ML20134M134

From kanterella
Jump to navigation Jump to search
NPDES Permit 3IB00016*ED,issued to Oh EPA
ML20134M134
Person / Time
Site: Perry 
Issue date: 02/01/1997
From: Schregardus D
ENVIRONMENTAL PROTECTION AGENCY
To:
Shared Package
ML20134M129 List:
References
3IB00016*ED, 3IB16*ED, NUDOCS 9702200107
Download: ML20134M134 (24)


Text

-

l Page 1 of 24 Ohio EPA Permit No. 3IB00016*ED l

43 /IE Application No. OH0063461 Issue Date: January 14, 1997 Effective Date:

February 1, 1997 Expiration Date: January 28, 2002 Ohio Environmental Protection Agency Authorization to Discharge Under the National Pollutant Discharge Elimination System In compliance with the provisions of the Federal Water Pollution Control Act, as amended (33 U.S.C.

1251 et. seq., hereinafter referred to as the "Act"), and the Ohio Water Pollution Control Act (Ohio Revised Code Section 6111),

Cleveland Electric Illuminating Company is authorized by the Ohio Environmental Protection Agency, hereinafter referred to 1

as " Ohio EPA," to discharge from the wastewater treatment works located at 10 Center Road, North Perry Village, Ohio, Lake County cnd discharging to Lake Erie in accordance with the conditions specified in Parts I, II, III, IV, and VI of this permit.

This permit is conditioned upon payment of applicable fees as required by Section 3745.11 of the Ohio Revised Code.

This perTnit and the authorization to discharge shall expire at midnight on the expiration date shown above.

In order to receive authorization to discharge beyond the above date of expiration, the permittee shall submit such information and forms cs are required by the Ohio EPA no later than 180 days prior to the above date of expiration.

Donald R. Schreg #dus Director l

{

l l

Form EPA 4428 9702200107 970214 PDR ADOCK 05000440 p

PDR

Page 2 of 24 Ohio EPA Permit No. 3IB00016*ED Part I, A.

- FINAL EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning on the effective date of this permit and lasting until the expiration date, the pemittee is authorized to discharge in accordance with the following limitations and monitoring requirements from outfall 3IB00016004.

See Part II, OTHER REQUIREMENTS, for locations of effluent sampling.

2 EFFLUENT CHARALitRISTIC DI5 CHARGE LIMIMTION5 MONITORING REQUIREMENT 5 Concentration Loading i

Reporting Specified Units kg/ day Neas.

Sample l

Code Units Parameter 30 day Daily 30 day Daily Freq.

Type 4

00011

'F Water Tenperature*

Daily Continuous 00665 mg/l Phosphorus, Total (P) 1/ Week Grab 50050 MGD Flow Rate Daily Continuous 50064 mg/l Chlorine, Free Available**

0.2 0.5 Daily Grab 4

There shall be no detectable amount in the discharge from this outfall of any priority pollutant, other than i

chromium and zine contained in chemicals added for cooling tower maintenance. As of the effective date of this permit, the permittee has stated it does not use chemicals for cooling tower maintenance that contain chromium or zine; therefore, this outfall does not contain enromim or zine effluent limitations as required by 40 CFR 423.15. If the permittee, in the future, uses chemicals for cooling tower maintenance which do contain chromi m or tinc, the permittee shall apply, prior to the use of the chemicals, for a modification of this permit so as to include the appropriate effluent limitations and monitoring requirements for 4

chromi m and/or rinc.

Requires intake (31800016800) monitoring. Report intake /outf all tenperature estimated to correspond to a maxima temperature dif ferential sustained for one hour.

Neither free available chlorine nor total residual chlorine may be discharged from any unit for more than two hours in any one day and not more than one unit in any plant may discharge free available or total residual chlorine at any one time unless the utility can oemonstrate to the state that the unit (s) in a particular location cannot operate at or below this levet of chlorination. Analyses are to be performed by emperometric titration, orin residual chlorine electrode, or other EPA spproved methods. $anpting at Outfall 004 shall be performed within the appropriate detention time of the chlorination dosage.

2.

The pH (Reporting Code 00400) shall not be less than 6.5 S.U. nor greater than 9.0 S.U.

and shall be monitored 2/ week by grab sample.

3.

Samples taken in compliance with monitoring requirements specified above shall be taken at Sampling Stations described in Part II, OTHER REQUIREMENTS.

1 Form EPA 4428

I Page 3 of 24 Ohio EPA Permit No. 3IB00016*ED Part I, A.

- FINAL EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning on the effective date of this permit and lasting until the expiration date, the permittee is authorized to discharge in accordance with the following limitations and monitoring requirements from outfall 3IB00016601.

See Part II, OTHER REQUIREMENTS, for locations of effluent sampling.

EFFLUENT CHARACTERISTIC DI5 CHARGE LIMITATION 5 MONITORING REQUIRtmtN15 Concentration Loading Reporting Specified Units kg/ day Meas.

Sample Code Units Parameter 30 day Daily 30 day Daily Freq.

Type 00530 mg/l Total Suspended Solids 30 100 1/2 Weeks' 24 Hr.Conposite 00550 mg/l oil and Grease, total 15 20 1/2 Weeks

  • Grab 50050 MGD Flow Rate Continuous 24 Hr. Total Sanpling shall be performed when discharging. If NO DISCHARGE OCCURS DURING THE ENTIRE MONTH, state this in the remarks section and LEAVE THE DATA AREA BLANK (signature still required).

2.

The pH (Reporting Codes 00402 (minimum) and 00401 (maximum) shall be monitored continuously and reported 1/2 weeks *.

3.

Samples taken in compliance with monitoring requirements specified above shall be taken at Sampling Stations described in Part II, OTHER REQUIREMENTS.

i 1

Form EPA 4428

l Page 4 of 24 Ohio EPA Permit No. 3IB00016*ED Part I, A.

- FINAL EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS

)

1.

During the period beginning on the effective date of this permit and lasting until the expiration date, the permittee is authorized to discharge in accordance with the following limitations and monitoring requirements from outfall 3IB00016602.

See Part II, OTHER REQUIREMENTS, for locations of effluent sampling.

EFFLUENT CHARALItRISTIC DISCHARGE LIMITATION 5 RONITORING REQUIREMENTS Concentration Loading Reporting Specified Units kg/ day Meas.

Sample Code Units Parameter 30 day Daily 30 day Daily Freq.

Type 00530 mg/l Total Suspended Solids 30 45 1/2 Weeks

  • 24 Hr. composite 00550 mg/l oil and Grease, Total 15 20 1/2 Weeks
  • Grab j

01042 ug/l Copper, Total (Cu) 1,000 1,000 1/2 Weeks' 24 Hr. composite 01045 pg/l Iron, Total (Fe) 1,000 1,003 1/2 Weeks

  • 24 Hr.Conposite 50050 MGD Flow Rate Continuous
  • 24 Hr. Total Sanpling shall be performed when discharging. If NC DISCHARGE OCCURS DURING THE ENTIRE MONTH, state this in the remarks section and LEAVE THE DATA AREA BLANK (signature still required).

2.

The pH (Reporting Code 00400) shall not be less than 6.5 S.U. nor greater than 9.0 S.U.

and shall be monitored 1/2 Week

3.

Samples taken in compliance with monitoring requirements specified above shall be taken at Sampling Stations described in Part II, OTHER REQUIREMENTS.

I Form EPA 4428

. - ~ _ _. _..

l Page 5 of 24 Ohio EPA Permit No. 3IB00016*ED l

l Part I, A.

FINAL EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning on the effective date of this permit and lasting until the expiration date, the permittee is authorized to discharge in accordance with the following limitations and monitoring requirements from t

outfall 3IB00016800.

See Part II, OTHER REQUIREMENTS, for locations of effluent l

sampling.

d EFFLUENT CHARACTERISTIC DISCHAMGE LIMITATION 5 RDNITORING REQUIREMENT 5 Concentration Loading Reporting Specified Units kg/ day Meas.

Sample l

Code Unite Parameter 30 day Dafty 30 day Daily Freq.

Type 00011

  • F Water Tamperature Daily continuous Samples nust be taken on the same day as those sanples of effluent used for determination of maximum tenperature differential.

Form EPA 4428

-~. -.

... - _ - - _ - _ -.---- - ~--. _........-

..~.

i C:

b i

4 i

i Page 6 of 24

[

Ohio EPA Permit No. 3IB00016*ED a

j Part I, A.

- FINAL EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS a

1.

During the period beginning.on the effective date of this permit and lasting j

until the expiration date, the permittee is authorized to discharge in accordance with the following limitations and monitoring requirements from outfall 3IB00016005.

See Part II, OTERR REQUIREMENTS, for locations of effluent sampling.

1 i

i EF FLUENT CMARAu tul5 TIC DIECMARGE LIMITATION 5 MUNITORING REGUInte nis Concentration Loading 9

Reporting Specifled Units kg/ day Mees.

