D (G

I REGISTRY OF RADI0 ACTIVE SEALED SOURCES *ND DEVICES SAFETY EVALUATION OF SEALED SOURCE N0.:

NR42051410 DATE:

May 02, 1963 PAGE 10F 2 1

SEALED SOURCE TYPE:

Beta Gauge Source 110 DEL:

S-75 NANUFACTURER/ DISTRIBUTOR:

LFE Corporation 1601 Trapelo Rd.

Waltham, MA 02154

)

MANUFACTURER / DISTRIBUTOR:

ISOTOPE:

Krypton-85 MAXIMUM ACTIVITY:

500 mil 11 curies Uq f

LEAK TEST FRE0VENCY:

PRINCIPAL USE:

Beta Gauges 1

CUSTOM SOURCE:

YES X N0 l

l 1

i 9702240218 630502 PDR RC SSD PDR

i REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE N0.: NR420 S141 U DATE:

liay 02,1963 PAGE 2 0F 2 SEALED SOURCE TYPE:

Beta Gauge Source I

DESCRIPTION:

l Consists of 500 millicuries of krypton-85 in gaseous form deposited in container as per procedures in specification sheet A 2213.g (see file). After gas has entered cavity through soft copper tube, it is severed forming cold welded joint prior to soft soldering.

fiodel S-75 source is firmly secured within Tracerlab Model DH-75 backscatter beta gauge by 3 screw-type fasteners.

Capable of withstanding 200 psi without leak or rupture.

LABELING Each source contains a warning plate as per Dwg. Nos. B-209648 & A-231357.

OUALITY ASSURANCE AND CONTROL:

All sources are helium leak tested before shipment to user.

ISSUING AGENCY:

U.S. Atomic Energy Connission

William R. Prendergast LFE Industrial Systems Corporation 55 Green Street Clinton, MA 01510 I

\\

Dear Mr. Prendergast:

j l

This letter is in reference to your letter dated August 6,1991, which requested that we transfer the registration certificates listed in column 1 of

to inactive status. The certificates have been transferred to inactive status as you have requested.

Please note that transfer of the i

2 registration certificates to inactive status means the sources or devices included on the certificates may no longer be commercially distributed.

The registration numbers for the certificates have been changed.

specifies the old registration number, the new registration number, and the model numbers.

Please note that some old certificates have been combined into one new inactive certificate.

In addition, two registration certificates have been deleted from the system since they were duplicates of other certificates.

Please review the registration certificates (copies enclosed in their entirety and notify us immediately if there are any errors or) omissions.

If you have any questions, please call me at (301) 415-7868 or Mr. Steven l

Baggett at (301) 415-7273.

l Sincerely, l

}O 1

i

/Q John W. Lubinski, Mechanical Engineer Sealed Source Safety Section Source Containment and Devices Branch 4

Division of Industrial and Medical Nuclear Safety 1

Office of Nuclear Material Safety And Safeguards

Enclosures:

As stated cc: S. Kirnberley, LFDCB Distribution:

SCDB r/f SSD-91-86 NE01 SSD Files listed in column 1 of enclosure 1 of this letter

- DOCUMENT NAME: C:\\ FILES \\SSDS\\LFE\\LFE. CMP I Ta,eceive e copy of this document, Indicate in the box: *C" = Copy without attachment / enclosure

  • E" = Copy with attachment / enclosure
  • N' = No copy OFFICE SCDB

.t, is lo l

l l

l

)

NAME JLubiriski/jl

~

DATE 09/Ji/95 0FFICIAL RECORD COPY a,. -

> ~

ao v

r 1

l ENCLOSURE 1 Old Reg. Number New Reg. Number Model Number (s) l NR-420-D-101-U NR-420-0-801-S Keleket-Barnes Rotary NR-420-D-102-U NR-420-D-802-S Keleket-Barnes Shperay NR-420-D-103-U NR-420-D-803-S Keleket-Barnes Ceiling l

