SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT NO.219TO FACILITY OPERATING LICENSE NO. OPR-53 AND TO FACILITY OPERATING LICENSE NO. DPR-69 AMENDMENT NO.196 BALTIMORE GAS AND ELECTRIC COMPANY CALVERT CLIFFS NUCLEAR POWER PLANT. UNIT NOS. 1 AND 2 DOCKET NOS. 50-317 AND 50-318

1.0 INTRODUCTION

On September 12, 1995, the U.S. Nuclear Regulatory Commission (NRC) approved issuance of a revision to 10 CFR Part 50, Appendix J, " Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors" which was subsequently published in the Federal Reaister on September 26, 1995, and bec'.me effective on October 26, 1995. The NRC added Option B

" Performance-Based Requirements" to allow licensees to voluntarily replace the prescriptive testing requirements of 10 CFR Part 50, Appendix J, with testing requirements based on both overall leakage rate performance and the performance of individual components.

In Amendments No. 212 to Facility Operating License No. DPR-53 and Amendment No. 189 to Facility Operating License No. DPR-69 for the Calvert Cliffs Nuclear Power Plant, Unit Nos. I and 2, respectively, the Technical Specifications (TSs) were revised to reflect the approval for the use of 10 CFR Part 50, Appendix J, Option B, for the containment leakage rate test program for Type A test only.

By application dated November 26, 1996, the Baltimore Gas and Electric Company (the licensee, ~BGE) requested changes to the TSs for the Calvert Cliffs Nuclear Power Plant, Unit Nos. I and 2.

The proposed changes will adopt Option B of 10 CFR Part 50, Appendix J, to require Type B and C containment leakage rate testing to be performed on a performance-based testing schedule.

In Amendment Nos. 212 and 189, the licensee established a Containment Leakage Rate Testing Program and added the program to the TSs. The licensee proposes to revise the program for Type A testing to additionally implement Types B and C testing of the containment as required by 10 CFR 50.54(o) and 10 CFR Part 50, Appendix J, 9ption B.

The program references Regulatory Guide (RG) 1.163, " Performance-Based Containment Leak Test Program," dated September 1995, which specifies a method acceptable to the NRC for complying with Option B.

9702140207 970211 PDR ADOCK 05000317 P

PDR

m o

n.

i 1 I i

1

2.0 BACKGROUND

Compliance with 10 CFR Part 50, Appendix J, provides assurance that the l

primary containment, including those systems and components which penetrate the primary containment, do not exceed the allowable leakage i

rate specified in the TS and Bases. The allowable leakage rate is determined so that the leakage assumed in the safety analyses is not l

exceeded.

On February 4,1992, the NRC published a notice in the Federal Reaister 4

(57 FR 4166) discussing a planned initiative to begin eliminating i

requirements marginal to safety which impose a significant regulatory burden. Appendix J of 10 CFR Part 50 was considered for this initiative i

and the staff undertook a study of possible changes to this regulation.

The study examined the previous performance history of domestic i

containments and examined the effect on risk of a revision to the requirements of Appendix J.

The results of this study are reported in l

NUREG-1493, " Performance-Based Leak-Test Program."

l i

Based on the results of this study, the staff developed a performance-j based approach to containment leakage rate testing. On September 12, 1995, the NRC approved issuance of this revision to 10 CFR Part 50, Appendix J, which was subsequently published in the Federal Register on September 26, 1995, and became effective on October 26, 1995.

The revision added Option B " Performance-Based Requirements" to Appendix J to i

allow licensees to voluntarily replace the prescriptive testing requirements of Appendix J with testing requirements based on both overall and individual component leakage rate performance.

Regulatory Guide (RG) 1.163, was developed as a method acceptable to the NRC staff for implementing Option B.

This regulatory guide states that i

the Nuclear Energy Institute (NEI) guidance document NEI 94-01, Rev. O,

" Industry Guideline for Implementing Performance-Based Option of 10 CFR Part 50, Appendix J" provides methods acceptable to the NRC staff for complying with Option B with four exceptions which are described therein.