Sanple Code Units Parameter 30 day Daily 30 day Dolly Freq.

Type This outfall is limited to stormwater runoff only and is to be free from any process related wastewater. General j

stormwater requirements are applicable. See Parts !!.H, IV, and VI.

I 1

I i

1 l

)

i 1

4 4

1 i

l l

a 4

f E

i i

1 4

i Form EPA 4428

~

l l

Page 7 of 24 Ohio EPA Permit No. 3IB00016*ED l

Part I, A.

- FINAL EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning on the effcetive date of this permit and lasting until the expiration date, the permittee is authorized to discharge in l

accordance with the following limitations and monitoring requirements from I

outfall 3IB00016006 & 007.

See Part II, OTHER REQUIREMENTS, for locations of effluent sampling.

EFFLUENT CHARACTERI5 TIC DISCHARGE LIMITATIONS N)NITORING REQUIREMENT 5 Concentration Loading Reporting Specified Units kg/ day Meas.

Sanple Code Units Parameter 30 day Daily 30 day Daily Freq.

Type the diacharge from outfall 31800016006 is limited to stormuster from the northwest storm drainage inpoundment.*

The -lischarge from outf all 3!B00016007 is limited to stormwater from the minor stream inpoundnent.*

General stormwater requirements are applicable. See Parts !!.H., IV, and VI.

i i

l Form EPA 4428

~-

\\

Page 8 of 24 Chio EPA Permit No. 3IB00016*ED l

Part II, OTHER REQUIR1 DENTS A.

Description of the location of the required sampling stations are as follows:

Samolina Station Descriotion of Location 3IB00016004 At a point representative of the discharge from the discharge tunnel entrance structure (Lat: 41'48'33"; Long: 81*08'50")

3IB00016005 At a point representative of the discharge from the major stream impoundment (Lat: 41847'58"; Long: 81*09'17")

31B00016006 At a point representative of the discharge from the northwest storm drainage impoundment (Lat: 41'48'05"; Long: 81*09'05")

31B00016007 At a point representative of the discharge from the minor stream impoundment (Lat: 41'48'21"; Long: 81*08'29")

1TB00016601 At a point representative of the discharge from the regenerant neutralization pits prior to entering outfall 004 31B00016602 At a point representative of the discharge from the chemical cleaning lagoons prior to entering outfall 004 3IB00016800 At inlet to the plant from Lake Erie B.

This permit shall be modified, or alternatively, revoked and reissued, to comply with any applicable effluent standard or limitation issued or approved under Sections 301(b) (2) (C) and (D), 3 04 (b) (2), and 307 (a) (2) of the Clean Water Act, if the effluent standard or limitation so issued or approved.

1.

Contains different conditions or is otherwise more stringent than any effluent limitation in the permit; or 2.

Controls any pollutant not limited in the permit.

The permit as modified or reissued under this paragraph shall also contain any other requirements of the Act then applicable.

C.

In the event that the permittee's operation requires the use of cooling or boiler water treatment additives that are discharged to surface waters of the state, written permission must be obtained from the director of the Ohio EPA prior to use.

Reporting and testing requirements to apply for permission to use additives can be obtained from the Ohio EPA Central Office, Division of Surface Water, Water Resource Management Section. Reported information will be used to evaluate whether the use of the additive (s) at concentrations expected in the final discharge will be harmful or inimical to aquatic life.

D.

On outfal.ls where pH is monitored continuously, the permittee shall maintain the pH of such wastewater within the range specified in this permit.

Excursions from the range are permitted subject to the following limitations.

1.

The total time during which pH values are outside the required range of pH values shall not exceed 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> and 26 minutes in any calendar month.

2.

Ne individual excursion from the range of pH values shall exceed 60 minutes.

s'osm EPA 4428

l l

r

{

Page 9 of 24 Ohio EPA Permit No. 3IB00016*ED Part II, OTHER REQUIREMINTS (continued)

D.

Continued 3.

The permittee shall report each month for each monitoring station where pH is monitored continuously the following.

a.

the number of pH excursions; b.

the duration of each excursion; c.

the date of each excursion; and d.

the total time of all excursions combined.

E.

Permit limitations may be revised in order to meet water quality standards after a stream use determination and waste load allocation are completed and approved.

This permit may be modified, or alternatively, revoked and reissued, to comply with any applicable water quality effluent limitations.

F.

There shall be no detectable amount of any priority pollutant attributable to cooling tower maintenance chemicals in the cooling tower blowdown wastewater.

G.

There shall be no discharge of polychlorinated biphenyl compounds attributable to the permittee's operations.

H.

The following non-storm water discharges may be authorized by this permit provided the non-storm water component of the discharge is in compliance with parag raph IV.D. 3.g : discharges from fire fighting activities; fire hydrant flushings; potable water sources including waterline flushings; irrigation i

drainage; drainage of non-treated lake water systems; lawn watering; routine external building washdown which does not use detergents; pavement washwaters I

where spills or leaks of toxic or hazardous materials have not occurred (unless all spilled material has been removed) and where detergents are not used; air conditioning condensate; springs; uncontaminated ground water; and foundation or footing drains where flows are not contaminated with process materials such as j

solvents.

j Form EPA 4428

Paga 10 of 24 Ohio EPA Permit No. 3IB00016*ED 1

j PART III - EERAL EXWITIONS

l. DEFINITIONS

" daily load limitations" is the total discharge by weight during any calender day. If only one sample is taken during a day, the weight of pollutant discharge calculated from it is th e 6elly lead.

" daily concentration timitation" means the arithuetic everage (weighted by flow) of all the determinations of concentration made diaring the day. If only one sample is taken during the day, its concentration is the daily concentration.

Collform bacteria limitations compliance shall be determined using the geometric mean.

"7 day toad limitation" is the total discharge by weight during any 7 day period divided by the nunteer of days in that 7-day period that the facility was in operation. If only one sample is taken in a 7-day period, the weight of pollutant discharge calculated from it is the 7-day load.

If more than one sample is taken during the 7-day period, the 7-day load is calculated by determining the daily load for each day sampled, totaling the daily loads for the 7 day period, and dividing by the rudser of days sampled.

"7-day concentration Unitation" means the arithmetic everage (weighted by flow) of all the determinations of 5

deity concentration timitation made during the 7-day period.

If only one sample is taken during the 7 day period, ions compliance shall be determined using the geometric mean.its concentration is the 7-day concentration limitat l

y load timitation" is the tote! discharge by weight durins any 30 day period divided by the ru dier of ys in the so-day period that the facility was in operation.

the weight of pollutant discharge calculated from it is the 30-day load,If only one sample is taken in a 30-day period, if more than one sample is taken during one 30-day period,for the 30-day period ano dividing by the number of days sampledthe 30 day lo totaling the daily loads "30 day concentration limitation" means the arithmetic average (weighted by flow) of all the determinations of deity concentration made during the 30-day period. If only one sample is taken daring the 30-day period, its

)

concentration is the 30-day concentration for that 30 day period. Cotiform bacteria timitations compliance shall be determined using the geometric mean.

1 4

"85 cereent removat limitations" means the arithmetic mean of the values for effluent sa mles collected in a period of 30 consecutive days shall not exceed 15 percent of the arithmetic mean of the values for influent j

sanples collected at approximately the same times during the same period.

i

" Absolute Limitations" Compliance with limitatloas having descriptions of "shall not be less than " "nor greater i

then," "shet t not exceed," "mininun," or "maximian" shall be determined from any single value for ef fluent samples

~

j and/or measurements collected.

i J

i

" Net concentration" shall mean the difference between the concentration of a given substance in a senple taken l

of the discharge and the concentration of the same substances in a senple taken at the intake which supplies water to the given process. For the purpose of this definition, samples that are taken to determine the net a

i concentration shall always be 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> composite samples made up of at least six increments taken at regular

]

intervals throughout the plant day.

"N l

shall mean the dif ference between the load of a given substance as calculated from a sample taken of i

te tsc.arge and the load of the same substance in a sample taken at the intake which angelies water to given

}.

process.

For purposes of this definition, sanples that are taken to determine the net loading shall always be 24-hour composite senples made @ of at least six increments taten at regular intervals throughout the plant day.

j "P,g " means million getLons per day.

4 "3g41" means alltigrams per liter.

"g 41" means micrograms per liter.

"senortina Code" is a five digit n6suber used by the Ohio EPA in processing reported data. The reporting code does not inpty the type of analysis used nor the sampling techniques employed.

"guarterly sanctina freauency" means the sampling shall be done in the months of March, June, August, and

+

Decentier.

" Yearly samotina freauency" means the sampling shall be done in the month of September, 4

b

" semi-annual sanctina fr=_-ry" means the sanpling shall be done during the months of June and December.

" Win.lE" shall be considered to be the period from hovember 1 through April 30.

"gyggn " means the intentiunal diversion of weste streams from any portion of the treatment facility.

