IR 05000601/2007031

From kanterella
(Redirected from ML20134M980)
Jump to navigation Jump to search
Notice of Violation from Insp on 850601-0731
ML20134M980
Person / Time
Site: Quad Cities, 05000601  
Issue date: 08/21/1985
From: Chrissotimos N
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20134M971 List:
References
50-254-85-17, 50-265-85-19, NUDOCS 8509040363
Download: ML20134M980 (1)


Text

{{#Wiki_filter:- . - Appendix NOTICE OF VIOLATION Comonwealth Edison Company Docket Nos. 50-254 Quad Cities Unit I and 2 50-265 As a result of tM inspection conducted June 1 through July 31, 1985, and in accordance with the General Policy and Procedures for NRC Enforcement Actions (10 CFR Part 2, Appendix C), the following violations were identified: 1.

Technical Specification Section 6.2 requires that detailed written procedures including applicable checkoff lists shall be prepared, approved and adhered to for normal operation of the reactor. QAP 300-7: " Shift Change for Nuclear Station Operators," requires that both the offgoing and oncoming operators check the control room panels persuant to QOS 005-2: " Normal Control Room Inspection and Shift Turnover Panel Check". Further, QOS 005-2 requires the High Pressure Coolant Injection (HPCI) system flow controller to be in the automatic position.

Contrary to the above, on July 11, 1985, an inadequate shift turnover was performed by both the offgoing and oncoming Unit 2 operators resulting in the HPCI flow controller being left in the manual position for a period of approximately eight hours.

This is a Severity Level IV violation (Supplement 1).

2.

10 CFR 50 Appendix B, Criterion XIII requires that measures shall be established to control the handling, storage, shipping, cleaning, and preservation of materials and equipment important to safety. QAP 600-13: Levels of Storage and Inspection Criterial, section C.3.b requires that openings in safety-related valves be capped, plugged or sealed.

Contrary to the above, the inspectors found two safety-related check valves in the station warehouse without the required protective covers ~ on the flanges.

This is a Severity Level V violation (Supplement 1).

Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office within thirty days of the date of this Notice a written statement or explanation in reply, including for each item of noncompliance: (1) corrective action taken and the results achieved; (2) corrective action to be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved. Consideration may be given to extending your response time for good cause shown.

AUG 211985 McA5

  • f( {{.~

Dated N. Chrtssotimos, Chief - Reactor Projects Branch 2 8509040363 e5002 PDR ADOCK 5000254 PDR G - }}