW:gpa 2279f/001 cc: J. Thoma R. Conte 8509060119 850830

/

DR p

ADOCK 05000289 O

PDR g

GPU Nuclear is a part of the General Public Utilities System