1 Option B requires that the RG or other implementation document used by a licensee to develop a performance-based leakage rate testing program must i

be included, by general reference, in the plant TSs. The licensee has referenced RG 1.163 in the Calvert Cliffs TS.

l Regulatory Guide 1.163 specifies an extension in Type A test frequency to at least one test in 10 years based upon two consecutive successful tests. Type B tests may be extended up to a maximum interval of 10 years based upon completion of two consecutive successful tests and Type C tests may be extended up to 5 years based on.two consecutive successful tests.

By letter dated October 20, 1995, NEI proposed TS to implement Option B.

After some discussion, the NRC staff and NEI agreed on final TS which were attached to a' letter from C. Grimes (NRC) to D. Modeen (NEI) dated November 2, 1995. These TS are to serve as a model for licensees to

i

} 1 develop plant-specific TS in preparing amendment requests to implement Option B.

i For a licensee to determine the performance of each component, factors j

that are indicative of or affect performance, such as an administrative leakage limit, must be established. The administrative limit is selected J

to be indicative of the potential onset of component degradation.

Although these limits are subject to NRC inspection to assure that they i

are selected in a reasonable manner, they are not TS requirements.

Failure to meet an administrative limit requires the licensee to return to the minimum value of the test interval.

l l

Option B requires that the licensee maintain records to show that the l

criteria for Type A, B, and C tests have been met.

In addition, the i

i licensee must maintain comparisons of the performance of the overall containment system and the individual components to show that the test i

intervals are adequate. These records are subject to NRC inspection.

i 3.0 EVALUATION i

i The licensee's November 26, 1996, letter to the NRC proposes to revise the existing Containment Leakage Rate Testing Program for Type A testing i

to implement Types B and C testing of the containment as required by 10 CFR 50.54 (o) and 10 CFR Part 50, Appendix J, Option B, and proposes to i

make the changes to the TSs. The program references RG 1.163, which specifies a method acceptable to the NRC for complying with Option B.

j This requires a change to existing TS 3/4 6.1.1, 3/4 6.1.2, 3/4 6,1.3, i

3/4 9.8.1, and 6.5.6.

Corresponding Bases were also modified.

i Option B permits a licensee to base Type A or Type B and C; or Type A, B l

and C; testing to be done a performance bases. The licensee has elected j

to add Type B and C testing to the existing Containment Leakage Rate Testing Program, so as to perform Type A, B, and C testing on a performance basis.

i With the adoption of Option B, BGE will no longer require the exemption i

noted in the TS from the requirements of 10 CFR Part 50, Appendix J,

)

Paragraph III.D.2 and III.D.3 for both units, and it is BGE's intention to return to full compliance with 10 CFR Part 50, Appendix J.

Pursuant i

i to 10 CFR Part 50, Appendix J, Option B, paragraph V.B.1, this exemption j

is no longer applicable because it is not necessary.

The staff has reviewed these proposed changes, and concluded that, despite the different format of the licensee's current TSs, all the i

important elements of the guidance regarding Type B and C testing i

provided in the NRC letter to NEI are included in the TS proposed by the licensee, with one exception. The model TS spec.ify compliance with i

Option B "as modified by approved exemptions," but the licensee has j

closen not to include the quoted phrase. As the proposed TS is more conservative than the model TS in this case, the proposed TS is acceptable. Consequently, the staff finds that the proposed changes are in compliance with the requirements of Option B and consistent with the i

i

I i !

guidance of RG 1.163, and the model TS of the November 2,1995, letter and are, therefore, acceptable to the staff.

5 4.0 STAIE CONSULTATION i

In accordance with the Commission's regulations, the Maryland State official was notified of the proposed issuance of the amendment. The i

State official had no connents.

)

5.0 ENVIRONMENTAL CONSIDERATION

The amendment changes a requirement with respect to installation or use i

of a facility component located within the restricted area as defined in 10 CFR Part 20 and changes surveillance requirements. This also changes surveillance requirements. The NRC staff has determined that the amendment involves no significant increase in the amounts, and no significant change in the types, of any effluents that may be released i

offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. The Commission has previously issued a proposed finding that the amendment involves no l

significant hazards consideration, and there has been no public comment on such finding (62 FR 123). Accordingly, the amendment meets the

{1 eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9).

Pursuant to 10 CFR 51.22(b) no environmental impact statement or environmental assessment need be prepared in connection with l

the issuance of the amendment.

6.0 CONCLUSION

i.

The Commission has concluded, based on the considerations discussed l

above, that (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, i

(2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the

)

public.