ML20134N919
| ML20134N919 | |
| Person / Time | |
|---|---|
| Site: | 07000925, 07001193 |
| Issue date: | 08/21/1985 |
| From: | Munson S KERR-MCGEE CORP. |
| To: | James Keppler NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| NUDOCS 8509060044 | |
| Download: ML20134N919 (3) | |
Text
!
cQs*
KERR-McGEE CORPORATION enicnnY '1"I hd Y~
f uran ucoce crNTra. ontawou4 ciTT. omtawou. nus au_@rc----
stL Das ML ENVmoNMENT AND HEALTw MANAGEMENT DevlSiON k b
-=I-T NV-E August 21, 1985 IIL M CERTIFIED MAIL RETURN RECEIPT REQUESTED Mr. James G.
Keppler, Director Inspection Branch r
Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Re:
Docket 70-925 and Docket 70-1193
Dear Mr. Keppler:
In accordance with 10 CFR 70-59, Sequoyah Fuels Corporation reports the release of SNM in effluents to the unrestricted area during the first half of 1985.
This report covers activities performed at our Cimarron Facility near Crescent, Oklahoma under license numbers SNM-928 and SNM-ll74.
Sincerely,
/
<nVM S.C.
Munson SCM/br cc:
Director of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.
20555 William T.
Crow, Acting Chief Uranium Fuel Licensing Branch U.S. Nuclear Regulatory Commission
/g Washington, D.C.
20555 N
AUG 2 61985 8509060044g%B2 p5 PDR ADOCK O PDR.
C i
t
'L o
(
License SNM-928 Table I i
e Radioactivity in Gaseous Effluents First Half 1985 Par *iculates Elevated and Total Release, No Batch Mode i
I First Second Unit Quarter Quarter Gross Alpha
- Ci 9.95 E-06 3.86 E-06 Average Concentration uCi/ml 2.41 E-12 4.03 E-13 Average Release Rate uCi/sec 1.27 E-06 4.91 E-07 4
1' From enriched uranium containing 2.7 percent U-235.
4 N
Table II No liquid effluent released.
l i
(.
License SNM-1174 Table I Radioactivity in Gaseous Effluents First IIalf 1985 Particulates Elevated and Total Release, No Batch Mode First Second Unit Quarter Quarter Gross Alpha
- Ci 1.81 E-07 7.34 E-07 Average Concentration uCi/ml 1.15 E-15 3.95 E-15 Average Release Rate uCi/sec 2.30 E-08 9.33 E-08 From plutonium containing 86 percent Pu-239 and 12 per-cent Pu-240.
Table II No liquid effluent released.