"$ m ner" shall be considered to be the period from May 1 through October 31.

" Severe procerty demane" means substantial ph which would cause them to become inoperable, ysical damage to property, damage to the treatment facilities or substantial and permanent loss of natural resources which can reasonably be expected to occur in the absence of a bypass. Severe property damage does not mean economic loss a

l caused by delays in production, i

1 Form EPA 4428 4

-.m m

Page 11 of 24 Ohio EPA Permit No. 3IB00016*ED PART III - GENERAL CO SITIONS (continued)

"ynLei" means an exceptional incident in which there is unintentional and temporary noncompliance with technology based permit effluent limitations because of factors beyond the reasonocle control of the permittee.

An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment feellities, inadeounte treatment f acilities, lack of preventive maintenance, or careless or improper I

operation.

t

2. GENERAL EFFLUENT LINITATIONS The effluent shell, at all times, be free of stestances:

A.

In anomts that will settle to form putrescent, or otherwise objectionable, sludge deposits; or that will I

l adversely affect equetic life or water fowl; g.

Of an oily, greasy, or surface-active nature, and of other floeting debris, in amounts that will form noticeable acetsmalations of scun, foam or sheen; C.

In anom ts that will alter the natural color or odor of the receiving water to such degree as to create a nuisance; i

D.

In amounts that either singly or in combination with other substances are toxic to htsman, animal, or aquatic life; E.

In amounts that are conducive to the growth of aquatic weeds or algae to the extent that such growths l

become inimical to more desirable forms of aquatic life, or create conditions that are unsightly, or constitute a nuisance in any other fashion; F.

In amounts that will impelr designated instream or downstream water uses.

3.

FACILITY OPERATION AND QUALITY CONTROL All wastewater treatment works shall be operated in a manner consistent with the following:

A.

At all times, the permittee shall mainteln in good working order and operate as efficiently as possible all treatnernt or control f acilities or systems installed or used by the permittee necessary to achieve coupliance with the terms and conditions of this permit. Proper operation and maintenance also includes adequate lacoratory controls and appropriate quality assurance procedures. This provision regJires the l

ration of back up or auxiliary facilities or sieller systems which are installed by a permittee g)1y en the operation is necessary to achieve compliance with conditions of the permit.

P.

The permittee shall effectively monitor the operation and efficiency of treatment and control facilities and the quantity and quality of the treated discharge.

I C.

Maintenance of wastewater treatment works that results in degradation of effluent quality shall be scheduled during non-critical water quality periods and shall be carried out in a menner approved by the Ohio EPA as specified in the Paragraph in this PART III entitled, " UNAUTHORIZED DISCHARGES".

4.

REPORTlWG A.

Monitoring data required by this permit shall be reported on the Ohio EPA report form (4500) on a monthly basis. Individual reports for each sm pling station for each month are to be received no later than the 15th day of the next month. The criginal plus first copy of the report form must be signed and mailed to:

Chio Envirorunental Protection Agency Division of Surface Water Enforcement section ES/MOR P.O.gon1040 Coltsbus, ohto 43266 0149 g.

If the permittee monitors any pollutant at the location (s) designated hercin more frequently than required by this permit, using approved analytical methods as.pecified below the results of such monitoring shall be included in the calculation and reporting of the values re, quired in the reports specified above.

C.

Analyses of pollutants not required by this permit, except es noted in the preceding paragraph, shall not be reported on Ohio EPA report form (4500) but records shall be retained as specified in the paragraph entitled " RECORDS RETENTION".

5.

sAMPtthG AND ANALYTICAL METHODS Samples and measurements taken as required herein shall be representative of the voltane and nature of the monitored flow. Test procedures for the analysis of pollutants shall conform to regulation 40 CFR 136, " Test Procedures For The Analysis of Pollutants" mless other test procedures have been specified in this permit.

The permittee shall periodically calibrate and perform maintenance procedures on all monitoring and analytical instrtsnentation at intervals to insure accuracy of measurements.

l l

Form EPA 4428 i

+a.

a---

y.

-y.-a..

m

,m-m..--w m.,

->q-s e4--i-n+

Paga 12 of 24 Ohio EPA Permit No. 3IB00016*ED PART Ill - GENERAL CotDITlous (continued) 6.

J R CORDING OF RESULTS For each measurement or sanple taken pursuant to the requirements of this permit, the permittee shall record the following information:

A.

The exact place and date of aanpling; (time of sampling not required on EPA 4500)

B.

The person (s) who performed the sampling or measurements; C.

The date the analyses were performed on those sanples?

D.

The person (s) who performed the analyses; E.

The analytical techniques or methods used; and F.

The results of all analyses and measurements.

I T.

RECORDS RETENTION The permittee shall retain all of the following records for the wastewater treatment works for a minimun of th; n years, including:

A.

All sanpling and analytical records (including internal sanpling data not reported);

B.

All original recordings for any continuous monitoring instrumentation; C.

Att instrunentation, calibration and maintenance records; D.

Att plant operation and maintenance records; E.

All reports required by this permit; and F.

Records of att data used to complete the application for this permit for a period of at least three years from the date of the sanpte, measurement, report, or application.

j These periods will be extended during the course of any unresolved litigation, or when requested by the I

Regional Achinistrator or the Ohio EPA. The three year period for retention of records shalt start from the date of sarnple, measurement, report, or application.

8.

AJA_lLABILITY CF REPORTS Except for data determined by the Ohio EPA to be entitled to confidentist status, all reports prepared in accordance with the terms of this permit shall be available for public (nspection at the appropriate district offices of the Ohio EPA. Both the Clean Water Act and Section 6111.05 Ohio Revised Code state that ef fluent v

data and receiving water quality data shall not be considered confidential. Knowingly making any false statemnt on any such report may result in the inposition of criminal penalties as provided for in Ohio Revised Code Section 6111.99.

9.

DUTf TO PROVfDE INFORMAfl0N The permittee shall furnish to the Director, within a reasonable time, any information which the Director may request to determine whether cause exists for modifying, revoking, and reissuing, or terminating the permit, or to determine conpliance with this permit. The permittee shalt also furnish to the Director, upon request, copies of records required to be kept by this permit.

8 10.

RIGHT OF ENTRY The perniittee shall attow the Director or an authorized representative toon presentation of credentists and other docunents as may be required by (sw to; A.

Enterr upon the permittee's premises where a regulated feellity or activity is located or conducted, or where records must be kept urder the conditions of this permit.

j 8.

Have access to and copy, at reasonable times, any records that must be kept under the conditions of the permit.

C.

Inspect at reasonable times any facilities equipment (including monitoring and control equipment),

practices,oroperationsregulatedorrequ!reaunderthispermit.

D.

Sanple or monitor at reasonable times, for the purposes of assuring permit compliance or as otherwise author f red by the Clean Water Act, any s@ stances or parameters at any location.

11.

U4 AUTHORIZED DISCHARGES A

Bypassing or diverting of wastewater from the treatment works is prohibited unless:

1 Bypass was unavoidable to prevent loss of life, personal injury, or severe property damage; Form EPA 4428

~

l PIga 13 of 24 Ohio EPA Permit No. 3IB00016*ED l

PART III. a m aas CM SITImts (continued) 1 2.

There were no feasible alternatives to the bypass, such as tN, use of auxiliary treatment facilities retention of untreated wastes, or maintenance during normal periods of downtime. This conditionIsnotsatisfiedifadequatebackupequipmentshouldhavebeeninstalledintheexercise of reasonable engineering judgment to prevent a bypess which occurred during normal periods of i

equipment downtime or preventive maintenance; and

{

3.

The permittee submitted notices as required mder paragraph D. of thle section.

i B.

If the permittee knows in advance of the need for a bypass, it shall sthmit prior notice, if possible at j

least ten days before the date of the bypass.

C.

The Director may approve en unanticipated bypass after considering its adverse effects, if the Director i

determinesthatithasmetthethreeconditions((stedinparagraph11.A.ofthissection.

i D.

The permittee shall submit notice of an unanticipated bypass as required in section 12.

E.

The permittee may allow any bypass to occur which does not cause effluent limitatiens to be exceeded if that bypass is for essential maintenance to assure efficient operation.

j 12.

WONCOMPLIANCE NOTIFICATION l

A.

The permittee shall by telephone report any of the following within tusnty-four (24) hours of discovery at (toll free) 1-800-262 9378:

1.

Any nonenspliance which may endanger health or the environment; 2.

Any unanticipated bypass which exceeds any effluent limitation in the permit; or 3.

Any upset which exceeds any effluent limitation in the permit.

4 Any violation of a maxinun daily discharge limitation for any of the pollutants listed by the Director in the permit.

B.

For the telephone reports required by Part 12.A., the following information smaet be included:

3 1.

The times at which the discharge occurred, and was discovered; 2.

The approximate amount and the characteristics of the discharge; 3.

The stream (s) affected by the discharge; 4

The ciretsnstances which created the discharge; 5.

