Discusses LER 96-017 Re Failure of Multiple SRVs to Open within Required TS Allowable Tolerance.Commitments Re LER Provided
Date released: 05/27/2020 Download: ML20134M081


:on 961025,multiple SRVs Settings Found Outside of One % Tolerance Allowance.Caused by corrosion-induced Bonding of Pilot Valve Disc & Seat.Replaced All 15 Cycle 5 Pilots W/Recertified & Refurbished Pilots
ML20134M097
Person / Time
Site: Fermi 
Issue date: 11/15/1996
From: Riches K
DETROIT EDISON CO.
To:
References
Download: ML20134M097 (8)
Discusses LER 96-017 Re Failure of Multiple SRVs to Open within Required TS Allowable Tolerance.Commitments Re LER Provided
ML20134M078
Person / Time
Site: Fermi 
Issue date: 11/15/1996
From: Gipson D
DETROIT EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
CON-NRC-96-0097, CON-NRC-96-97
Download: ML20134M078 (3)