Forwards FEMA Final Rept for 960724, Radiological Emergency Preparedness Medical & Relocation Ctr Drills Rept, for Comanche Peak Steam Electric Station.Rept Indicates No Deficiencies Identified During Drills
ML20134K914
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 11/14/1996
From: Gwynn T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Terry C
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
Shared Package
ML20134K917 List:
References
NUDOCS 9611200088
Download: ML20134K914 (4)


Text

_

9 f "' %,

UNITE D ST ATES te ft NUCLEAR REGULATORY COMMISSION

,.[./

REGloN IV 6'

E 611 RYAN PLAZA DRIVE. SUITE 400

  1. '4 AR LING ton, T E XAS 76011 8064 9....+

NOV I 41996 Mr. C. L. Terry TU Electric Group Vice President, Nuclear ATTN: Regulatory Aff airs Department P.O. Box 1002 Glen Rose, Texas 76043

SUBJECT:

FEDERAL EMERGENCY MANAGEMENT AGENCY'S REPORT

Dear Mr. Terry:

Enclosed is a copy of the Federal Emergency Management Agency's final report for the July 24,1996, Comanche Peak Steam Electric Station offsite medical and relocation center drills.

The report indicates that there were no deficiencies identified during the drills. One area requiring corrective action was identified during the relocation center drill. No response to the NRC is required.

If you have any questions concerning this letter, please contact Ms. Gail M. Good at (817)860-8215.

)

Sincerely,

% =20 Thomas P. Gwynn, Director Division of Reactor Safety

Enclosure:

As stated Docket Nos.: 50-445;50-446 License Nos.: NPF-87; NPF-89 i

l cc w/cnclosure:

l Mr. Roger D. Walker i

TU Electric Regulatory Affairs Manager P.O. Box 1002 Glen Rose, Texas 76043 9611200088 961114 PDR ADOCK 05000445 j

F PDR

i TU Electric l I

Juanita Ellis President - CASE -

1426 South Polk Street Dallas, Texas 75224 -

TU Electric-Bethesda Licensing 3 Metro Center, Suite 610 Bethesda, Maryland 20814 George L. Edgar, Esq.

Morgan, Lewis & Bockius 1800 M. Street, NW.

Washington, D.C. 20036 G. R. Bynog, Program Manager /

Chief Inspector

.-Texas Department of Licer' sing & Regulation Boiler Division P.O. Box 12157, Capitol Station Austin, Texas 78711 i

Honorable Dale McPherson County Judge P.O. Box 851 Glen Rose, Texas 76043 Texas Radiation Control Program Director I

1100 West 49th Street Austin, Texas 78756 Susan Rieff, Director l

Environmental Policy Office of the Governor _

- P.O.' Box 12428 i

Austin, Texas 78711 Chief, Technological Hazards Branch FEMA Region 6

]

Federal Regional Center 800 North Loop 288 Denton, Texas 76201-3698 4

r-1

[

TU Electric E-Mail report to D. Nelson (DJN)

E-Mail report to NRR Event Tracking System (IPAS) gbcc to DMB (IE35).

bec distrib. by RIV:

L. J. Callan Resident inspector (2)

DRP Director DRS-PSB Branch Chief (DRP/A)

MIS System Project Engineer (DRP/A)

RIV File Branch Chief (DRP/TSS)

Leah Tremper (OC/LFDCB, MS: TWFN 9E10)

T. Essig (NRR/DRPM/PERB)

C. A. Hackney, ORA i

I J

i i

DOCUMENT NAME: G:\\DRSLTRS\\FEMAMD96.CP To receive copy of document. Indicate in box: "C" = Copy wit,hout enclosures "E" = Copy with enclosures "N" = No copy SEPA:PSB E

C:PSB

,E D:DRSV jf l

GMGood:cg ($V BMurray fl TPGwynrQ l

11 Q96 11 @ 6 1143/96 V j

l OFFICIAL RECORD COPY I

?00011

1

>e i

t

[

l TU Electric i l

t E-Mail report to D. Nelson (DJN)

E-Mail report to NRR Event Tracking System (IPAS)

~

bec to DMB (IE35) bec distrib. by RIV:

j Resident inspector (2) 1 4

L. J. Callan j

DRP Director DRS-PSB I

Branch Chief (DRP/A)

MIS System

_ Project Engineer (DRP/A)

RIV File Branch Chief (DRP/TSS)

Leah Tremper (OC/LFDCB, MS: TWFN 9E10)

T. Essig (NRR/DRPM/PERB)

C. A. Hackney, ORA -

d 4

l 2

a DOCUMENT NAME: G:\\DRSLTRS\\FEMAMD96.CP To receive copy of document, Indicate in box: "C" = Copy wqat enclosures "E" = Copy with enclosures "N" = No copy SEPA:PSB -

E C:PSB E

D:DRSV J GMGood:cg ($V BMurray T TPGwynr@

I 114396 11@96 1143/96 V OFFICIAL RECORD COPY