The names and telephone nLabers of the persons who have knowledge of these ciretsastances; 6.

What remedial steps are being taken; and l

7.

The names and telephone r:abers of the persons responsible for such remedial steps.

C.

These telephone reports shall be confirmed in writing within five days of the discharge and submitted to the appropriate Ohio EPA district office. The report shlt include the following:

1.

The limitation (s) which has been exceeded; 1

2.

The extent of the exceedence(?);

3.

The cause of the exceedance(s);

4.

The period of the exceedence(s) including exact dates and times; 5.

If uncorrected, the anticipated time the exceedence(s) is expected to continue, and 6.

Steps being taken to reduce, eliminate, and/or prevent recurrence of the exceedence(s).

D.

Conpliance Schedule Events:

If the permittee is unable to meet any date for achieving an event, as specified in the schedule of compliance, the permittee shall stheit a written report to the appropriate district office of the Ohio EPA within 14 days of brcoming aware of such situation. The report shall include the following:

1.

The compliance event which has been or will be violated; 2.

The cause of the violation; 3.

The remedial action being taken;,

4.

The probable date by which compliance will occur; and Form EPA 4428

}

l f

Paga 14 of 24 Ohio EPA Permit No. 3IB00016*ED PART III armseM Ctm lTIONS (centinued) 5.

The proonbility of complying with sesequent and final events as scheduled.

E.

The permittee shall report all instances of noncompliance not reported under paragraphs A, g, or C of this section, at the time monitoring reports are s@ mittsd. The reports shalt t atain the information listed in paragraphs e and C of this section.

F.

Where the permittee becomes aware that it failed to se mit any relevant application or submitted incorrect information in a such f acts or information. permit application or in any report to the director, it shall promptly semit 13.

RESERVED 14.

DUTY TO MlllGATE The permittee shall take all reasonable steps to minimize or prevent any discharge in vlotation of this permit which has a reasonable likelihood of adversely affecting hiamen health or the envirorument.

15.

AUTHORIZED DISCHARGES All discharges authorized herein shall be consistent with the terms and conditions of this permit. The discharge of any pollutant identified in this permit more frequently then, or at a tevel in excess of, hthat authorized by this permit shall constitute a violation of the terms and conditions of this permit. Suc violations may result in the imposition of civil and/or criminal penettles as provided for in Section 309 of the Act and Ohio Revised code sections 6111.09 and 6111.99.

16.

DISCHARGE CHANGES The following changes must be reported to the appropriate Ohio EPA district office as soon as practicable.

A.

For att treatment works, any significant change in character of the discharge which the permittee knows or has reason to believe has occurrect or will occur which would constitute cause for modification or revocation and reissuance. The peraf tree shall give advance notice to the Director of any planned changes in the permitted f acility or activity which may result in noncompliance with perett requirements.

Notification of permit changes or anticipated noncompliance does not stay any permit condition.

g.

For publicly owned treatment works:

1.

Any proposed plant modification, addition, and/or expension that will change the capacity or efficiency of the plant; 2.

The addition of any new significant industrial discharge; and Changes in the quantity or quality of the wastes from existi tributary industrial discharges which 3.

willresultinsignificantneworincreaseddischargesofpoNutants.

C.

For non publicly owned treatment works any proposed facility expensions, production increases, or processmodifications,whichwillresultinnow,different,orincreaseddischargesofpollutants.

Following this notice, modifications to the permit may be made to reflect any necessary changes in permit conditions, including any necessary effluent limitations for any pollutants not identified and limited herein. A determination ullt also be made as to whether e National Envirorwiental Policy Act (NEPA) review will be required. Sections 6111.44 and 6111.45, ohto Revised Code, rewire that plans for i

treatment works or improvements to such works be approved by the Director of the Ohio EPA prior to initiation of construction.

D.

In addition to the reporting requirements wider 40 CFR 122.41(1) and per 40 CFR 122.42(o), all existing manuf acturing, comunercial mining, and silviculturet dischargers must notify the Director as soon as they knoworhavereasontobelievet 1.

That any activity has occurred or will occur which would result in the discharge on a routine or frequent bests of any toxic pollutant which is not limited in the permit. If that discharee will exceed the highest of the " notification levels" specified in 40 CFR Sections 122.42(a)(1)(T) through 122.42(a)(1)(lv).

That any activity has occurred or will occur which would result in any discharge, hat discharge will 2.

on a non-routine or infrequent basis, of a toxic pollutant which is not limited in the permit, if t exceed the highest of the " notification levets" specified in 122.42(a)(2)(l) through 122.42(a)(2)(iv).

17.

Toxic POLLt M Il l

The permittee shall comply with effluent standards or prohibitions established under Section 307 (a) of the Clean Water Act for toxic pollutants within the time provided in the regulations that establish these standards er prohibitions even if the permit has not yet been modified to incorporate the requirement. Following establishmentofsuchstandardsorprohibitions,theDirectorshallmodifythispermitandsonotifythe permittee.

Form EPA 4428

-- -- -~-

Page 15 of 24 Ohio EPA Permit No. 3IB00016*ED PART Ill - ENERAL COWITI(uls (continued) 18.

PERMIT MODIFICAT10N OR REVOCATION a

Af ter notice and opportur)ity for a hearing, including, but not limited to, the following:this permit may be modified or revoked A.

whole or in port during its term for cause 1.

violation of any terms or conditions of this permit; 2.

obtaining this permit by misrepresentation or failure to disclose fully all relevant facts; or 4

3.

change in any condition that requires either a temporary or pennenent reduction or elimination of the permitted discharge.

the permittee may at any time apply to the Ohio g.

Pursuant to rule 3745 33-06, ohto Administrative code, filing of a request by the permittee for a permit EPA for modificition of any part of this permit.

The modification or revocation does not stay any permit condition. The application for modification should be received by the appropriate Ohio EPA district office at least ninety days before the date on which it is desired that the modification become effective. The application shall ne made only on forms approved by the Ohio EPA.

19.

TRANSFER OF OWNERSHIP OR CONTROL This permit cannot be transferred or assigned nor shalt a new owner or successor be authorized to discharge l

from this facility, until the following requirements are met:

A.

The permittee shalt notify the succeeding owner or successor of the existence of this permit by a letter, a copy of which shall be forwarded to the appropriate Ohio EPA district office. The copy of that letter will serve as the permittee's notice to the Director of the proposed transfer. The copy of that letter shall be received by the appropriate Ohio EPA district office sixty days prior to the proposed date of transfer; a

g.

A written agreement containing a specific date for transfer of permit responsibility and coverage between the current and new permittee (including acknowledgement that the existing permittee is liable for violations up to that date,iate Ohio EPA district office within sixty days, after receipt by the district and that the new permittee is liable for violations from that date on) shall be submitted to the appropr office of the copy of the letter from the permittee to the succeeding owner; C.

The Director does not exercise his right within thirty days after receipt of the written agreement to notify the current permittee and the new permittee of his or her intent to modify or revoke the permit and to require that a new application be filed; and D.

The new owner or successor receives written confirmation ano approval of the transfer from the Director of the Ohio EPA.

l At anytime during the sixty (60) day period between notification of the proposed transfer and the effective date of the transfer, the Director may prevent the transfer if he concludes that such transfer will jeopardize conpliance with the terms and conditions of the permit.

20.

0!L AND HAZARDOUS SUgSTANCE LIAgILITY i

Nothing in this permit shall be construed to preclude the institution of any legal action er relieve the S

permittee from any responsibilities, Liabilities, or penalties to which the permittee is or may be subject under Section 311 of the Act.

l i

29.

SOLIDS DISPOSAL i

Collected screenings, sturries, sludges, and other solids shall be disposed of in such a manner as to prevent entry of those wastes into waters of the state. For p elicly owned treatment works, these shall be disposed of in accordance with the approved Ohio EPA Sludge Management Plan.

23.

GAN,IJJUffl0N AFFECTING NAVIGAglE WATERS This permit does not authorize or approve the construction of any onshore or offshore physical structures or facilities or the undertaking of any work in any navigable waters.

23.

CIVIL AND rRIMINAL LI AgillTY

)

Except es exospted in the permit conditions on UNAUTHORIZED DISCNARGES or UPSETS, nothing in this permit shall be construed to relieve the permittee from civil or criminal penettles for noncompliance.

26.

STATE LAWS AND REGULAfl0NS Nothing in this permit shall be construed to preclude the institution of any legal action nor relieve the permittee from any responsibilities, liabilities, or penalties established pursuant to any applicable state law or reputstion trKier authority preserved by Section 510 of the Act.

Form EPA 4428

-f v

i

Page 16 of 24 Ohio EPA Permit No. 3IB00016*ED U

PART III - EEMERAL CEESITIONS (contfrued) 25.