Mounted Unit l

NR-420-S-104-S NR-420-S-804-S S-10 l

NR-420-D-106-U NR-420-D-805-S Keleket-Barnes Flexaray I

NR-420-S-107-U NR-420-S-806-S RXA, RXB, RXC, RXL, RXN, RXN l

NR-420-D-108-U NR-420-D-807-B SCL-10 NR-420-0-109-B NR-420-D-808-B BGL-7C certificates were BGL-7 NR-420-D-Il0-G combined BGL-IC NR-420-D-111-B NR-420-D-112-B NR-420-D-809-B BGL-1 NR-420-D-Il3-B NR-420-D-810-B S0-70, S0-7E certificates were S0-7A, 50-78, S0-7C NR-420-D-Il4-B combined NR-420-D-Il5-B NR-420-D-811-B S0-1A, 50-18, 50-1C NR-420-D-Il6-B NR-420-D-812-B SN-7D, SN-7E certificates were SN-7A, SN-78, SN-7C NR-420-D-Il7-B combined NR-420-D-Il8-B NR-420-D-813-8 SN-1A, SN-1B, SN-lC, SN-10, SN-1E, SN-1F NR-420-D-119-B NR-420-D-814-B SC-70, SC-7E NR-420-D-120-B NR-420-D-815-B SC-7A, SC-7B, SC-7C j

NR-420-D-121-B NR-420-D-816-B SC-1A, SC-1B, SC-1C, SC,lD, SC-lE, SC-1F 1

NR-420-D-122-B NR-420-D-817-B SN-P78 NR-420-D-124-B NR-420-D-818-B SCL-1A and SCL-1B NR-420-D-125-G NR-420-D-819-B SN-P7A4 l

l NR-420-D-126-U NR-420-D-820-B HSB-76 and HSB-77 1

l NR-420-D-127-G NR-420-D-821-G HSB-76A and HSB-77A L

1 L

. _. _.. _ _.. _ _. _. _ _ _. ~.. _ _ _

i i

L i

J i

ENCLOSURE 1 1

l l

Old Reg. Number New Rag. Number Model Number (s)

NR-420-0-128-G NR-420-D-822-G BGL-7A NR-420-D-132-G NR-420-D-823-G SNF-18 NR-420-D-133-G NR-420-D-824-G SSL-3 l

NR-420-S-137-U NR-420-S-826-S R-30, R-31 l

NR-420-S-138-U NR-420-S-827-S CD-1 NR-420-D-139-U NR-420-D-828-S SC-Il

)

NR-420-D-140-U NR-420-D-829-B DH-75 4

i' NR-420-S-141-U NR-420-S-830-S S-75 1

i NR-420-D-142-U NR-420-D-831-S AX-4 i

NR-420-D-143-U NR-420-D-832-S BG-107 l

NR-420-0 144-U NR-420-D-833-S BG-105 I

NR-420-D-145-U NR-420-D-834-S BG-7 5

NR-420-D-146-U NR-420-D-835-S BG-5 NR-420-D-147-U NR-420-D-836-S BG-2/5 NR-420-D-151-B deleted from system -

1 same as old registration NR-420-D-117-B J

NR-420-D-152-U NR-420-D-840-B SC-9C f

NR-420-S-154-U NR-420-S-842-S S-9 NR-420-S-155-U NR-420-S-843-S R-58, R-59 NR-420-S-156-U NR-420-S-844-S CS-15 NR-420-S-157-U NR-420-S-845-S CD-15 i

NR-420-S-158-U deleted from system -

same as old registration NR-420-S-156-U I

NR-420-D-159-U NR-420-D-846-S SC-11A i

NR-420-D-160-U NR-420-D-847-S Clathrate Gas Detector i

NR-420-S-163-U NR-420-S-849-S CD-11 l

NR-470-D-164-R NR-470-D-R50-R SN-PIB I'

2

..=

~

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE h NR-420-S-830-S DATE: ' September 28, 1995 PAGE 1 OF 3 SEALED SOURCE TYPE:

Beta Gauge Source l

MODEL:

S-75 4

i

l l

MANUFACTURER / DISTRIBUTOR:

LFE Industrial Systems Corporation 55 Green Street j

Clinton, MA 01510 i

i ISOTOPE:

MAXIMUM ACTIVITY:

Krypton-85 500 millictiries (18.5 GBq) 1 a

5 LEAK TEST FREOUENCY:

Not Required i

PRINCIPAL USE:

(E) Beta Gauges CUSTOM SOURCE:

YES X

NO i

m

-h 7 (?m 9 h o '1

,nj g.s.

