ML20134M582

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 70-1359/85-03 on 850813,consisting of Confirmatory Survey of IRT Corp Fast Spectrum Cell.Facility Decontaminated & Meets NRC Guidelines for Release to Unrestricted Use
ML20134M582
Person / Time
Site: 07001359
Issue date: 08/29/1985
From: Thomas R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Wong G
CALIFORNIA, STATE OF
Shared Package
ML20134M584 List:
References
NUDOCS 8509040186
Download: ML20134M582 (1)


Text

. _ _ _ _ _ _ _ _

44

'o,,

UNITE 3 STATES e

NUCLEAR REGULATORY COMMISSION a

"v.'/

,E REGION V S.

4 1450 MARIA LANE SulTE 210

%, '

  • J

,o#

WALNUT CRE E K, CALIFORNI A 94596 AUG 2 91985 I

State of California State Department of flealth Services Radiological licalth Branch D N 7, -p O N,p /h3. O 1232 Q Street s.

Sacramento, California 95814 Attention: Dr. Gerard Won 8 carM"E Centlemen:

Subject:

Confirmatory Survey of IRT Corporation Fast Spectrum Cell located at 10955 John Jay liopkins Drive, San Diego, California Enclosed is our inspection report 70-1359/85-03 which contains the confirmatory survey of the subject facility.

Based upon the results of this survey, it was determined that the facility had been decontaminated and meets the NRC guidelines for release to unrestricted use.

If you havo queutions concerning the report or need additional information pleaso contact ehis office.

R. D. Thomas, Chief Nuclear Materials Safety Section

Enclosure:

As stated cc w/enclos,ure:

Jack Horner 050?O40106 050029 REOS LICQO SNM-1405 PDR 7L 4C1 i

,