PROPERTY RIGHTS The issuance of this permit does not convey any property rights in either rest or personal property, or any exclusive privileges, nor does it authorite any injury to private property or any invasion of personal rights, nor any infringement of federal, state, or local laws or regulations.

26.

ERT, The provisions of 40 CFR Section 122.41(n), relating to " Upset," are specifically incorporated herein by reference in their entirety. For definition of " @ set," see Part 1, DEFINITIONS.

27.

SEVERAsit1TY The provisions of this permit are severable, and if any provision of this permit, or the application of any provision of this permit to any circunstance,it, shall not be effected thereby.is held invalid, the application of such provisio circunstances, and the remainder of this perm 28.

SIGNATORY REQUIREMENTS All applications submitted to the Director shall be signed and certified in accordance with the requirements of 40 CFR 122.22(b) and (c).

1 All reports submitted to the Director shall be signed and certified in &ccordance with the requirements of 40 CFR Section 122.22(b) and (c).

29.

OTHER INFORMAtl0N A.

Where the permittee becomes aware that it failed to sLhmit any relevant facts in a permit application or submitted incorrect information in a permit application or in any report to the Director, it shall promptly submit such facts or information.

B.

ORC 6111.99 provides that any person who f alsifies, tanpers with, or knowingly renders inaccurate any monitoring device or method required to be maintained under this permit shall, @ on conviction, be punished by a fine of not more than $25,000 per violation.

C.

ORC 6111.99 states that any person who knowingly makes any false statement, representation, or certification in any record or other document submitted or required to be maintained mder this permit including monitoring reports or reports of compliance or nonconpliance shall, won conviction, be punished by a fine of not more than $25,000 per violation.

D.

ORC 6111.99 provides that any, person who violates Sections 6111.04, 6111.042., 6111.05., or division (A) of Section 6111.07 of the Revised Code shall be fined not more than twenty-five thousand dollars or inprisoned not more than one year, or both.

30.

NEED 70 MALT OR REDUCE ACTiv!TY 40 CFR 122.41(c) states that it shall not be a defense for a permittee in an enforcement action that it would have been necessary to halt or reduce the permitted activity in order to maintain compliance with conditions of this permit.

31.

APPLICABLE FEDERAL RULES All references to 40 CFR in this permit mean the version of 40 CFR which is effective as of the effective date of this permit.

i Form EPA 4428

Paga 17 of 24 Ohio EPA Permit No. 3IB00016*ED Part IV. STORM WATER POLLUTION PREVENTION PLMS A storm water pollution prevention plan (plan) shall be developed to a&fress each outf all that discharges to waters of the state that contains storm water associated with industrial activity. Storm water pottution prevention plans shtll t,e prepared in accordance with good engineering practices. The plan shall identify potentist sources of poliu:fon which may reasonably be expected to affect the quality of storm water discharges associated with industrial activity from the facility. In sodition, the plan shall describe and ensure the implementation of pecctices which are to be used to reduce the pollutants in storm water discharges associated with inaustrial cctivity at the f acility and to assure cogliance with the terms and conditions of this permit. Facilities must i

,t laplement the provisions of the storm water pollution prevention plan ragired under this part as a condition of I

this permit.

1 I

A.

Daedtinas for Plan Preparation and Cagliance.

1.

The plan for a storm water discharge associated with industrist activity:

a.

shall be prepared within six months of the effective date of this permit (and updated as appropriate);

b.

shall provice for i glamentation and cog liance with the terms of the plan within twelve months of the effective date of this permit.

2.

Upon a showing of good cause, the Director may establish a later date for preparing and cogliance with a plan for a storm water discharge associated with industrial activity.

B.

Signature and Plan Review.

1 The plan shall be signed in accordance with Part VI, and be retained on-site at the facility which generates the storm water discharge.

2.

The permittee shall make plans available upon request to the Ohio EPA Director, or authorized with hdustria{ or Regional Administrator of U.S. EPA, or in the case of a storm water discharge associated representative l

activity which discharges through a nnJnicipal separate storm sewer system, to the operator of the municipal system.

~

3.

The Director may notify the permittee at any time that the plan does not meet one or more of the mininun requirements of this Part. Within 30 days of such notification from the Director the permittee shalt make therequiredchangestotheplanandshallsubmittotheDirectorawrittencertiIlcationthattherequested changes have been made.

4.

All storm water pollution prevention plans required mder this permit are considered reports that shall be i

available to the public under Section 303(b) of the Act. The permittee may choose to fulfill such requests by allowing viewing of the plan at its f acilities, or choosing to copy the plan and sending it to the party l

making the request. The permittee may charge the party making the request a reasonable fee for copying the plan. The permittee may claim any portion of a storm water pollution plan as confidential in accordance with 40 CFR Part 2 and does not have to release any portion of the plan describing facility security measures (such as provided for in Part IV.D.7.b.(8) of this permit).

C.

Keeping Plans Current.

I The permittee shall amend the plan whenever there is a change in design, construction, operation or maintenance,thathasasignificanteffectonthepotentialforthedischargeofpollutantstot$ewatersofthe State or if the storm water pollution prevention plan proves to be ineffective in eliminating or significantly minimizing pollutants from sources identified m der Part IV.D.2 of this permit, or otherwise achieving the q

general objectives of controlling pollutants in storm water discharges associated with industrist activity.

Amensnents to the plan may be reviewed by Chlo EPA in the same manner as Part IV.8 above.

D.

Cantants of Plan. The plan shall include, at a mininun, the following items:

1.

Pollution Prevention Team Each plan shalt identify a specific individual or individuals within the f acility organization as mentiers of a storm water Pollution Prevention Team that are responsible for developing the storm water pollution prevention plan and assisting the facility or plant manager in its implementation, maintenance, and revision. The plan shall clearly identify the responsibilities of each team mentier. The activities and responsibilities of the team shall address all aspects of the facility's storm water pollution prevention plan.

2.

Description of Potential Pollutant Sources. Each plan shall provide a description of potential sources which may reasonably be expected to add significant amomts of pollutants to storm water discharges or which may result in the discharge of pollutants dJrity dry weather from separate storm sewers draining the facility. Each plan shall identify all activities and significant materials which may potentially be significant pollutant sources. Each plan shalt include, et a minlaun:

a.

Drainage.

(1) A site map indicating an outline of the drainage area of each storm water outfall, each existing structural control measure to radJee pollutants in storm water rmoff, surf ace water bodies, ills locations where significant materiets are exposed to precipitation, locations where major sp or leaks identified mder Part IV.D.2.c of this permit have occurred an followingactivitieswheresuchactivitiesareexposedtoprecipitatlon:dthelocationsofthe fueling stations, vehicle Fonn EPA 44 2 8 j

I i

Page 18 of 24 1

Ohio EPA Permit No. 3IB00016*ED 1

Part IV. 5701g1 nunTER POLLUTION PREVENTION PLANS (continued)

D.

(continued)

I and equipment maintenance and/or cleaning areas, loading / unloading areas, locations used for the treatment, storage or disposet of wastes, liquid storage tanks, processing areas and storage areas.

(2) For each area of the facility that senerates storm water discharges associated with industrict i

activity with a reasonable potential for containing significent asomts of pollutants, a prediction of the direction of flow, and an estimate of the types of pottutants which are likely to be present in storm water discharges associated with industrial activity. Flows with a significant potentist for causing erosion shall be identified.

b.

Inventory of Exposed Materials. An inventory of the types of meteriets handled at the site that potentistly may be exposed to precipitation. Such inventory shall include a narrative description of significant meterials that have been handled, treated, stored or disposed in a menner to allow exposure to storm water between the time of three years prior to the date of the issuance of this perm t and the present; method and location of on-site storage or disposal; meteriets a ---_.

minimize contact of materiets with storm water runoff netween the time of tEroe.t practices employed to years prior to the date of the issuance of this permit and the present; llutants in storm water runoff; and a description of any the location and a description of existing structural and non-structural control measures to reduce po l

treatment the storm water receives.

1 i

c.

Spills and Leeks. A list of significant spills and significant leaks of toxic or hazardous pollutants that occurred at the facility after the date of three years prior to the effective date of this permit.

d.

Sagling Data. A s!Junary of existing discharge sagting date describing pollutants in storm water discharges from the facility.

i e.

Risk Identification and Sumnery of Potentist Pollutant Sources. A narrative description of the potential pollutant sources at the following areas:

activities; outdoor manufacturing or processing activities;iption shall specifically lis outdoor storage significant dust or port 4

processes; and on-site waste disposal practices. The descr significant potential source cd pollutants at the site and for each pctential source, any pollutant or 4

pollutant parameter (e.g. biochenical oxygen demand, etc.) of concerns shall be identified.

3.

Measures and Controls. Each facility covered by this permit shall develop a description of storm water a

management controls appropriate for the incility, and inplement. such controls. The appropriateness and priorities of controls in a plan shall reflect identified potential sources of pollutants at the facility.

The description of storm water management controls shalt address the following minimun components, including a schedute for implementing such controts:

a.

