s November 18, 1996
' Mr. D. M. Smith, President PECO Nuclear Nuclear Group Hear' quarters
. Correspondence Control Desk P. O. Box 195 Wayne, Pennsylvania 19087-0195
SUBJECT:
PLANT PERFORMANCE REVIEW (PPR)- PEACH BOTTOM ATOMIC POWER STATION r
Dear Mr. Smith:
On November 7,1996, the NRC staff completed the semiannual Plant Performance Review (PPR) of the Peach Bottom Atomic Power Station. The staff conducts these reviews for all operating nuclear power plants to develop an integrated understanding of safety
]
performance. The results are used by NRC management to facilitate planning and
+
allocation of inspection resources. The PPR for Peach Bottom involved the participation of
_all technical divisions in evaluating inspection results and safety performance information j
for the period May 1996 through October 1996. PPRs provide NRC management with a current summary of licensee performance and serve as inputs to the NRC Systematic irssessment of Licensee Performance (SALP) and senior management meeting (SMM) reviews.
This letter advises you of our planned inspection effort resulting from the Peach Bottom PPR review. 'It is provided to minimize the resource impact on your staff and to allow for scheduling conflicts and personnel availability to be resolved in advance of inspector arrival onsite. The enclosure details our inspection plan for the next 6 months. The rationale or basis for each inspection outside the core inspection program is provided so that you are aware of the reason for emphasis in these program areas. Resident inspections are not listed due to their ongoing and continuous nature.
We willinform you of any changes to the inspection plan. If you have any questions, please contact Walter J. Pasciak at 610-337-5258.
ORIGINAL SIGNED BY:
Walter J. Pasciak, Chief Reactor Projects Branch 4 Division of Reactor Projects Docket Nos. 50-277;50-278
Enclosure:
' Inspection Plan
_T h Ii 9611260078 961118 PDR ADOCK 05000277
.G; PDR th -
. _ =. _ -
t Mr. D. M. Smith 2
l l
cc w/ encl:
G. A. Hunger, Jr., Chairman, Nuclear Review Board and Director, Licensing l
T. Mitchell, Vice President, Peach Bottom Atomic Power Station l
G. Rainey, Senior Vice President, Nuclear Operations i
D. B. Fetters, Vice President, Nuclear Station Support T. Niessen, Director, Nuclear Quality Assurance 1
C. D. Schaefer, External Operations - Delmarva Power & Light Co.
G. Edwards, Plant Manager, Peach Bottom Atomic Power Station G. J. Lengyel, Manager, Experience Assessment J. W. Durham, Sr., Senior Vice President and General Counsel P. MacFarland Goelz, Manager, Joint Generation, Atlantic Electric 1
l B. W. Gorman, Manager, External Affairs
)
l R. McLean, Power Plant Siting, Nuclear Evaluations l
J. Vannoy, Acting Secretary of Harford County Council l
R. Ochs, Maryland Safe Energy Coalition J. H. Walter, Chief Engineer, Public Service Commission of Maryland L. Jacobson, Peach Bottom Alliance i
Commonwealth of Pennsylvania State of Maryland TMI - Alert (TMIA) l I
i 4
J w
.. ~ _
i
- i. t
,o, l
Mr. D'. M. Smith 3
Distribution w/ encl:
Region l Docket Room (with concurrences)
K. Gallagher, DRP '
l Nuclear Safety information Center (NSIC)
D. Screnci,- PAO M. Oprendek, DRP NRC Resident inspector l
PUBLIC Distribution w/ encl: (Via E-Mail)
W. Dean, OEDO J. Shea, NRR J. Stolz, PDI 2, NRR Inspection Program Branch, NRR (IPAS)
R. Correia, NRR R. Frahm, Jr., NRR DOCUMENT NAME:
- \\br ch4\\pprltr.p To recehre a copy of this docu to in the boa: "C" = Copy without attachment / enclosure "E' = Copy with attachment / enclosure "N* = No copy
(,
l OFFICE RI:DRWf//f l
RI:Dy V l
l NAME PSwptfand WPa)ciak DATE 11/W96 11/ 796 OFF CIAL RECORD COPY L
!u I
3
4 PEACH BOTTOM INSPECTION PLAN IP NUMBER TITLE DATE-i Effectiveness of Licensee Controls in Identifying, Resolving, and IP 40500 - CO MM 97 Preventing Problems
- IP 37550 - CO Engineering - Visit 1_
1/13/97 IP 37550 - CO Engineering - Visit 2 -
1/27/97-IP 37550 - CO Engineering - Visit 3 3/3/97 IP 83750 - CO Occupational Radiation Exposure - Visit 2 12/2/96 Radioactive Waste Treatment and Effluent and Environmental IP 84750 - CO 12/9/96 Monitoring (Environs)
IP 83750 - CO Occupational Radiation Exposure - Visit 3 5/5/97 IP 82301 - CO Evaluation of Exercises for Power Reactors 11/18/96 IP 82701 - CO Operational Status of the Emergency Preparedness Program
'2/10/97 IP 81700 - CO Physical Security Program for Power Reactors 4/7/97 IP 64704 - CO Fire Protection Program 3/3/97 L
IP - NRC Inspection Procedure CO - Core inspection (NRC Program Requirement) j E
.I
.