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES l

SAFETY EVALUATION OF SEALED SOURCE NO.: NR-420-S-830-S DATE:

September 28, 1995 PAGE 2 OF 3 SEALED SOURCE TYPE:

Beta Gauge Source DESCRIPTION:

The source consists of 500 millicuries of krypton-85 in gaseous j

form deposited in a container.

After gas has entered the cavity through soft copper tube, it is severed forming a cold welded joint prior to soft soldering.

LABELING:

LFE has no information concerning how the sources are labeled.

CONDITIONS OF NORMAL USE:

The source is used in LFE Model DH-75 backscatter beta gauges and is held in place by 3 screw-type fasteners.

PROTOTTPE TESTING:

A prototype of the source was tested to ensure it is capable of withstanding 200 psi (1400 kPa) of pressure without leak or rupture.

EXTERNAL RADIATION LEVELS:

The source was only used in the Model DH-75.

Therefore, reference the certificate for the Model DH-75 for the radiation levels from the source when in use.

LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:

  • The sealed source may be used by specific licensees of NRC or Agreement States when used in a Model DH-75 gauging device.
  • Handling, storage, use, transfer, and disposal:

To be determined by the licensing authority.

l j

i i

REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES I

j SAFETY EVALUATION OF SEALED SOURCE i

I l

NO.: NR-420-S-830-S DATE:

September 28, 1995 PAGE 3 OF 3 1

SEALED SOURCE TYPE:

Beta Gauge Source

]

l'

{

LIMITATIONS AND/OR OTHRR CONSIDERATIONS OF USE (Cont.L1 j

This registration sheet and the information contained within e

the references shall not be changed without the written j

consent of the NRC.

i 4

i SAFETY ANALYSIS

SUMMARY

The Model S-75 sealed source is no longer distributed by the LFE.

j LFE has indicated that it has distributed approximately 6 sources under Model S-75 designation.

LFE may. accept return of the sources.

i

REFERENCES:

The'fo11owing supporting documents'for the Model S-75 sealed source are hereby incorporated by reference and are made a part 1

).

of this registry document, a

]

LFE's letters dated September 5, 1995, September 16,'1991, i

and August 6, 1991, with enclosures thereto.

l I

k ISSUING AGENCY:

l U.S. Nuclear Regulatory Commission

/

Date:

Seotember 28. 1995 Reviewer:

f j ohn W.

L binski j

Date:

September 28. 1995 Concurrence:

2f' Kbs6en L. kaggett

~.

_ ~...

_m

~

4 l

]

w-.==>

INFORMAT;ON RECORD TYPE:

Note to LFE files for registration certificates made inactive September 1995.

3 ORGANIZATION:

LFE DATE.

09/21/95 i

SUMMARY

Existing AEC/NRC files (registration files, license i

files, NUDOCS, and archives) concerning these products were examined for information that supports registration of the products.

Copies of all applicable information located is included in this file.

The manufacturer, LFE, l

information concerning the products.was also asked for additional l

However, man the products have not been distributed for years, y of the product lines were sold in the late 1960's, or and LFE provided all additional information they have concerning the products.

1 NRC has transferred the registration certificates to 4

(

inactive, as requested by LFE, and continues to conclude the products are acceptable for licensing purposes based on AEC's original evaluation of the products and the operational history of the products.

)

d PERSONS DOCUMENTING THE SIGNATURE:

INFORMATION:

/

DATE:

///YU

~

}

John W. Lubinski 7

09/21/95 Steven L..Baggett

,/

W a,