Good Housekeeping Good housekeeping requires the maintenance of a clean, orderly facility, b.

Preventive Maintenance - A preventive maintenance program shall involve inspection and maintenance of storm water rer -

-.t devices (e.g. cleaning all/ water separators catch tolns) as well as inspecting and testing faclIity equipocat and systems to mcover conditions tbet could cause breakdowns or faltures resulting in discharges of pollutants to surface waters, and ensuring appropriate maintenance of such equipment and systems.

Spill Prevention and Response Procedures - Areas where potantial spills can occur, ion prevention plan.

and their c.

accompanying drainage points shall be identified clearly in the storin water pollut Where appropriate, specifying meterial handling procedures, storage requirements and use of equipment such as diversion valves in the plan should be considered. PrcceduresforcleanIngupspittsshallbe identified in the plan and made ovellable to the appropriate personnel. The necessary equipment to implement a clean to should be available to personnel.

d.

Inspections In addition to or as part of the comprehensive site evntuation required under Part IV.4.

of this permit, quellflod facility personnel shall be identified to inspect designated equipment and areas of the facility at appropriate intervals specified in the plan. A set of tracking or follow up records of inspections shall be maintained.ocedJres shall be used to ensure that appropriate actions are taken in response to W.

e.

E gtoyee Training Employee training programs shall inform personnel at att levels of responsibility of the components and goals of the storm water pollution prevention plan. Training should address topics such as spill response good housekeeping and material management practices. The plan shall identify periodicdetesforsucbtraining.

f.

Recordkeeping and Internal Reporting Procedures - A description of incidents such as 6 pills, or other discharges, along with other information describing the quality and quantity of storm wter discharges shalt be included in the plan required under this port. Inspections and maintenance activitle: shall be documented and records of such activities shall be incorporated into the plan.

g.

Non-Storm Water Discherpes (1) The plan shall include a certification that the discharge has been tested or evetusted for the presence of non-storm water discharges. The certification shall include the identification of potentist significant sources of non-storm water at the site, a description of the results of any i

Form EPA 4428

m._

W Page 19 of 24 Ohio EPA Pertnit No. 3IB00016*ED d

Part IV. SitWIIMTER POLLUTION PREVENTION PulNS (continusd) 4 D.

(continued) testand/orevaluationforthepresenceofnon-stormwaterdischarges$eonevaluationcriteriaor the testing method used, the date of any testing and/or evaluation, and t site drainage points that were directly observed during the test. Such certification may not be feasible if the 3'

facility operating the storm water discharge associated with industrial activity does not have access to an outfall, manhole, or other point of access to the ultimate conduit which receives the discharge. In such cases, the source identification section of the storm water pollution plan shall indicate why the certification required by this part was not feasible along with the identificationofpotentialsignificantsourcesofnon-stormwaterattheslte. A discharger that 4

is unable to provide the certification required by this paragraph aust notify in accordance with Part IV.A of this permit.

(2) Except for flows from fire fighting activities, sources of non-storm water listed in Part VI of this permit that are combined with storm water discharges associated with inAJstrial activity must be identified in the plan. The plan shall identify and ensure the Iglementation of appropriate pollution prevention measures for the non-storm water component (s) of the discharge.

t h.

Sediment and Erosion Control - The plan shall identify areas which, dae to topography, activities, or other factors, have a high potential for significant soll erosion, and identify measures to limit erosion.

a 3

1.

Management of Runoff - The plan shall contain a narrative consideration of the appropriateness of

^

traditional storm water management practices (practices other than those which control the source of pollutants)lutantsinstormwaterdisc$argesfromthesite.

used to divert, infiltrate reuse or otherwise manage store water rtmoff in a manner that reduces pol The plan shall provide that measures determined to be reasonable and appropriate shall be implemented and maintained. The potential of various sources at the facility to contribute pollutants to storm water discharges associated with industrial activity (see Parts IV.D.2.(b), (d) and (e) of this permit) shall be considered when determining reasonable and appropriate measures. Appropriate measures may include: including vegetative swales and practices, reuse of collected storm water (such as for a process or as an irrigation source),

intet controls (such as oll/ water separators), snow management activities, infiltration devices, and wet detention / retention devices.

i 4

Cogrehensive Site conpliance Evaluation. Qualified personnel shall conduct site compliance evaluations at appropriate intervals specified in the plan, but, except as provided in paragraph IV.D.4.d, In no case less than once a year. Such evaluations shall provide:

Material handling areas and other potential sources of pollution identified in the plan in accordance a.

with paragraph IV.D.2 of this permit shalt be visually inspected for evidence of, or the potential for, pollutants entering the drainage system. Structural storm water management measures sediment and controlmeasures,andotherstructuralpollutionpreventionmeasuresidentifiedintbeplanshallbe observed to ensure that they are operating correctly. A visual inspection of equipment needed to implement the plan, such as spill response equipment, shall be made, b.

Based on the results of the inspection,2 of this permit and pollution prevention measures and controlsthe descrip plan in accordance with paragraph IV.D.

identified in the plan in accordance with paragraph IV.D.3 of this permit shall be revised as i'

appropriate within two weeks of such inspection and shall provide for inplementation of any changes to the plan in a timely manner, but in no case more than twelve weeks af ter the inspection, h

c.

A report suunarizing the scope of the inspection, personnel making the inspection, the date(s) of the inspection, major observations relating to the inplementation of the storm water pollution prevention plan, and actions taken in accordance with paragraph IV.D.4.b of the permit shall be made and retained as part of the storm water pollution prevention plan for at least three years. The report shall be signed in accordance with Part VI.B of this permit.

5.

Additional requirements for storm water discharges associated with industrial activity through municipal separate storm sewer systems serving a population of 100,000 or more.

in addition to the applicable requirements of this permit, facilities covered by this permit aust comply I

with applicable requtrements in aunicipal storm water management programs developed tmder NPDES permits issued for the dischtrge of the municipal separate storm sewer system that receives the facility's discharge, provided the discharger has been notified of such conditions.

6.

Consistency with other plans. Storm water pollution prevention plans may reflect requirements for Spill Prevention Control and Countermeasure (SPCC) plans developed for the facility under section 311 of the Act i

or Best Management Practices (gMP) Programs otherwise required by a WPDES permit for the facility as long as such requirement is incorporated into the storm water pollution prevention plan.

i 7.

Additional requirements for storm water discharges associated with industrial activity from facilities subject to SARA Title III, Section 313 re wirements. In addition to the re w irements of Parts IV.D.1 through 4 of this permit and other applicable conditions of this permit storm water pollution prevention plans for facilities subject to reporting requirements under SARA Title,III, Section 313 for chemicals which are classified as "Section 313 water priority chemicals" in accordance with the definition in Part VI of this permit, shall describe and ensure the implementation of practices which are necessary to provide for conformance with the following guidelines:

1 Form EPA 4428 4

A J

m _ m. _. - _._._ _ _ _ _ _._ _

a 4

l Prga 20 of 24 Ohio EPA Permit No. 3IB00016*ED l

l 1

l Port IV. 57121 WhTEg POLLilTI M PgEVEllTIM PLAIBS (continued) l D.

(continued)

I a.

In areas where section 313 water priority chemicals are stored, processed or otherwise handled, appropriate conteirnent drainese control and/or diversionary structures shall be provided. At a minimisa, one of the fol,owing preventive systems or its equivalent shall be used:

l j

(1)

Curbi culverting, gutters, sewers or other forms of drainese control to prevent or minimize the potenbt for stors water re-on to come into contact with slystficent sources of pottutents; or e

1 (2) goofs, covers or other forms of appropriate protection to prevent storage piles from exposure to storm water, and wind blowing.

4 b.

In addition to the minimum standards listed under Part IV.D.7.e of this permit, the stors water pollution prevention plan shalt include a complete discussion of measures taken to conform with the i

following applicable guidelines other effective storm water pollution prevention procedures, and

{

applicablestaterules,regulatlonsandguidelines:

i (1)

Liquid storage areas where storm water comes into contact with any equipment, tank, container, j

or other vesset used for section 313 water priority chemicats.

(a) No tank or container shall be used for the storage of a section 313 water priority l

chemical mless its meteriet and construction are compatible with the meteriet stored and conditions of storage such as pressure and temperature, etc.

(b) Ligald storage areas for section 313 water priority chemicats shall be operated to i

minimize discharges of section 313 chemicals. Appropriate measures to minimize dischartes of section 313 chemicals may include secondary conteirunent provided for at least the entire contents of the largest single tank plus sufficient freeboard to allow for precipitetton, e strong spill contingency and integrity testing plan, and/or other equivalent measures.

(2)

Materiet storage areas for section 313 water priority chemicals other than liquids. Meterlat 1

storage areas for section 313 water priority chemicals other than tiquids which are s eject to runoff teaching, or wind blowing shalt incorporate drainese or other control features which willalnimizethedischargeofsection313waterprioritychemicalsbyredacingstormwater i

a contact with Section 313 water priority chemicals.

(3) truck and raf t car loading and mioeding areas for li id section 313 water priority chemicals.

1

' Truck and rail car loading and untoeding areas for ti id section 313 water priority chemicals shall be operated to minimize discharges of section 3 water priority chemicals. Appropriate measures to minimize discharges of section 313 chemicals may include: the placement and 1

maintenance of drip pens where spiltage may occur (such as hose connections, hose reels and i

filler nozzles) for use when maktng and breaking hose connections; a strong spilt contingency

]

and integrity testing plan; and/or other equivalent measures.

]

(4) l otherwisekandled.Processingequipmentandmaterfatshandlingequipmentshallbeoperatedso In facilit areas where section 313 water p:lorit chemicals are transferred processed or as to minimize discharges of section 313 water priority chemicals. Materiets used in piping and equipment shall be compettbte with the s estances handled. Drainese from process and

{-

materials handling erees shall be designed as described in peregraphs (a) blowing, spraying or (b) and (c) of this section. Additional protection such as covers or guards to prevent wind i

releases from pressure retlef vents from causing a discherpe of section 313 water priority a

4 chemicals to the drainage system, and overhangs or door sktrts to enclose trailer ends et truck toedine/ unloading docks shall be provided as appropriate. Visual inspections or teek tests shalt be provided for overhead piping conveying section 313 water priririty chemicals without secondary containment.

4 (5)

Discheroes from erees covered by peregraphs (1), (2), (3) or (4).

d (a) Drelnese from areas covered by peregraphs (1), (2), (3) or (4) of this part should be restrained by valves or other positive means to prevent the discnerge of a spilt or other excessive teskoge of section 313 meter priority chemicals. Wnere contatramnt units are y

suployed, such units may be emptied by ptaps or ejectors; however, these shall be manuelty activated.

1 (b)

FL r type drain volves shall not be used to drain utsteinment areas. Velves used for j

thNainese of contefrusent areas should, as for as is prectical, be of manuel, open-and-

]

closed design.

(c) If facility drainese is not engineered as above, the final discharge of alt in facility i

stor1a sewers shall be equipped to be equivalent with a diversion system that could, in the event of an econtrolled spill of Section 313 water priority chemicals, return the spilled meterial to the facility.

)

(d) Records shall be kept of the frequency and estimated volJoe (In gettons) of discherpes from containment areas.

1 1

j Forin EPA 4 4 28

Page 21 of 24 Ohio EPA Permit No. 3IB00016*ED a

Pzrt IV. STORM WER POLLtJTION PREVENTION PUWes (continued)

D.

(continued)

(6)

Facility site runoff other than from areas covered by (1), (2), (3) or (4). Other areas of the f acility (those not ackfressed in paragraphs (1), (2) from which rmoff which maycontainSection313waterprioritychemicatsorspills(3)or(4)),313waterpriority of Section chemicals could cause a discharge shall incorporate the necessary drainage or other control features to prevent discharge of spilled or inproperty disposed material and ensure the mitigation of pollutants in rmoff or teachate.

(7)

Preventive maintenance and housekeeping. Att areas of the facility shall be inspected at specific intervals for leaks or conditione that could lead to discharges of Section 313 water priority chemicals or direct contact of ', tors water with raw materials, intermediate materials, waste materiets or pro & cts. In parth.< ar facility piping,

, storage tanks and bins i

pressurevessels,processandmateriethandhneequipment, materialbulkstorageareas$all De examined for any conditions or failures which could tause a discharge. Inspection shall include examination for leaks wind blowing, corrosion, intervals shall be specified in the plan support or fomdation f ailure, or other i

forms of deterioration or non, containment.

Inspection and shall be based on design and rational experience.

Different areas may require l

i different inspection intervals, ere a leak or other condition is discovered which may result in significant releases of Section 313 water priority chemicals to the drainage system, corrective action shall be insendiately taken or the unit or process shut down mtit corrective action can be taken. When a leak or non containment of a section 313 Water priority chemical has occurred, contaminated soll, debris, or other material must be pronptly removed and disposed in accordance with Federal, State, and local requirements and as described in the plan.

(8)

Facility security. Facilities shall have the necessary security systems to prevent accidental or intentional entry which could cause a discharge. Security systems described in the plan shall address fencing, lighting, vehicular traffic controt, and securing of equipment and buildings.

(9)

Training. Facility employees and contractor personnel using the facility shall be trained in and informed of preventive measures at the facility. Employee training shalt be cordacted at intervsts specified in the plan, but not less than once per year, in matters of pollution control laws and regulations, and in the storm water poliution prevention plan and the particular features of the facility and its operation which are designed to minimize discharges of Section 313 water priority chemicats. The plan shall designate a person who is accountable for spill prevention at the f aellity and who will set up the necessary spill emergency procedures and reporting requirements so that spitts and emergency releases of Section 313 water priority chemicals can be isolated and contained before a discharge of a section 313 water priority chemical can occur. Contractor or temporary personnel shatI be informed of facility operation and design features in order to prevent discharges or spitts from occurring.

(10)

Engineering Certificaticn. No storm water pollution prevention plan for facilities sLbject to i

SARA Title III, Section 313 requirements for chemicals which are classified as 'Section 313 1

water priority chemicats' shall be effective to satisfy the requirements of part IV.D.7 of this permit unless it has been reviewed by a Registered Professional Engineer and certified to by such Professional Engineer. A Registered Professional Engineer shall recertify the plan every three years thereafter. By means of these certifications the engineer, having examined the facility and being familiar with the provisions of this part, shall attest that the storm water pollution prevention plan has been prepared in accordance with good engineering practices.

Such certifications shall in no way relieve the owner or operator of a facility covered by the l

plan of their duty to propere and fully inplement such plan.

8.

Additional Requirements for Salt Storage. Storage piles of satt used for delcing or other consaercial or industrial purposes and which generate a storm water discharge associated with industrial activity which is discharged to a waters of the United States shall be enclosed or covered to prevent exposure to precipitation,ffective date of this permit.except for exposure resulting from adding or removing materials from the pile within years of the e Piles do not need to be enclosed or covered where storm water from the pile is not discharged to waters of the State.

Form EPA 4428

Page 22 of 24 Ohio EPA Permit No. 3IB00016*ED s

l Part VI. OTNER STORM tmTER REeulREENTS, DEFlulTIONS Als AUTim!ZATicu j

A.

Failure to certify. Any facility that is temble to provide the certification recyJired under paragraph IV.D.3.g.(1) (testing for non-storm water discharges), must notify the Director within 180 days of the effective i

date of this permit. Such notification shall describe: the procedure of any test conducted for the presence of non stoem water discharges; the results of such test or other relevant observations; potential sources of non-storm water discharges to the storm sewer; and why adequate tests for such storm sewers were not feasible.

B.

Sipintory RespJirements. All storm water pollution prevention plans reports, certifications or inforination l

either suhaitted to the Director (and/or the operator of a large or,medita amicipal separate storm sewer system), or that this permit requires be maintained by the permittee, shall be signed, i

1.

a.

For a corporations by a responsible corporate officer. For the purpose of this section a responsible corporate officer means: (1) a president charge of a principal business function, secretary, treasurer, or vice-president of tbe corporation in making functions for the corporation; o, or any other person who performs similar policy or decision-r (2) the manager of one or more manufacturing, prodaction or i

eperating facilities em exceeding $25,000 000 (ploying more than 250 persons or having pross annual sales or expenditures ordelegatedtot$emanagerinaccordancewithcorporateprocedures;in second-quarter 1980 dollars) if authority to sig i

b.

For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or c.

For a municipality: State, Federal or other p stic agency: by either a principal executive officer or ranking elected official. For purpo,ses of this section, a principal executive officer of a Federal agency includes (1) the chief executive officer of the agency, or (2) a senior executive officer having responsibility for the overall operations of a principal geographie unit of the agency (e.g. Regional a

Achinistrators of EPA).

2.

All reports required by the permit and other information requested by the Director shall be signed by a person described above or by a duty authorized representative of that person. A person is a duty authorized representative only if:

l a.

The authorization is made in writing by a person described above and s@mitted to the Director.

b.

The authorization specifies either an individual or a position having responsibility for the overalt i

operationoftheregulatedfacilityoractivity,suchasthepositionofmanager\\tionhavingoveralt

operator, I

s werintendent,for environmental matters for the company. (A duty authorized representative may thus or position of equivalent responsibility or en individual or pos i

responsibility either a named individual or any individual ocr w ying a named position).

4 c.

Changes to authorization. If an authorization under paragraph VI.g.2. is no longer accurate because a dif ferent individual or position has responsibility for the overall operation of the facility, a new 1

i authorlFation satisfying the requirements of paragraph VI.g.2. must be submitted to the Director prior to or together with any reports, information, or applications to be signed by an authorized representative, d.

Certification. Any person signing documents tmder this section shall make the following certification:

"I certify under nonalty of law that this document and all attachments were orecared tmder av direction or supervision in accordance with a system desianed to assure that aunlified personnet oronerly nauhered 1

and evaluated the informat' on stemitted. W on av innuiry of the oerson or persons who T.r m uhe system. or those norsons d rectly resconstele for natherina the information. the information stantuted i

is, to the best o" av knowl edne and belief, true, accurate and conotate. I as aware uhat there are i

i ntficant penatutes for stem ttina false information, includInn the possibtLity of "ine and mor s vi mt for knowinn vio,aoions.=

j C.

Definitions.

e a

tl 313 water orfority chemical" means a chemical or chemical categories which are: 1) are listed at 40 CFR 3

pursuant to section 313 of Title III of the swerftmd Amendments and Reauthorization Act (SARA) of 1986 4

also titled the Emergency Planning and Conusmity Right to-Kr9w Act of 1986* 2) are present at or above thresho{d levels at a facility s 4Joct to SARA Title It! Section313reportingregulrements;and3)thatmeetatleast i

one of the followins criteria: (i)areListedinAppendixDof40CFR122oneitherTableII(organicpriority pollutants), Table III (certain metals, cyanidos, and phenots) or Table V (certain toxic pollutants and hazardous s 4 stances) 40 CFR 116.4; or (iii; are pollutants for which EPA has p elished acute or chronic water quality criteria.(ii) are liste

)

"Sinnificant materiets" includes, but is not limited to: raw materiets detergents, and plastic pettets; finished materiale such as metettic pr;odacts* raw materials used in foodfuels; materials such as solve processing or production; hazardous s@ stances designated tmder section 101(1D of CERCLA; any chemical the j

1 facility la required to report pursuant to Section 313 of Title Ill of SARA fertilizers; pesticides

  • and w 4

products such as ashes, slag and studge that have the potential to be releas:ed with stone water disc $arges.aste "1bnificant sollts" includes, but is not limited to: releases of oil or hazardous s@ stances in excess of i

~

reportabTe quantities smder section 311 of the clean Water Act (see 40 CFR 110.10 and CFR 117.21) or section 102 of CERCLA (see 40 CFR 302.4).

l a

1 Fom EPA 4428

1 Page 23 of 24 Ohio EPA Permit No. 3IB00016*ED l

Part VI. OTHER STORM WLTIR REQUIRDENTS, DEFINITIONS Ale AL;TWORIZATION (continued) 1 C.

(continued) l

" Storm Water" means storm water runoff, snow melt runoff, and surface runoff and drainage.

" Definition of Store Water Associated with Industriot Activity" means the discharge from any conveyance which is used for collecting and conveying storm water and which la directly related to manufacturing, processing or raw i

materials storage areas at en industrial plant. The term does not include discharges from facilities or activities excluded from the NPDES program. For the categories of industries identified in s @ paragraphs (i) through (x) of this subsection, the term incita$es, but is not limited to, storm water discharges from L dustrial l

plant yards; immediate access roads and rail lines used or traveled by carriers of raw materials, manufactured pro & cts, waste material, or by products used or created by the facility; material handling sites; refuse sites; sites used for the application or disposal of process waste waters (as defined at 40 CFR 401); sites used for the storage and maintenance of materlat handling equipment; sites used for residual treatment storage or disposal;shippingandreceivingareas;manufacturingbuildings;storageareas(includingtankfarms)lorraw materlats,ignificant materiets remain and are exposed to storm water.and intermediate and finished products; and areas where indus past W s For the categories of industries identified in subparagraph (xi), the ters includes only storm water discharges from all areas listed in the j

previws sentence (except access roads) where material handling owipment or activities, raw materials,d to interwliote products, final products, weste materials,iet handling activities include thetby-products, or industrist machinery are ex storm wd r,.

For the purposes of this paragraph, mater storage, loading and unloading, transportation,orconveyanceofanyrawmaterial(andsseparatefromtheplant'sindustrialby-product intermediate product, finished product or waste product. The term excludes areas located on plant activities, such as office buildings and accompanying parking lots as long as the drainage from the excluded areas is not mixed with storm water drained from the above described areas. In kstrial facilities (including industrint facilities that are Federall f acilities listed in this paragraph (i)y or nunicipally owned or operated that meet the description of the-(xi)) include those f acilities desi The fotlowing categories of facilities are considered to be engaging in "industrist activity" for purposes of this subsection:

(i)

Facilities subject to storm water effluent limitations guidelines, new source performance standards, or toxic pollutant ef fluent standards under 40 CFR Subchapter N (except f acilities with toxic pollutant ef fluent standards which are exenpted mder category (xi) of this paragraph);

(ii)

Facilities classified as Standard Industrial Classifications 24 (except 2434), 26 (except 265 and 267),

28 (except 283 and 285) 29, 311, 32 (except 323), 33, 3441, 373; (iii)

Facilities classified as Standard Industrial Classifications 10 through 14 (mineral indJstry) including active or inactive mining operations (except for areas of coal mining operations meeting the definition of a reclamation area under 40 CFR 434.11(l)) and oil and gas exploration, production, processing, or treatment operations, or transmission f acilities that discharge storm water contaminated by contact with or that has come into contact with, any overburden, raw material, intermediate products, finished products, byproducts or waste products located on the site of such ratio.)s; inactive mining operations are mining sites that are not being actively mined, but ich have an identifiable owner / operator; (iv)

Hazardous waste treatment, storage, or disposal facilities, including those that are operating under interim status or a permit under S@ title C of RCRA; Landfitts, land application sites l ties described mder this subsection)and open ckaps that have received any industrial waste (v) is received from any of the facil including those that are subject 1

to regulation under S@ title D of RCRA; (vi)

Facilities involved in the recycling of materials including metal scrapyards battery reclaimers, salvage yards, and automobile Jur.kyards, including, but not limited to those classified as Standard Industrial Classification 5015 and 5093; (vii)

Steam electric power generating facilities, including coal handling sites; i<iii) Transportation facilities classified as Standard Industrial Classifications 40, 41, 42 (except 4221 25),

43,44,45,and5171whichhavevehiclemaintenanceshops,equipmentcleaningoperationslclemaintenance or airport deicing operations. Only those portions of the facility that are either involved in veh (including vehicle rehabilitation mechanical repairs, painting, fueling and tubrication), equipment airportdelcIngoperations cleaningoperations,fthissubsectionareassoclstedwithindustristactivity;or which are otherwise Identified m (vil) or (ix)-(xi) o (ix)

Treatment works treating domestic sewage or any other sewage sludge or wastewater treatment device or system, used in the storage treatment, recycling, and reclamation of assitcipal or domestic sewage, including land dedicated to the disposal of sewage sludge that are located within the confines of the facility, with a design flow of 1.0 med or more, domestic gardens or lands used for studge managementor reguired to ha under 40 CFR 403. Not included are farm tends, where sludge is beneficially reused and which are not ph mically located in the confines of the facility, or areas that are in conpliance with 40 CFR 503; (x)

Construction activity - This category of industrial activity is not regulated under this permit.

Fonn EPA 4 4 2 8

g Page 24 of 24 Ohio EPA Permit No. 3IB00016*ED Part VI. OTHER SToppi IRTER REQUIRDENTS, DEFINITIONS Am AUTHORIZATION (continued)

C.

(continued)

(xi)

Facilities under standard Industrial Classifications 20, 21 37 (except 3h)2,38, 39, 4121-ES, (a,nd w$ich are not27, 283, 285, 2

23, 2434 25 265 267 30 31 (except 311), 34 (except 3441) 35 36 otberwiseincludedwithincategories(,ii),(x)),.

" WppP" means storm water pollution prevention plan to be coupleted as a condition of this permit (see Part lY t is permit).

o

" Time-weinhted composite" means a composite sample consisting of a mixture of equal volume aliquots collected at a constant time intervet.

"Weste elle" means any non-containerized accunulation of solid, non-flowing weste that is used for treatment or storage.

j

" h ar. 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> orecioltation event" means the maxinue 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> precipitation event with a probable reoccurrence intervat of once in 10 years. This information is avalleole in " Weather Bureau Technical Paper No.

40lm"a,ticCenteroftheEnvironmentalDataServiceMay 1961 and "NOAA Atlas 2," 1973 for the 11 Western states, and may be ob Cl

, National Oceanic and Atmospheric Artainistration, U.S.

Department of Consnerce.

"9.msn.t" means the intentional diversion of weste streams f rom any portion of the treatment f acility.

'TgLet" means an exceptional incident in which there is u11ntentional and tanporary nonconpliance with technology based permit effluent limitations because of factors beyond the reasonable control of the permittee.

An upset does not include nonconpliance to the extent caused by operational error, improperly designed treatment f acilities, iredequate treatment f acilities, lack of preventive maintenance, or careless or inproper operation.

1 Fortr EPA 4428